(PVI-6000-OUTD-xx-AU Rev:1.0)
5.
MONITORING AND DATA TRANSMISSION
5.1.
User’s Interface Mode
WARNING
: The RS-485 cable must provide at least 600V protection.
Normally, the AURORA inverter operates automatically and needs no
particular supervision. When solar radiation is not enough to generate power for
the grid (for instance, at night), AURORA disconnects automatically and goes into
stand-by mode.
The operating cycle is resumed automatically the moment solar radiation becomes
strong enough. This is indicated by the LEDs.
Aurora inverter can provide operational data in the following ways:
LED indicators
Operational data on the LCD display
Data transmission on a dedicated serial RS-485 line. Data can be collected by
a PC or a data logger equipped with an RS-485 port. If an RS-485 line is
used, it may be convenient to use the AURORA RS-485/RS232 Serial
Interface Converter model number PVI-RS232485. An optional AURORA
Easy Control data logger is also available.
Data transmission via USB cable. This type of connection is typically used
when monitoring a single inverter and for maintenance purposes. To connect
the USB cable, remove the waterproof plug at the bottom end of the inverter
right wall (Fig.17).
Fig.17 USB port
Содержание AURORA PVI-6000-OUTD-AU Series
Страница 16: ...Page 16 of 89 PVI 6000 OUTD xx AU Rev 1 0 Fig 3C Integrated switch and diodes models...
Страница 39: ...Page 39 of 89 PVI 6000 OUTD xx AU Rev 1 0 Fig 18 Data Transmission Options...
Страница 43: ...Page 43 of 89 PVI 6000 OUTD xx AU Rev 1 0 KEY LED on LED blinking LED off Any one of the above conditions...
Страница 70: ...Page 70 of 89 PVI 6000 OUTD xx AU Rev 1 0...
Страница 88: ...Page 88 of 89 PVI 6000 OUTD xx AU Rev 1 0 CERTIFICATE OF CONFORMITY...
Страница 89: ...Page 89 of 89 PVI 6000 OUTD xx AU Rev 1 0...