FORWARD 

You are now the proud owner of a Power Technology Southeast generator set, powered by an industrial 

Isuzu diesel engine. This generator set is a Part of Power Tech`s Tier 4 Final Generator product line. It is 

the engineered to the utmost quality standards and manufactured in a strict quality control environment 

and will assure you a long, satisfactory service. To have the best performance from your Power Tech 

Generator, please fully read and understand this manual. This manual is written to better provide “YOU” 

with the information you need to operate and maintenance your generator. This manual was up to date at 

time of printing/downloading, there may be changes not reflected in your manual. If there is any questions 

please contact Power Technology’s customer service dept. 

 

TO OUR CUSTOMERS 

Thank you for your purchase of a Power Technology Generator. In the event you experience a problem 

with your generator please contact the sales dealer, one of our authorized service centers or Power 

Technology’s Customer Service Department directly at 1-800-760-0027 from 8:00 a.m. to 5:00 p.m. EST. 

Please have the generator model and serial numbers available when you call. This will help expedite 

service and parts to you. Parts may be obtained directly through Power Technology and shipped the 

same day if ordered by 3:00 p.m. EST. 

 

Parts may be ordered any time at 

WWW.POWERTECHPARTS.COM 

 

 

 

To find a list of our dealers, scan 

the QR code below 

Содержание PTI-15SS-T4F

Страница 1: ...Generating Power to the World Page 1 of 25 PTI 15 20 T4F Operators Manual Power Technology Southeast 634 State Road 44 Leesburg FL 34748 8103 Phone 352 365 2777 Fax 352 787 5545...

Страница 2: ...des Starting and Stopping Methods 15 Engine Specifications 16 Engine Maintenance Schedule 17 Engine Oil Maintenance 18 Lubricating Oil Specifications 18 LUBRICATING OIL VISCOSITY 18 RECOMMENDATIONS 18...

Страница 3: ...Generating Power to the World Page 3 of 25 PTI 15 20 T4F Operators Manual FIELD COIL 23 BALANCE 23 BEARING 24 STATOR ASSEMBLY 24 TROUBLESHOOTING 25 TROUBLE 25 POSSIBLE CAUSE 25 SUGGESTED ACTION 25...

Страница 4: ...enerator This manual was up to date at time of printing downloading there may be changes not reflected in your manual If there is any questions please contact Power Technology s customer service dept...

Страница 5: ...hich have been subjected to alteration modification neglect or unauthorized repairs D Troubleshooting routine service tune ups replacement of filters belts coolant lubricants hoses clamps exhaust syst...

Страница 6: ...bligation to change units or parts previously manufactured Warranty registration card must be completed and mailed to Power Tech at the above address to validate the Warranty This is the only express...

Страница 7: ...ty regulations before you attempt to assemble or use this unit WARNING Indicates a potentially hazardous situation which may possibly result in serious injury or possible death CAUTION Indicates a pot...

Страница 8: ...torn or bulky clothing around machinery Entanglement in rotating parts controls or projections may cause persona injury Use additional safety items e g hardhat eye protection gloves etc as appropriate...

Страница 9: ...rly dispose of DO NOT mix gasoline or alcohol with diesel fuel The mixture can cause a fire EXHAUST GASES AND FIRE PREVENTION Engine exhaust fumes can be very harmful if allowed to accumulate Be sure...

Страница 10: ...ants engine oil etc DO NOT remove the radiator cap while the engine is running or immediately after stopping Wait approximately ten minutes for the radiator to cool before removing the cap Be sure the...

Страница 11: ...ing in the formation of harmful substances Only use anti freeze that is recommended and approved by Engine Manufacturer Be mindful of the environment Before draining any fluids be prepared to dispose...

Страница 12: ...aintenance after the engine radiator muffler or muffler cover has cooled off completely Always use the appropriate tools and jig fixture when performing any service work Be sure to understand and foll...

Страница 13: ...vel for proper Fill add if necessary Check for absence of water in fuel drain if necessary Check for absence of DTC or failures Check for absence of excessive fan belt looseness Using the PTG Series C...

Страница 14: ...ving around in the menu changing a settings value or changing the currently displayed parameter page Generator LED Green Engine running with no issues Amber Engine running with warnings Red Engine shu...

Страница 15: ...e remotely started Auto When in the Auto mode the engine waits to receive a start command Running When engine is Running the controller monitors engine parameters and waits to receive a stop command F...

Страница 16: ...1800rpm 30 Oil type SAE 10W 40 API Class Oil capacity 8 4 Qts 8L Cooling System Capacity 11 25 Qts 10 6L Air Filter P N 04FA2768 Primary Fuel filter P N 08FF4LE P Secondary Fuel Filter P N 08FF4LE S...

Страница 17: ...air fuel filters need to be changed Maintenance Service Item See notes Daily 150 Hour Interval 500 Hour Interval 1000 Hour Interval Remarks Engine Oil Level deterioration Leakage x Engine Oil Change...

Страница 18: ...Specifications API Class CJ 4 Engine Oil LUBRICATING OIL VISCOSITY RECOMMENDATIONS The minimum ambient temperature during cold engine start up and the maximum ambient temperature during engine operat...

Страница 19: ...zing and boiling See the tables below ETHYLENE GLYCOL Freeze Boil Concentration Protection Protection 50 Percent 36 C 33 F 106 C 223 F 60 Percent 51 C 60 F 111 C 232 F PROPYLENE GLYCOL Freeze Boil Con...

Страница 20: ...cations CHECKING RESERVOIR TANK COOLANT LEVEL At a Minimum of 25 Hours of Operation Ensure that the coolant level of the radiator reservoir tank is between the upper limit FULL and the lower limit LOW...

Страница 21: ...HOURS and SERVICE LOG THIS SERVICE LOG IS PROVIDED TO HELP YOU KEEP AN ACCUMULATIVE RECORD OF OPERATION HOURS ON YOUR GENERATOR SET AND THE DATES REQUIRED SERVICES WERE PERFORMED ENTER TIME TO THE NEA...

Страница 22: ...provided if desired by turning the Voltage Adjust Rheostat ELECTRONIC VOLTAGE REGULATION Electronic Voltage Regulator EVR also referred to as an Automatic Voltage Regulator AVR is a very reliable devi...

Страница 23: ...adjustment of the regulator sensing circuit ROTATING FIELD ASSEMBLY ROTOR The rotating field assembly consists basically of four members 1 the shaft assembly 2 the core assembly 3 the field coil damp...

Страница 24: ...nspection of the bearing is recommended at typical service intervals If signs of abnormal wear or leakage are observed the bearing should be replaced Never use liquids of any kind to clean the generat...

Страница 25: ...rol wiring and check crank connections Cranking fuse blown Replace fuse with new of identical size Engine cranks but doesn t start Out of fuel Check fuel level add fuel if necessary Fuse Blown Replace...