Power over LAN™ Midspans 

PD-6006, PD-6012 & PD-6024 

6/12/24-Port Models 

IEEE 802.3af-compliant

 

 
 

User Guide 

 

 

Data and Power on a Single Line

Содержание PD-6006

Страница 1: ...Power over LAN Midspans PD 6006 PD 6012 PD 6024 6 12 24 Port Models IEEE 802 3af compliant User Guide Data and Power on a Single Line ...

Страница 2: ... use only 2003 PowerDsine Ltd All rights reserved This document is subject to change without notice Original publication 19 March 2003 Date Printed Jun 18 2003 Acknowledgements Power over LAN is a trademark of PowerDsine Ltd All other products or trademarks are property of their respective owners The product s described by this manual is are a licensed product of PowerDsine Notice The information ...

Страница 3: ...2 1 Data Input Ports 8 2 2 2 Data Power Output Ports 8 2 3 Indicators 8 2 3 1 Primary Power Indicators 8 2 3 2 Port Indications 9 2 4 Connectors 10 3 INSTALLING THE POWER OVER LAN MIDSPAN 11 3 1 Background Information 11 3 2 Rack Mounting Brackets 11 3 3 Connecting Ethernet Cables 12 3 4 Connecting Power Cables 12 3 5 Powering up 12 3 6 Troubleshooting 12 3 6 1 Preliminary Steps 12 3 6 2 Troublesh...

Страница 4: ...ounting brackets Self adhesive rubber feet User Guide Power cord Before proceeding record the unit s serial number below for future reference The serial number can be found on the information label at the rear of the Power over LAN Midspan Serial Number Electrical Compatibility Approvals The PD 60xx ACDC complies with the following standards FCC Part 15 Class B with FTP cabling Class A with UTP ca...

Страница 5: ...cuit breaker no larger than 15 A for 120 VAC U S 10 A for 230 VAC international is used Do not work on the system connect or disconnect cables during periods of lightning activity A voltage mismatch can cause equipment damage and may pose a fire hazard If the voltage indicated on the label is different from the power outlet voltage do not connect the Power over LAN Midspan to this outlet For shelf...

Страница 6: ...n and not to the wall plug must have a configuration for mating with an EN60320 IEC320 appliance inlet The power socket outlet must be near the Midspan and be easily accessible You can only remove power from the unit by disconnecting the power cord from the outlet This unit operates under SELV Safety Extra Low Voltage conditions according to EN60950 IEC 950 The conditions are only maintained if th...

Страница 7: ...rs Universal range power input 100 240 VAC 50 60 Hz and or 46 to 57 VDC Power management SNMP management optional Independent overload and short circuit protection per channel Port status indications Standard 19 inch rack mountable 2 1 Power Management When establishing a network the total power required by PDs may exceed the total power available from the Midspan The built in Power Management fea...

Страница 8: ...d 7 8 Figure 2 1 Power over LAN Midspan Front View PD 6024 2 3 Indicators A set of indicators provide the status of the Power over LAN Midspan and its ports Refer to Table 2 1 and Table 2 2 for status information during operation 2 3 1 Primary Power Indicators Depending on the configuration ordered there may be two LEDs on the front panel marked by AC and DC to provide the Power over LAN Midspan p...

Страница 9: ... way Ethernet devices not PoL enabled will not be affected by this connection Table 2 1 Power Status Indications Indicator Color Main Power Status Remarks Off Internal power supply unit is unplugged or faulty Internal power supply voltage is too low All ports are disconnected Green Indicates AC power input active Internal power supply voltage is within tolerance AC Green blinking Internal power su...

Страница 10: ...e blinking Total aggregated power exceeds pre defined power budget Power to the port is disconnected No DC voltage is present on the spare pairs 2 4 Connectors The front panel of the Midspan includes a Console port DB 9 connector The user may connect a terminal and perform software loading via this connector using a standard null modem cable The console port is set to 19 200 baud 8 data bits no pa...

Страница 11: ...ns 7 8 and pins 4 5 of the Category 5 cabling without degrading the quality of data communications Most installations require the Midspan to be rack mounted as described hereafter Figure 3 1 Typical Installation 3 2 Rack Mounting Brackets The Midspan comes with 19 in mounting brackets and screws To install the Midspan into a 19 in rack first remove the self adhesive rubber feet from the bottom sur...

Страница 12: ...5 Powering up The Power over LAN Midspan has no on off switch To apply or remove power to the Midspan insert or remove the power cable from the receptacle AC and or DC on the rear panel of the unit With power applied the Midspan powers up and the internal fan operates then the device runs through its power on self test POST which takes less than 10 seconds During the POST all ports are disabled an...

Страница 13: ...ort indicator is not lit and the corresponding PD does not operate 1 The Midspan did not detect a PD and therefore the port is not enabled 2 Verify that the PD is designed for Power over LAN operation 3 Verify that you are using a standard Category 5 5e 6 straight wired cable with four pairs 4 If an external power splitter is in use replace it with a known good splitter 5 Verify that the PD is con...

Страница 14: ...Specifications Physical Specifications Dimensions 44 x 433 x 302 mm h x w x l 1 75 x 17 x 11 9 inch Weight 4 kg 8 8 lb Environmental Specifications Temperature Operating 0 to 40 C 32 to 104 F Storage 20 to 70 C 4 to 158 F Humidity 10 to 90 non condensing Electrical Specifications Parameter PD 6006 PD 6012 PD 6024 AC Input Voltage 90 to 264 VAC at 47 63 Hz DC Input Voltage 46 to 57 VDC Input Curren...

Страница 15: ...figuration of PowerDsine products via their SNMP agents PowerDsine PowerView allows for monitoring and controlling at Network and Element levels as shown in Figure 4 1 Figure 4 1 Management Deployment PowerDsine PowerView provides a number of unique features for PoL Midspan management Web based application for remote management of Power over LAN devices Web management capabilities for network elem...

Страница 16: ...Part Number 06 6800 056 Release 1 0 Covered under US Patent 6 473 608 Visit our web site at www powerdsine com For technical support call 972 9 7755123 In the USA 631 756 4680 or 1 877 4 802 3AF ...