Display / programming front

TEMPER ATURE  |  I.S. INTERFACES  |  COMMUNIC ATION INTERFACES  |  MULTIFUNC TIONAL  |  ISOL ATION  |  DISPL AY

No. 4510V100-UK
From serial no.: 221207001

Содержание 4510

Страница 1: ... MADE SMARTER P E N D I N G P E N D I N G Product manual 4510 Display programming front TEMPERATURE I S INTERFACES COMMUNICATION INTERFACES MULTIFUNCTIONAL ISOLATION DISPLAY No 4510V100 UK From serial no 221207001 ...

Страница 2: ...nication interfaces that can access your PR installed base of products All the interfaces are detachable have a built in display for readout of process values and diagnostics and can be configured via push buttons Product specific functionality includes communication via Modbus and Bluetooth and remote access using our PR Process Supervisor PPS application available for iOS and Android Our display...

Страница 3: ...4500 communication interface 4 Applications 5 Technical characteristics 5 Mounting installation programming 5 Order 6 Electrical specifications 6 Display layout 7 Operating the function keys display 8 4510 settings routing diagram 10 ATEX Installation Drawing 11 IECEx Installation Drawing 13 FM Installation Drawing 15 Document history 17 ...

Страница 4: ... device If the equipment is used in a manner not specified by the manufacturer the protection provided by the equipment may be impaired Repair of the device must be done by PR electronics A S only Symbol identification Triangle with an exclamation mark Read the manual before installation and commissioning of the device in order to avoid incidents that could lead to personal injury or mechanical da...

Страница 5: ...han 60ºC The device must therefore be installed so that it is only accessible to service personnel or users that are aware of the reason for restricted access and the required safety measures at an ambient temperature of 55ºC to 60ºC Mounting Only qualified technicians who are familiar with the technical terms warnings and instructions in this installation guide and who are able to follow these sh...

Страница 6: ...figmate or all system 4000 9000 fronts for programming and signal monitoring Mounting 1 Insert the tabs of the PR 4500 into the holes at the top of the device 2 Hinge the PR 4500 down until it snaps into place Demounting 3 Push the release button on the bottom of the PR 4500 and hinge the the PR 4500 out and up 4 With the PR 4500 hinged up remove from the holes at the top of the device ...

Страница 7: ...e saved and downloaded to subsequent transmitters Technical characteristics Easy to read dot matrix LCD display Backup memory for loading and saving of device configuration Programming access can be blocked by assigning a password The password is saved in the device in order to ensure a high degree of protection against unauthorized modifications to the configuration Mounting installation programm...

Страница 8: ...1 mm Weight approx 20 g Common specifications Supply voltage 6 5 20 V supplied from host 4000 9000 device Max required power 0 15 W Observed authority requirements EMC 2014 30 EU UK SI 2016 1091 ATEX 2014 34 EU UK SI 2016 1107 RoHS 2011 65 EU UK SI 2012 3032 Approvals c UL us UL 61010 1 E314307 Pending Ex ATEX DEKRA 13ATEX0098 X IECEx DEK 13 0026 X FM US FM22US0014X Pending FM CA FM22CA0009X Pendi...

Страница 9: ... 4000 Line 1 shows the scaled process value Line 2 shows the selected engineering unit Line 3 shows analog output value or TAG no Line 4 shows status for relay communication and e g signal trending PR 9000 Line 1 shows status for input channel s Line 2 and 3 show analog output value digital output status analog input value TAG no where appliable or alternating values Line 4 shows status for relay ...

Страница 10: ... For device specific programming menus please refer to the user manual for each device e g PR 4116 4510 display icons explained PR 3000 4000 Relay status Relay energized Icon with 1 or 2 blinking indicates delayed relay action programmable on off delay Arrow up down indicates process value is trending higher lower Circular indicator confirms display to host communication PR 9000 Relay status Relay...

Страница 11: ...functions which can be reached by answering Yes to the menu point ADV SET see 4510 settings routing diagram on page 10 Display orientation The menu item ORIEN allows the user to rotate the display 180 degrees for correct operation with upside down mounting of the device ...

Страница 12: ...m Memory operations MEM MEM 8 Rotate device upside down SETUP OK 3 DISP v MEM DISP CAL CAL SIM PASS SIM LANG ORIEN PASS LANG ORIEN NO ROT DEV OK Monitor 8 v YES NO PR electronics A S 4510_Local_Menu xlsx 10 4510V100 UK 4510 settings routing diagram Returns to Monitor from any menu after 1 minute with no keypress The gray shaded menus texts are only shown for guidance and are not part of the PR 451...

Страница 13: ...20 C Ta 60 C ATEX UKEX Installation Instructions For safe installation of the 4500 series of products the following must be observed Unclassified Area Hazardous Area II 3G Ex IIC PR 4000 9000 PR 4000 9000 PR 4000 9000 4511 4511 4511 IP 54 T Gateway PLC DCS HMI PC Modbus RTU Unclassified Area Hazardous Area II 3G Ex IIC PR 4000 9000 PR 4000 9000 PR 4000 9000 4510 4512 IP 54 4510 4512 4510 4512 ...

Страница 14: ...unting of PR 4500 communications interface 1 Insert the tabs of the PR 4500 into the slots at the top of the device 2 Hinge the PR 4500 down until it snaps into place Demounting of the PR 4500 communication interfaces 3 Push the release button on the bottom of the PR 4500 and hinge the PR 4500 out and up 4 With the PR 4500 hinged up remove from the slots at the top of the device Specific Condition...

Страница 15: ...IECEx Installation Instructions For safe installation of the 4500 series of products the following must be observed Unclassified Area Hazardous Area PR 4000 9000 PR 4000 9000 PR 4000 9000 4511 4511 4511 IP 54 T Gateway PLC DCS HMI PC Modbus RTU Unclassified Area Hazardous Area PR 4000 9000 PR 4000 9000 PR 4000 9000 4510 4512 IP 54 4510 4512 4510 4512 4510V100 UK 13 ...

Страница 16: ...00 communications interface 1 Insert the tabs of the PR 4500 into the slots at the top of the device 2 Hinge the PR 4500 down until it snaps into place Demounting of the PR 4500 communication interfaces 3 Push the release button on the bottom of the PR 4500 and hinge the PR 4500 out and up 4 With the PR 4500 hinged up remove from the slots at the top of the device Specific Conditions of Use The eq...

Страница 17: ...r safe installation of the 4500 series of products the following must be observed Unclassified Area Hazardous Area CL I Div2 GP A B C D CL I Zone 2 AEx Ex ec IIC T5 Gc PR 4000 9000 PR 4000 9000 PR 4000 9000 4511 4511 4511 IP 54 T Gateway PLC DCS HMI PC Modbus RTU Unclassified Area Hazardous Area CL I Div2 GP A B C D CL I Zone 2 AEx Ex ec IIC T5 Gc PR 4000 9000 PR 4000 9000 PR 4000 9000 4510 4512 I...

Страница 18: ...ce 2 Hinge the PR 4500 down until it snaps into place Demounting of the PR 4500 communication interfaces 3 Push the release button on the bottom of the PR 4500 and hinge the PR 4500 out and up 4 With the PR 4500 hinged up remove from the slots at the top of the device Specific Conditions of Use Class 1 Division 2 In Class I Division 2 installations the subject equipment shall be mounted within a t...

Страница 19: ...4510V100 UK 17 Document history The following list provides notes concerning revisions of this document Rev ID Date Notes 100 2215 Initial release of the product ...

Страница 20: ...entation We are headquartered in Denmark and have offices and authorized partners the world over We are a local business with a global reach This means that we are always nearby and know your local markets well We are committed to your satisfaction and provide PERFORMANCE MADE SMARTER all around the world For more information on our warranty program or to meet with a sales representative in your r...

Страница 21: ...andards for products communicating monitoring and connecting our customers process measurement points to their process control systems Our innovative patented technologies are derived from our extensive R D facilities and from having a great understanding of our customers needs and processes We are guided by principles of simplicity focus courage and excellence enabling some of the world s greates...

Отзывы: