5131V104-UK

2-WIRE PROGRAMMABLE

TRANSMITTER 5131

•  Input for RTD, TC, mV, linear resistance, mA, and V
•  3.75 kVAC galvanic isolation
•  4...20 mA loop output
•  1- and 2-channel versions
•  ATEX Ex version
•  DIN rail mounting

Application

Electronic temperature measurement with resistance sensor or thermocouple 

sensor.  •  Ex  barrier  for  temperature  sensors,  potentiometers  and  current  / 
voltage  signals.  •  Conversion  of  current  signals  from  supplied  transmitters  to 
2-wire  4...20  mA  signals.  •  Amplification  of  mV  signals.  •  Conversion  of  linear 
resistance  variation.  •  Galvanic  isolation  of  analogue  signals.  •  Measurement  of 
floating  signals.  •  Linearisation  of  non-linear  Ohm,  mV,  mA,  or  voltage  signals.

 

• Separation of circuits in PELV/SELV installations.

Technical characteristics

The unit is based on a microprocessor core with an efficient program operation. 
The basic calibration data and present set-up are stored in an EEPROM thereby 
avoiding the loss or change of data at power off. The 2-channel version has a full 
galvanic isolation between the channels. By way of a jumper on the PCB the input 
in the standard version can be programmed either for a temperature or a current / 
voltage input. This means that one channel can work as for instance a temperature 
transmitter and the other can work as an isolation amplifier. Measurement range, 
signal parameters, and output span are configured to the present task by way of a 
PC and PR electronics A/S’ communications interface Loop Link.

Input types

Temperature input - jumper in position 1:

Thermocouple input

 (TC) for standard thermocouples type B, E, J, K, L, N, R, S, T, 

U, W3, W5, LR according to the norms IEC 584, DIN 43710, ASTM E988-90 and 
GOST 3044-84.

Содержание 5131A

Страница 1: ...5 1 3 1 P r o g r a m m a b l e T r a n s m i t t e r N o 5 1 3 1 V 1 0 4 U K S e r n o 0 4 0 1 1 2 0 0 1 1 9 1 0 9 1 0 0 0...

Страница 2: ...electronics A S offre une large gamme de produits pour le traite ment des signaux analogiques et num riques dans tous les domaines industriels La gamme de produits s tend des transmetteurs de temp rat...

Страница 3: ...identification 3 Safety instructions 3 How to demont system 5000 5 Application 6 Technical characteristics 6 Input types 6 Output 7 Sensor error detection 7 Configuration 7 Electrical specifications 8...

Страница 4: ...rer the protection provided by the equipment may be impaired WARNING Until the device is fixed do not connect hazardous voltages to the device The following operations should only be carried out on a...

Страница 5: ...y regulations Operators being familiar with the contents of this manual adjust and operate the knobs or potentiometers during normal operation Receipt and unpacking Unpack the device without damaging...

Страница 6: ...ff the voltage to the device Production year can be taken from the first 2 digits of the serial number Calibration and Adjustment During calibration and adjustment the measuring and connection of exte...

Страница 7: ...rail as shown in picture 1 Then by lifting the upper lock and pulling the front plate simultaneously the PCB is removed as shown in picture 2 Switches and jumpers can now be adjusted By opening the fr...

Страница 8: ...aracteristics The unit is based on a microprocessor core with an efficient program operation The basic calibration data and present set up are stored in an EEPROM thereby avoiding the loss or change o...

Страница 9: ...Standard loop 4 20 mA current output The output signal is proportional and linear to the value of the input signal Special set ups can be selected in the configuration program for instance a customis...

Страница 10: ...rface Loop Link Signal noise ratio Min 60 dB 0 100 kHz Signal dynamics input 22 bit Signal dynamics output 16 bit Updating time Temperature input 115 ms mA V mV input 75 ms Response time 0 90 100 10 p...

Страница 11: ...109 x 23 5 x 130 mm DIN rail type DIN 46277 Protection degree IP20 Weight 195 g EMC immunity influence 0 5 of span Extended EMC immunity NAMUR NE 21 A criterion burst 1 of span Basic values Input type...

Страница 12: ...of sensor cable resistance 3 4 wire 0 002 Sensor error detection Yes Type Min value Max value Min span Standard Pt100 Ni100 Lin R 200 C 60 C 0 850 C 250 C 5000 25 C 25 C 30 IEC 751 DIN 43760 Type Min...

Страница 13: ...C Max offset 50 of selec max value Input resistance 2 5 VDC Nom 10 M 2 5 VDC Nom 5 M Electrical specifications OUTPUT Signal range span 4 20 mA Min signal range span 10 mA Max offset 50 of selec max v...

Страница 14: ...D 2006 95 EC EN 61010 1 PELV SELV IEC 364 4 41 and EN 60742 ATEX 94 9 EC EN 50014 EN 50020 and EN 50281 1 1 Of span Of the presently selected range Order Note For TC inputs with internal CJC remember...

Страница 15: ...Pt100 DIN IEC 0 00 50 00C 3 wire 1 00sec Inputrange C onnection C old junction comp Response time Tag no Disconnectwhen online loopcommunicationisused Loopcommunication Vsupp Black Red Yellow Green 4...

Страница 16: ...4 20 m A 0 16 m A 0 16 m A 53 5 M 52 Input Input 2 5 V Channel 2 Channel 1 mV TC Front comm Front comm RTD and lin R Conn wire Input gnd Analogue switch Analogue switch Accessories 5910 CJC connector...

Страница 17: ...lvanic isolators for analog and digital signals as well as HART signals A wide product range with both loop powered and universal isolators featuring linearization inversion and scaling of output sign...

Страница 18: ...it prelectronics com www prelectronics se sales se prelectronics com www prelectronics co uk sales uk prelectronics com www prelectronics com sales us prelectronics com www prelectronics cn sales cn...

Отзывы: