- 29 -
4. led display (operatinG modes)
The display is on the rear of the casing blow the rivet mandrel container. The
following signals can be output during operation:
LED illuminates brief-
ly, red and green
Functional test after
installing the battery
and pressing the
start button
LED blinks green
Pressure switch must
be released prior to
every placement
process
Release the pressure
switch; a new rivet-
ing process can be
started
LED blinks orange
Battery almost
empty,
work can continue
Replace or charge
battery
LED illuminates red
Fault: The riveting
device is defective; it
no longer functions
Contact the manu-
facturer
LED illuminates
orange
Battery empty,
work cannot con-
tinue
Replace or charge
battery
LED rapidly blinks red Fault: Overcurrent
due to an excessive
mandrel breaking
load or the device
has overheated
(55 °C)
Incorrect blind rivet
used or tension unit
is dirty or damaged.
Maintain tension unit
and let the device
cool down.
LED display
Description of
the status
Action
When you connect the battery for the first time, it must be at least 40% full or
the display will indicate it is empty.
Im Martelacker 12 – D-79588 Efringen-Kirchen – Telefon 0 76 28 - 91 11- 0 – Telefax 0 76 28 - 91 11-90
E-Mail: [email protected] – Internet: www.hs-technik.com
LED illuminates green Rivet mandrel con-
tainer not installed
or not installed cor-
rectly or
pressure switch not
pressed
Correctly install the
rivet mandrel and
press the pressure
switch