12 NOISE 

Noise emission values measured according to relevant standard. (K=3) 

Acoustic power level LwA 

71 dB(A) 

13 PROBLEM-SOLVING 

Common Malfunction  

Cause 

Solution 

The opeating switch is 
used but the motor 
does not turn 

1. It is not plugged into the power 
supply. 
2. The wires are broken or 
ripped. 
3. Switch Malfunction 
4. The capacitor is burned 
through. 
5. End-switch has not been reset 
or a micro switch error 
6. The thermal switch has 
suffered a wire break. 

1. Connect the item to the 
power supply. 
2. Check the wires and plug it in 
again to the outlet. 
3. Repair switch or change it 
4. Change your capacitor 
5. Check the end-switch and 
replace the limit switch. 
6. Wait until the item cools 
down, or replace the thermal 
switch. 

The operation switch 
switch has been 
activated. The motor is 
very loud, can however 
not pick-up the load. 

1. The voltage offered is too 
small. 
2. The capacitor has become 
damaged. 
3. The brake is not completely 
open. 

1. Adjust the work, depending 
on the power supply 
2. Change power supply. 
3. Allow the machine to be 
repaired from a qualified repair 
service 

After a power loss the 
brakes do not hold or 
the machine slips down 

 

The air between the brakes is 
too large 

 

The brake spring is ripped. 

 

The brake disk is locked 

 

The brake disk is at the start 
already dirty. 

 

Allow the machine to be 
repaired from a qualified 
repair service. 

The noise of the 
machine becomes 
louder 

1. Badly oiled 
2. After a long use, the cogwheel 
and bearings are damaged. 
3. Badly installed or dent 

1. Oil/Grease machine officially. 
2. Change the cogwheel or 
bearings. 
3. Check installed parts or let 
a qualified person check this 

The cable hoist has too 
much voltage. 

1. Earthed error or is not possible 
2. The internal connectors are 
touching the housing 

1. Checked earthed wires and 
properly connect them. 
2. Check all internal 
connections 

End-switch is not 
functioning. 

1. The end-switch is defect 
2. End-switch is blocked 

1. Switch off or change 
2. Check, repair, and change 
End switch 

 

 

Содержание POWX900

Страница 1: ...y 3 5 3 Personal safety 3 5 4 Power tool use and care 4 5 5 Service 4 6 EXTRA SAFTY INFORMATION 4 7 BEFORE EVERY USE 5 8 INSTALLATION 6 9 OPERATION 6 9 1 Intermittent rating 7 9 2 Overload Only for PO...

Страница 2: ...switch Up Down 17 Power cord 3 PACKAGE CONTENT LIST Remove all packaging materials Remove remaining packing and package inserts if included Check that the package contents are complete Check the appl...

Страница 3: ...he power tool Keep the cord away from heat oil sharp edges or moving parts Damaged or entangled cords increase the risk of an electric shock When operating a power tool outdoors use an extension cable...

Страница 4: ...ies and cutting tools etc in accordance with these instructions and in the manner intended for the particular type of power tool taking into account the working conditions and the work which needs to...

Страница 5: ...in operation do not carry out any repairs or inspections It is prohibited to change any part of the pulley or to disassemble it Depending on the frequency of use after 20 hours of total operation or...

Страница 6: ...casing 3 when using the load hook with pulley 13 The electric pulley will be attached at the top Attach the pulley with bearer frame on the crossbar The girder is then attached to the support columns...

Страница 7: ...r water damage The cable hoist uses a single phase energy power supply The nominal voltage is 230V 20 the nominal frequency is 50Hz 1 The motor must be safely grounded In the circuitry of the power su...

Страница 8: ...eel cable 7 for damages as well as the functionality of the limit bracket Wind cable hoist until the stopper 10 activates the limit bracket of the micro switch If the steel cable 7 is damaged split or...

Страница 9: ...oo small 2 The capacitor has become damaged 3 The brake is not completely open 1 Adjust the work depending on the power supply 2 Change power supply 3 Allow the machine to be repaired from a qualified...

Страница 10: ...netration intentional damage on purpose or by gross carelessness inappropriate usage use for purposes for which the device is not suitable incompetent usage e g not following the instructions given in...

Страница 11: ...ards Any unauthorized modification of the apparatus voids this declaration European Directives including if applicable their amendments up to the date of signature 2014 30 EU 2006 42 EC 2011 65 EU Eur...

Отзывы: