background image

 

POWX1751 

EN

 

Copyright © 2018 VARO 

P a g e

 | 

4

 

www.varo.com 

4  SYMBOLS 

In this manual and/or on the machine the following symbols are used: 

 

Before use, read the handbook 
carefully 

 

Warning, hot surfaces 

 

Wear ear guards and goggles 

 

Danger - automatic control (closed 
loop) 

 

Dangerous voltage 

 

Wear gloves 

5  GENERAL POWER TOOL SAFETY WARNINGS 

Read  all  safety  warnings  and  all  instructions.  Failure  to  follow  all  warnings  and  instructions 
may  result  in  electric  shock,  fire  and/or  serious  injury.  Save  all  warnings  and  instructions  for 
future reference. The term "power tool" in the warnings refers to your mains operated (corded) 
power tool or battery operated (cordless) power tool. 

5.1 

Work area 

 

 Keep work area clean and well lit. Cluttered and dark areas invite accidents. 

 

Do not operate power tools in explosive atmospheres, such as in the presence of 
flammable liquids, gases or dust. Power tools create sparks which may ignite the dust or 
fumes. 

 

 Keep children and bystanders away while operating a power tool. Distractions can cause 
you to lose control.  

5.2 

Electrical safety 

Always check that the power supply corresponds to the voltage on the 
rating plate. 

 

 Power tool plugs must match the outlet. Never modify the plug in any way. Do not use 
any adapter plugs with earthed (grounded) power tools. Unmodified plugs and matching 
outlets will reduce risk of electric shock. 

 

Avoid body contact with earthed or grounded surfaces such as pipes, radiators, ranges 
and refrigerators. There is an increased risk of electric shock if your body is earthed or 
grounded. 

 

 Do not expose power tools to rain or wet conditions. Water entering a power tool will 
increase the risk of electric shock. 

 

 Do not abuse the cord. Never use the cord for carrying, pulling or unplugging the power 
tool. Keep cord away from heat, oil, sharp edges or moving parts. Damaged or entangled 
cords increase the risk of electric shock. 

 

 When operating a power tool outdoors, use an extension cord suitable for outdoor use. 
Use of a cord suitable for outdoor use reduces the risk of electric shock. 

 

 If operating a power tool in a damp location is unavoidable, use a residual current device 
(RCD) protected supply. Use of an RCD reduces the risk of electric shock. 

 

 

Содержание 829580

Страница 1: ...vice 5 6 SPECIFIC SAFETY WARNINGS 6 6 1 Do s 6 6 2 Don ts 6 6 3 Things you should know 7 7 ASSEMBLY 7 7 1 Point to know when setting up the compressor 7 7 2 Fitting the wheels 7 7 3 Fitting the suppor...

Страница 2: ...RO P a g e 2 www varo com 12 CLEANING AND MAINTENANCE 10 12 1 Cleaning 10 12 2 Maintenance 10 13 TECHNICAL DATA 10 14 NOISE 10 15 STORAGE 10 16 TROUBLE SHOOTING 11 17 WARRANTY 12 18 ENVIRONMENT 12 19...

Страница 3: ...e instructions 2 DESCRIPTION FIG 1 2 1 Shroud 2 Pressure vessel 3 Wheel 4 Supporting foot 5 Quick lock coupling 6 Pressure gauge 7 Pressure regulator 8 ON OFF switch 9 Transportation handle 10 Pressur...

Страница 4: ...ractions can cause you to lose control 5 2 Electrical safety Always check that the power supply corresponds to the voltage on the rating plate Power tool plugs must match the outlet Never modify the p...

Страница 5: ...not force the power tool Use the correct power tool for your application The correct power tool will do the job better and safer at the rate for which it was designed Do not use the power tool if the...

Страница 6: ...placed on a stable horizontal surface 6 2 Don ts Never direct the jet of air towards persons animals or your body Always wear safety goggles to protect your eyes against flying objects that may be li...

Страница 7: ...r Avoid long air lines and long supply lines extensions Make sure the intake air is dry and dust free Do not set up the compressor in damp or wet rooms The compressor may only be used in suitable room...

Страница 8: ...the air hose 2 Press the trigger to operate the tool 3 The flow of air may be regulated by adjusting flow valve at the base of the handle 4 Ensure the air supply is clean and does not exceed 90psi wh...

Страница 9: ...ep the nailer pointed away from yourself and others and connect to the hose Position the nailer nose against work piece and pull the trigger Disconnect air supply in case a nail or stapler is jammed P...

Страница 10: ...ECHNICAL DATA Type POWX1751 Rated power 1 5hp 1100W Current take off 5A Power supply voltage 230 V 50 Hz Air intake 180l min Maximum pressure 8bar 116PSI Weight 22kg Tank capacity 50l Rotation speed 3...

Страница 11: ...compressor stops and restarts automatically after a few minutes Tripping of the thermal cutout due to overheating of the motor Clean the air ducts Ventilate the work area After a few attempts to resta...

Страница 12: ...etration intentional damage on purpose or by gross carelessness inappropriate usage use for purposes for which the device is not suitable incompetent usage e g not following the instructions given in...

Страница 13: ...us voids this declaration European Directives including if applicable their amendments up to the date of signature 2011 65 EU 2014 30 EU 2006 42 EC 2000 14 EC Annex VI LwA 95dB A 97dB A testing author...