Owner’s Manual for Portable Generator

3

Electrical Hazards

• The National Electric Code (NEC) requires

the frame and external electrically conduc-

tive parts of the generator be properly con-

nected to an approved earth ground. Local

electrical codes may also require proper

grounding of the generator. Consult with a

local electrician for grounding requirements

in the area.

• Use a ground fault circuit interrupter in any

damp or highly conductive area (such as

metal decking or steel work).

Fire Hazards

• Wipe up any fuel or oil spills immediately.

Verify that no combustible materials are left

on or near the generator. Keep the area

surrounding the generator clean and free

from debris and keep a clearance of five (5)

feet on all sides to allow for proper ventila-

tion of the generator.

• Do not operate the generator if connected

electrical devices overheat, if electrical out-

put is lost, if engine or generator sparks or if

flames or smoke are observed while unit is

running.

• Keep a fire extinguisher near the generator

at all times.

Standards Index

1. National Fire Protection Association

(NFPA) 70: The NATIONAL ELECTRIC

CODE (NEC) available from www.nfpa.org

2. National Fire Protection Association

(NFPA) 5000: BUILDING CONSTRUC-

TION AND SAFETY CODE available from

www.nfpa.org

3. International Building Code available from

www.iccsafe.org

4. Agricultural Wiring Handbook available

from www.rerc.org, Rural Electricity

Resource Council P.O. Box 309 Wilming-

ton, OH 45177-0309

5. ASAE EP-364.2 Installation and Mainte-

nance of Farm Standby Electric Power

available from www.asabe.org, American

Society of Agricultural & Biological Engi-

neers 2950 Niles Road, St. Joseph, MI

49085

This list is not all inclusive. Check with the

Authority Having Jurisdiction (AHJ) for any

local codes or standards which may be appli-

cable to your jurisdiction. 

(000144)

DANGER

Electrocution. Contact with bare wires, 
terminals, and connections while generator 
is running will result in death or serious injury.

(000104)

DANGER

Electrocution. Water contact with a power source, 
if not avoided, will result in death or serious injury.

(000145)

DANGER

Electrocution. In the event of electrical accident,  
immediately shut power OFF. Use non-conductive  
implements to free victim from live conductor. Apply  
first aid and get medical help. Failure to do so will  
result in death or serious injury

.

(000130)

WARNING

Accidental Start-up. Disconnect the negative battery 
cable, then the positive battery cable when working 
on unit. Failure to do so could result in death 
or serious injury.

(000105)

DANGER

Explosion and Fire. Fuel and vapors are extremely 
flammable and explosive. Add fuel in a well 
ventilated area. Keep fire and spark away. Failure to
do so will result in death or serious injury. 

(000166)

DANGER

Do not overfill fuel tank. Fill to 1/2 in. of top of tank to
allow for fuel expansion. Overfilling may cause fuel to
spill onto engine causing fire or explosion, which will
result in death or serious injury.

(000142)

Do not insert any object through the air cooling slots.
Generator can start at any time and could result in 
death, serious injury, and unit damage.

WARNING

WARNING

Fire risk. Fuel and vapors are extremely 
flammable. Do not operate indoors. Doing so 
could result in death, serious injury, or 
property or equipment damage.

(000281)

WARNING

Explosion and fire risk. Do not smoke near unit. 
Keep fire and spark away. Failure to do so could 
result in death, serious injury, or property or 
equipment damage.

(000282)

WARNING

Explosion and fire risk. Do not smoke while 
refueling unit. Failure to do so could result in 
death, serious injury, or property or equipment 
damage.

(000284)

Содержание CX6500E

Страница 1: ...t intended to be used in a critical life support application Failure to adhere to this warning could result in death or serious injury MODEL ________________________ SERIAL ________________________ DA...

Страница 2: ...1 Transporting Tipping of the Unit 11 Starting Pull Start Engines 12 Starting Electric Start Engines 12 Generator Shut Down 12 Low Oil Level Shutdown System 12 Section 4 Maintenance and Troubleshootin...

Страница 3: ...ughout this publication and on tags and decals affixed to the generator DANGER WARNING CAUTION and NOTE blocks are used to alert personnel to special instructions about a particular operation that may...

Страница 4: ...hair and appendages away from moving parts Failure to do so could result in death or serious injury 000108 WARNING Hot Surfaces When operting machine do not touch hot surfaces Keep machine away from c...

Страница 5: ...the Authority Having Jurisdiction AHJ for any local codes or standards which may be appli cable to your jurisdiction 000144 DANGER Electrocution Contact with bare wires terminals and connections while...

Страница 6: ...14 17 1 120 Volt AC 20 Amp GFCI Duplex Receptacle 2 120 Volt AC 30 Amp Locking Receptacle NEMA L5 30 CX8000E only 3 120 240 Volt AC 30 Amp Locking Receptacle NEMA L14 30R 4 Circuit Breakers AC 5 Off O...

Страница 7: ...cifications 6 5 kW 8 0 kW Generator Specifications Rated Power 6500 Watt 8000 Watt Surge Power 8125 Watt 10000 Watt Rated AC Voltage 6 5 and 8 0 kW 120 240 Rated AC Load 6 5 kW 8 0 kW 54 2 27 1 Amps 6...

Страница 8: ...Hz single phase loads requiring up to 6480 watts 6 4 kW of power at 27 Amps The outlet is protected by two 27 Amp 2 pole connected toggle circuit breakers CX8000E Use this receptacle to operate 120 V...

Страница 9: ...through axle 4 Bend tabs of cotter pins outward to lock into place Install frame foot assembly as follows 1 Slide M8 flat washer 8 rubber foot 5 foot spacer 4 onto M8 x 80 bolt 10 2 Align through hole...

Страница 10: ...the black cable to the negative battery terminal with the bolt and nut sup plied Slide rubber boot over the negative battery terminal and connection hard ware 5 Make sure all connections are secure N...

Страница 11: ...area around fuel cap and remove cap slowly 4 Slowly add recommended fuel Do not fill above red fuel indicator A See Figure 2 10 5 Install fuel cap Figure 2 10 Add Recommended Fuel NOTE Allow spilled...

Страница 12: ...f the generator is used at a construction site there may be additional regulations which must be observed Connecting the Generator to a Building Electrical System When connecting directly to a buildin...

Страница 13: ...e for wattage requirements Table 3 Wattage Reference Guide Transporting Tipping of the Unit Do not store or transport the unit at an angle greater than 15 degrees Device Running Watts Air Conditioner...

Страница 14: ...in the START position When engine starts release the switch to the ON position 6 When engine starts move choke knob to 1 2 choke position until engine runs smoothly then fully to ON position If engin...

Страница 15: ...ed NOTE DO NOT use a garden hose to clean generator Water can enter engine fuel system and cause problems If water enters generator through cooling air slots some water will be retained in voids and c...

Страница 16: ...n area around oil fill and oil drain plug 4 Remove oil fill cap 5 Remove oil drain plug and drain oil com pletely into a suitable container 6 Install oil drain plug and tighten securely 7 Slowly pour...

Страница 17: ...or oper ate the engine on any forest covered brush covered or grass covered land unless the exhaust system is equipped with a spark arrester as defined in Section 4442 main tained in effective working...

Страница 18: ...If fuel stabilizer is added to fuel system pre pare and run engine for long term storage Run engine for 10 15 minutes to circulate sta bilizer throughout fuel system Adequately prepared fuel can be s...

Страница 19: ...5 Stale fuel 6 Dirty fuel filter 7 Spark plug wire not connected to spark plug 8 Bad spark plug 9 Water in fuel 10 Overchoking 11 Low oil level 12 Excessive rich fuel mixture 13 Intake valve stuck ope...

Страница 20: ...18 No battery charge DC output 1 Battery posts corroded 2 Bad battery cable 3 Defective battery 4 Bad receptacle 1 Clean battery posts 2 Replace cable 3 Check battery condition Replace if defective 4...

Страница 21: ...19 Owner s Manual for Portable Generator Notes...