background image

 

POWX1110 

EN

 

Copyright © 2015 VARO 

P a g e

 | 

4

 

www.varo.com 

4  SYMBOLS 

In this manual and/or on the machine the following symbols are used: 

 

In accordance with essential 
safety standards of 
applicable European 
directives 

 

Class II - The machine is double 
insulated; Earthing wire is 
therefore not necessary. 

 

Denotes risk of personal 
injury or damage to the tool. 

 

Always wear protective gloves. 

5  GENERAL POWER TOOL SAFETY WARNINGS 

Read all safety warnings and all instructions. Failure to follow all warnings and instructions 
may result in electric shock, fire and/or serious injury. Save all warnings and instructions for 
future reference. The term "power tool" in the warnings refers to your mains operated (corded) 
power tool or battery operated (cordless) power tool. 

5.1 

Work area 

 

Keep work area clean and well lit. Cluttered and dark areas invite accidents. 

 

Do not operate power tools in explosive atmospheres, such as in the presence of 
flammable liquids, gases or dust. Power tools create sparks which may ignite the dust or 
fumes. 

 

Keep children and bystanders away while operating a power tool. Distractions can cause 
you to lose control.  

5.2 

Electrical safety 

Always check that the power supply corresponds to the voltage on the 
rating plate. 

 

Power tool plugs must match the outlet. Never modify the plug in any way. Do not use any 
adapter plugs with earthed (grounded) power tools. Unmodified plugs and matching 
outlets will reduce risk of electric shock. 

 

Avoid body contact with earthed or grounded surfaces such as pipes, radiators, ranges 
and refrigerators. There is an increased risk of electric shock if your body is earthed or 
grounded. 

 

Do not expose power tools to rain or wet conditions. Water entering a power tool will 
increase the risk of electric shock. 

 

Do not abuse the cord. Never use the cord for carrying, pulling or unplugging the power 
tool. Keep cord away from heat, oil, sharp edges or moving parts. Damaged or entangled 
cords increase the risk of electric shock. 

 

When operating a power tool outdoors, use an extension cord suitable for outdoor use. 
Use of a cord suitable for outdoor use reduces the risk of electric shock. 

 

If operating a power tool in a damp location is unavoidable, use a residual current device 
(RCD) protected supply. Use of an RCD reduces the risk of electric shock. 

5.3 

Personal safety 

 

Stay alert, watch what you are doing and use common sense when operating a power 
tool. Do not use a power tool while you are tired or under the influence of drugs, alcohol or 
medication. A moment of inattention while operating power tools may result in serious 
personal injury. 

 

Use safety equipment. Always wear eye protection. Safety equipment such as dust mask, 
non-skid safety shoes, hard hat, or hearing protection used whenever conditions require 
will reduce personal injuries. 

Содержание POWX1110

Страница 1: ...WARNINGS FOR PLANERS 5 7 ADJUSTMENTS SETTINGS 6 7 1 Remove the blades Fig 1 6 7 2 Install the blades Fig 2 6 7 3 Setting the planing depth Fig 3 6 7 4 Mounting and setting the parallel guide Fig 4 6 8...

Страница 2: ...POWX1110 EN Copyright 2015 VARO P a g e 2 www varo com 15 ENVIRONMENT 9 16 DECLARATION OF CONFORMITY 10...

Страница 3: ...1 V shaped groove 12 Parallel guide assembly 13 Clamping screw 14 Blade assembly 15 Spring loaded protective cover 16 Planer base rear 17 Auto retracting foot 18 L Depth guide 3 PACKAGE CONTENT LIST R...

Страница 4: ...lug in any way Do not use any adapter plugs with earthed grounded power tools Unmodified plugs and matching outlets will reduce risk of electric shock Avoid body contact with earthed or grounded surfa...

Страница 5: ...ools are dangerous in the hands of untrained users Maintain power tools Check for misalignment or sticking of moving parts breakage of parts and any other condition that may affect the power tool s op...

Страница 6: ...as 3 0 mm It is recommended that test cuts are made in scrap wood after each re adjustment to make sure the desired amount of wood is being removed by the planer Several shallow passes will produce a...

Страница 7: ...is 18 mm made in several passes up to 3mm each time The Maximum width of a rebate cut is 82mm and is determined by the setting of parallel guide assembly 12 Fit the L depth guide 18 and the parallel...

Страница 8: ...levant standard K 3 Acoustic pressure level LpA 94 dB A Acoustic power level LwA 105 dB A ATTENTION The sound power level may exceed 85 dB A in this case individual hearing protection shall be worn aw...

Страница 9: ...etration intentional damage on purpose or by gross carelessness inappropriate usage use for purposes for which the device is not suitable incompetent usage e g not following the instructions given in...

Страница 10: ...orized modification of the apparatus voids this declaration European Directives including if applicable their amendments up to the date of signature 2011 65 EU 2006 42 EC 2004 108 EC European harmoniz...