background image

4

5

TECHNICAL FEATURES

*M

aximum heigh

t is calcula

ted fr

om the v

alue obtained in the pr

oduc

t descr

iption (Heigh

t in met

ers) applied in the equa

tion abo

ve

.

BV HOME CUSTOM

BV HOME

TYPE OF GATE OPERATOR

OVERHEAD

OVERHEAD

OVERHEAD

MOTOR

Single-Phase

Single-Phase

Single-Phase

POWER SUPPLY

220 V / 127 V

220 V

127 V

RATED FREQUENCY

60 Hz

60 Hz

60 Hz

RATED POWER

430 W / 290 W

315 W

325 W

MOTOR RPM

1740 RPM

1740 RPM

1740 RPM

RATED CURRENT

1.6 A / 2.3 A

1.4 A

2.9 A

REDUCTION RATIO

1:26

1:26

1:26

LINEAR SPEED

4.15 m/min

4.15 m/min

4.15 m/min

CYCLES/HOUR

20

30

30

PROTECTION RATING

IPX4

IPX4

IPX4

C-CHANEL (MATERIAL)

Aluminum

Aluminum

Aluminum

OPERATING

TEMPERATURE

-5°C/+50°C

(41°F/122°F)

-5°C/+50°C 

(41°F/122°F)

-5°C/+50°C 

(41°F/122°F)

INSULATION SYSTEM

Class B, 130°C (266°F)

Class B, 130°C (266°F)

Class B, 130°C (266°F)

LIMIT SWITCH SYSTEM

Analog/Digital

Analog/Digital

Analog/Digital

MAX LEAF WEIGHT

200 Kg (~441lb.)

300 Kg (~662lb.)

300 Kg (~662lb.)

MAX LEAF SIZE

*HEIGHT = (Height in

meter - 15cm) x 2

LENGTH = 4m

*HEIGHT = (Height in

meter - 15cm) x 2

LENGTH = 4m

*HEIGHT = (Height in

meter - 15cm) x 2

LENGTH = 4m

BV HOME CUSTOM 

SP

BV HOME SP

BV HOME CUSTOM 

JETFLEX

BV HOME JETFLEX

TYPE OF GATE OPERA-

TOR

OVERHEAD

OVERHEAD

OVERHEAD

OVERHEAD

MOTOR

Single-Phase

Single-Phase

Jet Flex

Jet Flex

POWER SUPPLY

127 V / 220 V

220 V / 127 V

220 V / 127 V

220 V / 127 V

RATED FREQUENCY

60 Hz

60 Hz

60 Hz

60 Hz

RATED POWER

280 W / 210 W

435 W / 320 W

380 W

345 W

MOTOR RPM

1740 RPM

1740 RPM

5800 RPM

4365 RPM

RATED CURRENT

2.5 A / 1.5 A

2 A / 2.8 A

2.8 A / 3.7 A

1.6 A / 3.7 A

REDUCTION RATIO

2:30

2:30

2:30

2:30

LINEAR SPEED

7.2 m/min

7.2 m/min

23.9 m/min

18 m/min

CYCLES/HOUR

20

30

30

40

PROTECTION RATING

IPX 4

IPX 4

IPX 4

IPX 4

C-CHANEL (MATERIAL)

Aluminum /Steel

Aluminum

Aluminum

Aluminum

OPERATING

TEMPERATURE

-5°C/+50°C

(41°F/122°F)

-5°C/+50°C

(41°F/122°F)

-5°C/+50°C

(41°F/122°F)

-5°C/+50°C

(41°F/122°F)

INSULATION SYSTEM

Class B, 130°C (266°F)

Class B, 130°C (266°F)

Class B, 130°C (266°F)

Class B, 130°C (266°F)

LIMIT SWITCH SYSTEM

Analog

Hybrid

Hybrid

Hybrid

MAX LEAF WEIGHT

200 Kg (~441lb.)

250Kg (~552lb.)

250Kg (~552lb.)

250Kg (~552lb.)

MAX LEAF SIZE

*HEIGHT = (Height

in meter - 15cm) x 2

LENGTH = 4m

*HEIGHT = (Height

in meter - 15cm) x 2

LENGTH = 4m

*HEIGHT = (Height

in meter - 15cm) x 2

LENGTH = 4m

*HEIGHT = (Height

in meter - 15cm) x 2

LENGTH = 4m

BASIC TOOLS NEEDED FOR 
INSTALLATION 

Tools needed:

ELECTRICAL CONNECTIONS

For the electrical set-up, the power grid must have the following features:

- 127 V / 220 V Power Supply

- 5A Circuit Breakers in the Electrical Panel

- 3/4” diameter conduits between the electrical panel and the disconnection device

- 3/4” diameter conduits between the disconnection device and the outlet

- 1/2” diameter conduits for (optional) external pushbuttons

- 1/2” diameter conduits for (optional) photocells.

LINEMAN’S 

PLIERS

HACKSAW

HEX NUT DRIVER

SCREWDRIVER

OPEN-END WRENCH

STEPLADDER

WELDING MACHINE

HAMMER

SPIRIT LEVEL

TAPE MEASURE

TRY SQUARE

ELECTRIC DRILL

PENCIL

ELECTRIC SANDER 

/ HAND GRINDER

Содержание BV HOME Series

Страница 1: ...nual P30566 08 2022 Rev 1 All images in this manual are for illustrative purposes only Made by Motoppar Ind stria e Com rcio de Automatizadores Ltda Av Dr Labieno da Costa Machado 3526 Distrito Indust...

Страница 2: ...complies with the technical data appearing on the gate s label Do not connect the operator to the source ofpoweruntiltheinstallation maintenance or servicing is over Proceed the wiring of the control...

Страница 3: ...RATED POWER 280 W 210 W 435 W 320 W 380 W 345 W MOTOR RPM 1740 RPM 1740 RPM 5800 RPM 4365 RPM RATED CURRENT 2 5 A 1 5 A 2 A 2 8 A 2 8 A 3 7 A 1 6 A 3 7 A REDUCTION RATIO 2 30 2 30 2 30 2 30 LINEAR SP...

Страница 4: ...nual release must be installed at a height of less than 1 8m 6 ft If there are pushbuttons optional fixed control install them at a height of at least 1 5m 5 ft from the floor and close to the door fa...

Страница 5: ...Remove the top cover from the rail and install the mounting brackets opposite the lead nut Step 3 Insert the closing stopper with the rubber part facing the lead nut Step 4 Insert the opening stopper...

Страница 6: ...distance from the middle of the traction lever s hinge and the niddle of the lead nut pin Step 10 With the gate still closed adjust the closing stopper so that its rubber part cushions the lead nut wh...

Страница 7: ...No power supply B Open Blown fuse C Gate jammed D Defective limit switch A Ensure that the power cable is correctly inserted in the power outlet B Substitute the fuse for another one with the same spe...

Отзывы: