![powersoft Ottocanali HGT Series Скачать руководство пользователя страница 8](http://html1.mh-extra.com/html/powersoft/ottocanali-hgt-series/ottocanali-hgt-series_service-manual_1591310008.webp)
8
OTTOCANALI HGT | SERVICE MANUAL
3. Internal LED Statuses
8CHHGT/STD/ANALOG LED Status
8CHHGT/STD/CNTRL LED Status
–12V green
+12V green
+5V green
Hi-Temp yellow
Over Temperature: Yellow
High Temperature: Green
Average Fans Speed: Green
Highest Fans Speed: Green
+5V: Green
+12V: Green
-12V: Green
In order to check the internal status LEDs, connect the
amplifier to the mains, and switch it on.
Refer to the following table for the LED configurations.
In order to check the internal status LEDs, connect the
amplifier to the mains, and switch it on.
All LEDs should be off during the power up procedure.
Refer to the following table for the LED configurations.
LED
COLOR STATUS ACTION
NORMAL
CONDITION
AUX LEDs
-12V
GREEN
ON
+12V
GREEN
ON
+5V
GREEN
ON
HITEMP YELLOW
OFF
FAUL
TY
CONDITION
AUX LEDs
-12V
GREEN
OFF
Replace the 8CHHGT/
STD/ANALOG board
+12V
GREEN
OFF
+5V
GREEN
OFF
HITEMP YELLOW
OFF
FAUL
TY
CONDITION
AUX LEDs
-12V
GREEN
ON
Check the Modules
+12V
GREEN
ON
+5V
GREEN
OFF
HITEMP YELLOW
OFF
LED
COLOR STATUS ACTION
NORMAL CONDITION
F.MAX
GREEN
OFF
F.MED
GREEN
OFF
H.T.
GREEN
OFF
O.T.
YELLOW
OFF
AUX LEDs
+5V
GREEN
ON
-12V
GREEN
ON
+12V
GREEN
ON
FAUL
TY CONDITION
F.MAX
GREEN
OFF
Replace the 8CHHGT/
STD/CNTRL Board
F.MED
GREEN
OFF
H.T.
GREEN
OFF
O.T.
YELLOW
OFF
AUX LEDs
+5V
GREEN
OFF
-12V
GREEN
OFF
+12V
GREEN
OFF
FAUL
TY CONDITION
F.MAX
GREEN
OFF
Check the Modules
F.MED
GREEN
OFF
H.T.
GREEN
OFF
O.T.
YELLOW
OFF
AUX LEDs
+5V
GREEN
OFF
-12V
GREEN
ON
+12V
GREEN
ON
FAUL
TY CONDITION
F.MAX
GREEN
ON
Check the Modules
F.MED
GREEN
ON
H.T.
GREEN
ON
O.T.
YELLOW
ON
AUX LEDs
+5V
GREEN
ON
-12V
GREEN
ON
+12V
GREEN
ON