background image

ON

OFF

WARNING:

This Quick Reference Guide is not a substitute for reading the operator’s manual. To reduce the risk of injury or death, user must read and understand operator’s manual before using this product. All page references refer to 
the operator’s manual.

5

4

6

1

Connect devices to be powered by generator by following the steps below 

(see pages 8-9).

  Make sure the generator can supply enough continuous (running) and surge (starting) watts for the items you 

will power at the same time. See page 9 for how to calculate total amount of power needed. 

  Start the generator with nothing connected.

  Plug in and turn on the first load, preferably the largest load you have.

  Permit the generator output to stabilize (engine runs smoothly and attached device operates properly).

  Plug in and turn on the next load.

  Again, permit the generator to stabilize.

  Repeat previous two steps for each additional load.

IMPORTANT: Never add more loads than the generator capacity. Take special care to consider surge loads in 

generator capacity. 

(See pages 8-9.)

1

1

 

WARNING:

 

Do not connect to a building’s electrical 

system unless the generator and transfer 

switch have been properly installed and 

the electrical output has been verified by 

a qualified electrician. The connection 

must isolate the generator power from 

utility power and must comply with all 

applicable laws and electrical codes.

Only use OUTSIDE and

far away from windows,

doors, and vents.

NEVER use inside a home

or garage, EVEN IF doors

and windows are open.

Using a generator indoors CAN KILL YOU IN MINUTES.
Generator exhaust contains carbon monoxide. This is a 

poison you cannot see or smell.

When preparing to store the generator, allow the unit to cool for 30 minutes, then follow the guidelines listed 

on page 18.

1

Remove side cover and add entire bottle of lubricant provided to the generator 

(see page 13)

.

1

Put the on/off switch in the ON ( I ) position, and then add fuel (see pages 13 and 14).

1

Pull the starter grip until the engine runs  

(see page 14).

Pull the choke lever out to the start position  

(see page 14).

Allow engine to run for 15-30 seconds, then push 

choke in to RUN position 

(see page 14).

991000785

10-15-15 (REV:01)

Turn the on/off switch to OFF before adding lubricant.

Set unit on flat surface so engine is level.

Remove dipstick, wipe clean, put back in hole (but don’t screw in) and check lubricant level.

Put the on/off switch in the OFF ( O ) position 

(see page 14).

NOTICE:

 

Do not use E15 or E85 fuel in this product. It is a violation of federal law and will 

damage the unit and void your warranty. Only use unleaded gasoline containing up 

to 10% ethanol. 

CHOKE LEVER

(START)

CHOKE LEVER 

(RUN)

PROBLEM

POSSIBLE CAUSE

SOLUTION

Engine will not start.

On/off switch is 

OFF ( O )

.

No fuel.

Stale gasoline or water in gasoline.

Lubricant level is low.

 

 

 

Spark plug faulty, fouled, or improperly 

gapped.

Choke lever is in run position.

Engine stored without treating or draining 

gasoline, or refueled with bad gasoline.

Dirty fuel filter.

Turn on/off switch to 

ON (I)

.

Fill fuel tank.

Drain entire system and refill with fresh fuel. 

Engine is equipped with Low Oil Shutoff. If 

engine lubricant level is low, it must be filled 

before unit will start. Check engine lubricant 

level and fill, if  necessary.

Replace spark plug.

 

Pull the choke lever out to the start position.

Drain fuel and carburetor. Refuel with fresh 

gasoline. 

Contact a qualified service center.

Engine hard to start.

Water in gasoline. 

Weak spark at spark plug.

Drain entire system and refill with fresh fuel.

Contact a qualified service center.

Engine lacks power.

Dirty air filter.

 

Engine stored without treating or draining 

gasoline, or refueled with bad gasoline.

Check air filter element. Clean or  replace as 

needed.

Drain fuel and carburetor. Refuel with fresh 

gasoline. 

AC receptacle does not work.

Generator is overloaded.

Item plugged in is defective.

Remove loads and press the reset button.

Try a different item.

DC receptacle does not work.

Circuit protector engaged.

 

 

Item plugged in is defective.

Remove any load from the generator. Turn 

the auto idle switch to off, then depress the 

DC circuit breaker.

Try a different item.

Generator makes a “spark knock” or “ping-

ing” noise.

An occasional light “knocking” or “pinging” 

under heavy load is not a cause for concern. 

However, if the knocking or pinging occurs 

under normal load at a steady engine speed, 

the problem may be with the brand of gasoline 

being used.

Switch to a different brand of gasoline, making 

sure that the octane rating is 86 or higher. 

If problem continues, contact a qualified 

service center.

If problem persists after trying the above solutions, contact customer service or a qualified service center for assistance.

NOTICE:

As the equipment owner, you are responsible for the performance of the required maintenance listed in the 

Maintenance

 section It 

is recommended that you retain all receipts covering maintenance on your equipment. Neglecting or failing to perform the required 

maintenance may increase emissions, decrease fuel efficiency, degrade performance, cause irreversible engine damage and/or 

void your warranty.

Make the most of your purchase! Go to www.powerstroketools.com 

and register your new tool online. For questions about operating or 

maintaining your product, please call, 1-877-617-3501.

3

Put auto idle in OFF position

 (see page 14).

ON/OFF 

SWITCH (ON)

ON

OFF

ON

OFF

SM

ART

THR

OTTLE

BATTER

Y

CHAR

GE ONL

Y

ON

OFF

SM

ART

THR

OTTLE

BATTER

Y

CHAR

GE ONL

Y

ON

OFF

ON/OFF 

SWITCH (OFF)

15-30 S

15-30 S

2

Open the vent on the vented fuel cap

 (see page 14). 

PSi2100G QUICK REFERENCE GUIDE

IMPORTANT!

STARTING THE UNIT (CONTINUED)

USING THE GENERATOR

TROUBLESHOOTING

STORING THE UNIT

FIRST TIME ASSEMBLY

STARTING THE UNIT

STOPPING THE UNIT

AUTO IDLE 

(OFF)

Отзывы: