PowerBox OFI1200A Series Скачать руководство пользователя страница 3

 
POWERBOX 

Industrial Line 

OFI1200A Series 
1200W Single output 
AC/DC Baseplate power supply 

 

www.prbx.com 

 

 

 

 

 

 

2022.07.21 

 

 

 

 

 

 

 

Specifications are subject to change without notice. 

 

 

 
 
 
 
 
 
 
 
 
 
 
 

Fig. 2.3 Derating curve of point A (baseplate temperature)  

 
Remarks: 
Operation in the hatched area may cause significant level of ripple and 
ripple noise. 
 
<Temperature measurement with cover option> 
To measure a temperature of internal components in units with option 
-N (with cover), it is necessary to remove the cover to apply 
thermocouples on measuring points. 
 
To remove the cover, remove cables from input terminal and remove 4 
screws on each corner. 
There are an isolation sheet and gap pads on the input filter. When the 
cover is re-installed, make sure that the isolation sheet and gad pads 
are properly located. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Fig. 2.4 Screws to be removed for temperature measurement 

 

3.  Wiring 

3.1 Wiring input connector 

(1) Built-in fuse 
The two 16 ampere AC fuses are built-in on AC(L) in parallel. 
 
(2) Wire 
Connection capability of the input connector. 

Input connector type 

 

: MKDS 5/ 3-9,5 (1714984) 

 

 

  

(Phoenix Contact) 

Connector cross section solid 

: 0.2 mm

2

 

 6 mm

Connector cross section flexible

 

: 0.2 mm

2

 

 4 mm

2

 

Conductor cross section (AWG) 

: AWG 24 

 10 

Conductor cross section (flexible, with ferrule) 
 

 

 

: 0.25 mm

2

 

 4 mm

2

 

Stripping length 

 

 

: 8mm 

Torque 

 

 

: 0.5 

 0.6 Nm

 

An input current is dependent on input voltage and output current. 
Choose the appropriate thickness for the input wire. 
 
Influence against noise is improved if the input wires are twisted. In 
addition, make sure that input and output wires are separated.  
 
(3) FG terminal 
The FG terminal on input connector shall be Functional Ground. 
Make sure that the mounting hole for protective earthing on the 
baseplate is properly connected, as required for class I equipment.  
 

3.2 Wiring output terminal 

The assembly torque for output terminal screws. 

Screw size 

 

: M6 

Recommended screw torque  : 3.8 Nm  

At -40°C operation, an external output capacitor needs to be added to 
ensure stable output voltage during start-up. Table 3.1 shows a 
recommended an external output capacitor. 
 
 

Table 3.1 Recommended external output capacitor 

Models 

Value 

OFI1200A12 

7,800 µF 

OFI1200A28 

3,000 µF 

OFI1200A48 

1,360 µF 

 

 

 

0

50

100

-40

-20

0

20

40

60

80

100

Loa

d fact

or 

[%

]

Baseplate

temperature [˚C]

(75)

(75)

OFI1200A28,OFI1200A48 
Vin = 170

305VAC

OFI1200A28,OFI1200A48 
Vin = 85

170VAC

(65)

(95)

OFI1200A12

(60)

Screw locations 

Содержание OFI1200A Series

Страница 1: ...ranty 11 6 1 Life Expectancy 11 6 2 Warranty 11 7 Options 11 7 1 Option N with Metal cover 11 7 2 Option O with Active ORing 11 1 Assembling and Installation Method 1 1 Mounting method OFI1200A series...

Страница 2: ...a load on an earthed metal plate Input cables should be twisted and places as close to the metal enclosure as possible Output cables of positive and negative should be twisted and shall be separated f...

Страница 3: ...s section solid 0 2 mm2 6 mm2 Connector cross section flexible 0 2 mm2 4 mm2 Conductor cross section AWG AWG 24 10 Conductor cross section flexible with ferrule 0 25 mm2 4 mm2 Stripping length 8mm Tor...

Страница 4: ...ipple noise measurement The specified ripple and ripple noise are measured by the method shown in Fig 3 3 Fig 3 3 Method of Measuring Output ripple and ripple noise Remarks When the ambient temperatur...

Страница 5: ...tivated and shut down the output When the thermal protection is activated turn off the input voltage and eliminate all the overheating conditions To recover the output voltage let the unit cool down b...

Страница 6: ...SHORT 0 5V max 5 Output OFF SW SHORT 2mA min SW OPEN 0 1mA max Fig 4 3 The Internal circuit and function of X601 a Use external voltage source Positive logic External resistor Rrc value shall be deci...

Страница 7: ...usted by connecting external resistors to ITRM or by applying a voltage externally Meanwhile the Hiccup mode of the short circuit protection will be disabled 1 Constant current adjustment by potentiom...

Страница 8: ...eration Series operation is possible by connecting the output of two or more power supplies as shown in Fig 5 1 Fig 5 1 Example of Series operation Output current in series connection should be lower...

Страница 9: ...or parallel operation Remarks Make sure that the wiring impedance of a load from each unit becomes even A voltage drop from Vout of unit to the connected point of terminal S should be less than 0 5V f...

Страница 10: ...not necessary to connect the ITRM terminals together Examples of connecting constant current circuit in parallel operation are shown in Fig 5 8 and Fig 5 9 Refer to section 4 9 Adjustable constant cu...

Страница 11: ...oltage adjustment range by external voltage source with the option O is shown as below Model Output Output Number Voltage Voltage adj OFI1200A28 O 28VDC 5 33 6VDC OFI1200A48 O 48VDC 5 57 6VDC WARNING...

Отзывы: