
POWX1183
EN
Copyright © 2015 VARO NV
P a g e
|
7
www.varo.com
10 TECHNICAL DATA
Rated Voltage
220-240 V
Rated Frequency
50 Hz
Rated Power
1050 W
Rotation speed
750 min
-1
Protection class
II
Impact rate
4300 min
-1
Cable length
3 m + VDE plug
11 NOISE
Noise emission values measured according to relevant standard. (K=3)
Acoustic pressure level LpA
98 dB(A)
Acoustic power level LwA
105 dB(A)
ATTENTION!
Wear
hearing
protection
when
sound
pressure
is
over 85 dB(A).
aw (Vibration)
18,4 m/s²
K = 1,5 m/s²
12 SERVICE DEPARTMENT
Damaged switches must be replaced by our after-sales service department.
If the connecting cable (or mains plug) is damaged, it must be replaced by a particular
connecting cable which is available from our service department. Replacement of the
connecting cable must only be carried out by our service department (see last page) or by
a qualified person (qualified electrician).
13 STORAGE
Thoroughly clean the whole machine and its accessories.
Store it out of the reach of children, in a stable and secure position, in a cool and dry
place, avoid too high and too low temperatures.
Protect it from exposure to direct sunlight. Keep it in the dark, if possible.
Don’t keep it in plastic bags to avoid humidity build-up.