USER’S MANUAL 

 

MNL105-153T 

Version 1.0 

 
 
 
 
 

 
 

Powering Life 

Содержание MNL105-153T

Страница 1: ...Line Interactive Uninterruptible Power Supply Unit 1 5kVATower Model 153T USER S MANUAL MNL105 153T Version 1 0 Powering Life...

Страница 2: ...allation instructions carefully before operating Follow all instructions warnings and cautions listed in this manual Failure to do so may cause injury or product damage not covered by the warranty App...

Страница 3: ...4 Navigating the Menus 13 4 5 RS 232 Computer Interface Port 16 4 5 1 DB9 Pin Assignment 16 4 6 Protecting a Fax Machine or Modem 16 4 7 Remote Control Display 17 4 8 Emergency Power OFF 17 4 9 Storin...

Страница 4: ...This page intentionally left blank...

Страница 5: ...Even when utility power fails this system will supply backup power See 6 Specifications for approximate backup times 1 1 Key Features STANDARD FEATURES Line interactive sine wave topology Intelligent...

Страница 6: ...with the rest Some of the information is very important while other information may be good to know To show the importance of each piece of information the following symbols and formatting convention...

Страница 7: ...normally the system will charge batteries to operate when utility power is unstable Battery charging from the utility supply provides a cost effective means of providing reliable uninterruptible powe...

Страница 8: ...te a clean stable AC sine wave to power even the most sensitive equipment Power will pass from the battery through the DC DC converter DC AC interver and static switch to provide output for the full l...

Страница 9: ...r future shipping and transport 2 2 Transporting Disconnect all power cables and power down the unit before moving it While moving the unit handle it carefully The combined weight of the unit and its...

Страница 10: ...This page intentionally left blank...

Страница 11: ...unit Could be exposed to flammable gases or corrosive liquids Will be cooler than 32 F 0 C or hotter than 104 F 50 C Will be exposed to clutter or objects that could block ventilation openings Cannot...

Страница 12: ...from being switched back ON again Connect the UPS only to a grounded wall outlet 2 Connect the unit to the device it will be powering by plugging one 1 end of the device s power cord into the INTegra...

Страница 13: ...cluded ELECTRICAL WARNING Always be careful while handling the UPS Batteries in the unit may emit electricity even when the unit is disconnected 3 4 Prestart Checklist The UPS is positioned correctly...

Страница 14: ...This page intentionally left blank...

Страница 15: ...eat and make sure that the system is not overloaded ELECTRICAL WARNINGS Do not expose the UPS to flammable gases or corrosive liquids Ensure that no liquids of any kind enter the UPS unit Caution Do n...

Страница 16: ...d event logs 2 Up Key Press to scroll the display upward 3 Down Key Press to scroll the display downward 4 Left Enter Key Press to enter the setting page and save the settings 5 Fault LED Red LED that...

Страница 17: ...inking to indicate that the inverter can be switched ON Start the unit by pressing and simultaneously for three 3 seconds until the buzzer beeps twice The Normal LED will illuminate that power is bein...

Страница 18: ...14 Power Innovations INTegral Line Interactive Uninterruptible Power Supply 1 5kVA T 1 Rated Specification Menu 2 Status Menu 3 Voltage Menu 4 Frequency Menu...

Страница 19: ...tes issues occurring during the unit s current uptime Old Rec indicates issues occurring during the previous uptime AC Fail indicates events during which the system has gone into backup mode OV Load i...

Страница 20: ...wing Input Voltage Indicates the present input voltage to the UPS unit when AC power is present Output Voltage Indicates the present output voltage of the UPS AC Frequency Indicates the actual output...

Страница 21: ...5or 6 The unit will register changes made from up to distances of 100 feet It will be possible to view the input and output voltage or adjust the settings while away from the unit Any changes made to...

Страница 22: ...not be used for extended periods of time If the UPS is stored for longer than three 3 months plug it back into a power supply for at least 24 hours to fully restore the battery charge before use Caut...

Страница 23: ...ould cause accidental injury or death Follow the troubleshooting guide below If troubleshooting does not fix the problem call Power Innovations 5 2 1 Utility Power Functioning Scenario Possible Cause...

Страница 24: ...re Reducing the critical load to extend backup time AC input may not be connected correctly Checking the input rate Checking power connection AC utility fails UPS is in battery backup mode Buzzer beep...

Страница 25: ...INTegral Line Interactive Uninterruptible Power Supply Unit 1 5kVA T Power Innovations 21 This page intentionally left blank...

Страница 26: ...tery Mode 110 150 for 30 seconds 150 for 200ms then UPS shuts down Short Circuit Protection Line Mode Circuit breaker Battery Mode Electronic circuit DC Start Cold Start Yes Transfer Time Typical 4 ms...

Страница 27: ...INTegral Line Interactive Uninterruptible Power Supply Unit 1 5kVA T Power Innovations 23 This page intentionally left blank...

Страница 28: ...system contains batteries with a high short circuit current Even when disconnected from outlet power UPS components are still connected to batteries Incorrect battery handling may cause accident elect...

Страница 29: ...INTegral Line Interactive Uninterruptible Power Supply Unit 1 5kVA T Power Innovations 25 This page intentionally left blank...

Страница 30: ...d products for repair or replacement of that portion or part Replacement parts or unit may be new or refurbished and will meet specifications or the original parts or unit 8 1 3 Restrictions 8 1 3 1 P...