In this manual and/or on the machine the following symbols are used: 

 

Denotes risk of personal 
injury or damage to the tool. 

 

Wear eye protection 

 

Read manual before use 

 

Wear a mask In dusty 
conditions 

 

In accordance with essential 
requirements of the 
European directive(s) 

 

"Class II - The machine is 
double insulated; Earthing 
wire is therefore not 
necessary 

5  GENERAL POWER TOOL SAFETY WARNINGS 

Read all safety warnings and all instructions. Failure to follow all warnings and instructions 
may result in electric shock, fire and/or serious injury. Save all warnings and instructions for 
future reference. The term "power tool" in the warnings refers to your mains operated (corded) 
power tool or battery operated (cordless) power tool. 

5.1 

Work area 

 

Keep work area clean and well lit. Cluttered and dark areas invite accidents. 

 

Do not operate power tools in explosive atmospheres, such as in the presence of 
flammable liquids, gases or dust. Power tools create sparks which may ignite the dust or 
fumes. 

 

Keep children and bystanders away while operating a power tool. Distractions can cause 
you to lose control.  

5.2 

Electrical safety 

Always check that the power supply corresponds to the voltage on the 
rating plate. 

 

Power tool plugs must match the outlet. Never modify the plug in any way. Do not use any 
adapter plugs with earthed (grounded) power tools. Unmodified plugs and matching 
outlets will reduce risk of electric shock. 

 

Avoid body contact with earthed or grounded surfaces such as pipes, radiators, ranges 
and refrigerators. There is an increased risk of electric shock if your body is earthed or 
grounded. 

 

Do not expose power tools to rain or wet conditions. Water entering a power tool will 
increase the risk of electric shock. 

 

Do not abuse the cord. Never use the cord for carrying, pulling or unplugging the power 
tool. Keep cord away from heat, oil, sharp edges or moving parts. Damaged or entangled 
cords increase the risk of electric shock. 

 

When operating a power tool outdoors, use an extension cord suitable for outdoor use. 
Use of a cord suitable for outdoor use reduces the risk of electric shock. 

 

If operating a power tool in a damp location is unavoidable, use a residual current device 
(RCD) protected supply. Use of an RCD reduces the risk of electric shock. 

 

 

Содержание POW4060

Страница 1: ... and care 4 5 5 Service 4 6 ADDITIONAL SAFETY HINTS FOR SANDERS 4 7 ASSEMBLY 5 7 1 Attaching the sandpaper 5 7 2 Dust extraction 5 7 3 Auxiliary handle 5 8 OPERATING INSTRUCTIONS 6 8 1 Switching On off 6 8 2 Speed adjusting dial 6 9 WORKING WITH THE ROTATING SANDER 6 10 TECHNICAL DATA 6 11 NOISE 6 12 CLEANING AND MAINTENANCE 7 12 1 Cleaning 7 13 SERVICE DEPARTMENT 7 14 STORAGE 7 15 WARRANTY 7 16 E...

Страница 2: ...Dust extractor connection 8 Dust bag 9 Cable 2m 3 PACKAGE CONTENT LIST Remove all packing materials Remove remaining packaging and transit supports if existing Check the completeness of the packing content Check the appliance the power cord the power plug and all accessories for transportation damages Keep the packaging materials as far as possible till the end of the warranty period Dispose it in...

Страница 3: ...p children and bystanders away while operating a power tool Distractions can cause you to lose control 5 2 Electrical safety Always check that the power supply corresponds to the voltage on the rating plate Power tool plugs must match the outlet Never modify the plug in any way Do not use any adapter plugs with earthed grounded power tools Unmodified plugs and matching outlets will reduce risk of ...

Страница 4: ...er tool if the switch does not turn it on and off Any power tool that cannot be controlled with the switch is dangerous and must be repaired Disconnect the plug from the power source before making any adjustments changing accessories or storing power tools Such preventive safety measures reduce the risk of starting the power tool accidentally Store idle power tools out of the reach of children and...

Страница 5: ...te using the hook and loop system of the sanding paper and the sanding base plate Make sure the perforations in the paper coincide with those on the sanding base plate to ensure optimal dust collection The sandpaper should rest flush on the base plate and must not come loose Select sandpaper with the correct grain size You can be sure to find the right sandpaper among our product range see accesso...

Страница 6: ...hine and apply moderate pressure move it over the workpiece in circular Crosswise or lengthwise movements Use a coarse grained disk for rough sanding and a fine grained disk lot line sanding The best grain for a particular job is best ascertained by trial runs Important Wear a dust mask and goggles Protective gloves are recommended The sender must never be used for work on materials which contain ...

Страница 7: ...id humidity build up 15 WARRANTY This product is warranted as provided by law for a 24 month period effective from the date of purchase by the first user This warranty covers all material or production flaws excluding batteries chargers defective parts subject to normal wear tear such as bearings brushes cables and plugs or accessories such as drills drill bits saw blades etc damage or defects res...

Страница 8: ... ventilation slots carbon brushes serviced regularly etc Your purchase receipt must be kept as proof of date of purchase Your appliance must be returned undismantled to your dealer in an acceptably clean state in its original blow moulded case if applicable to the unit accompanied by proof of purchase 16 ENVIRONMENT Should your appliance need replacement after extended use do not discard it with t...

Страница 9: ...rds Any unauthorized modification of the apparatus voids this declaration European Directives including if applicable their amendments up to the date of signature 2011 65 EU 2004 108 EC 2006 42 EC European harmonized standards including if applicable their amendments up to the date of signature EN60745 1 2009 EN60745 2 4 2009 EN55014 1 2006 EN55014 2 1997 EN61000 3 2 2006 EN61000 3 3 2008 Keeper o...

Отзывы: