background image

Instruction and Operating 

Manual 

Safe Area Limit Switch Box

LSB-1000 Series 

 Ver. 1.0  

Содержание LSB-1000 Series

Страница 1: ...Instruction and Operating Manual Safe Area Limit Switch Box LSB 1000 Series Ver 1 0 ...

Страница 2: ...cautions 2 Overview of Structure 3 Product Specifications Features 4 Name Plate 5 Part Numbering System order code 6 Specifications of Switch and Sensors 6 1 Mechanical Switch 6 2 P F Proximity Sensors NJ2 V3 N 7 Wiring 8 Adjusting Switch and Cam 9 Dimensions 3 4 5 5 6 7 8 9 10 ...

Страница 3: ...ay become unsafe if handled incorrectly The assembly operation and maintenance of machines or equipment including our products must be performed by an operator who is appropriately trained and experienced 3 Do not service or attempt to remove product and machinery equipment until safety is confirmed 1 The inspection and maintenance of machinery equipment should only be performed after measures to ...

Страница 4: ...ty a replacement product or necessary parts will be provided This limited warranty applies only to our product independently and not to any other damage incurred due to the failure of the product 3 Prior to using POWER GENEX products please read and understand the warranty terms and disclaimers noted in the specified catalogue for the particular products Note 2 Vacuum pads are excluded from this 1...

Страница 5: ...s 2 Make sure fingers do not get caught when mounting and aligning the cam Cut off the pressure supply and always release the compressed air inside the Switch Box and actuator before performing this work 3 Always flush the pipe s inside before piping to ensure foreign objects such as machining chips do not enter the Switch Box 4 The actuator opening may become unstable when using the booster relay...

Страница 6: ...a plug should be put in the piping port and a body cover unit fitted to avoid water penetration Take measures to avoid dew condensation inside the positioner if exposed to high temperature and humidity Take enough measures against condensation especially when packing for export 4 Keep magnetic field off the positioner as this affects its characteristics Operating Environment Caution 1 Do not opera...

Страница 7: ...l P F Proximity Sensor NJ2 V3 N Autonics Proximity SensorPSN17 D Honeywell SPDT limit Switches NAMUR Mounting Shaft and Brackets Below are descriptions and the internal view of the product with open cover No Description 1 LSB1000 Body 2 Switch Sensor 3 Switch Cam 4 Socket Terminal 5 Wire Connector 6 Bracket 1 4 6 2 3 5 ...

Страница 8: ...witch 2 SPDT Hermetically sealed magnetic Sensor 2 MS 20 Operating Temperature 40 100 40 212 Electrical Connections PF1 2 NPT 1 2 M20x1 5 PG13 5 Body Materials Aluminum Die cast Weight 0 8kg Non Explosion proof type IP67 IP68 Switch Box Made with solid Aluminum Die Casting Material 4 Nameplate Model LSB 1000 Switch Shows Switch Sensor type Ratings Shows rated voltage Current LSB 1000 Mechanical sw...

Страница 9: ... Dustproof IP67 7 Waterproof Dustproof IP68 8 Beacon Indicator Not Included N Beacon Indicator 90 open close A L or T Port Indicator D Electrical PF 1 2 C Connections NPT 1 2 D M20x1 5 E PG 13 5 H No of Electrical Connections 2 pcs 2 Feedback Shaft Rotary Type NAMUR Shaft N Fork Lever F Linear Type Stroke 10 40mm A Stroke 10 80mm B Stroke 80 150mm C Stroke 80 200mm D Mounting Bracket Non N 30 x 80...

Страница 10: ...e Allowed Voltage 125VAC 250VAC 277VAC 125VDC 250VDC 15 1A 1 2HP 15 1A 1 2HP 15 1A 1 2HP 0 5A 0 25A Connection Diagram Operating Temperature 40 82 6 2 P F Proximity Sensor NJ2 V3 N Proximity Sensor Standard Features Switching Functioning Factor Detection Range Installation Output polarity Certified Detection range NAMUR NC 2mm Built in NAMUR 0 1 62 mm Nominal Ratings Nominal voltage Switching Freq...

Страница 11: ...ectly before connection SPDT Mechanical Switch Autonics 3 Wire Proximity Sensor P F 2 Wire Proximity Sensor CLOSE NC GROUND MECHANICAL SWITCH SWITCH OPEN SWITCH CLOSE C NO NO C NC BLUE BLACK RED YELLOW WHITE GREEN 6 7 2 1 3 4 5 OPEN 8 EXT SOLENOID VALVE GROUND PROXIMITY SWITCHS 5 OPEN GROUND 1 4 2 3 CLOSE LOAD 6 LOAD BU BN BK BU BN BK SWITCH OPEN SWITCH CLOSE GROUND PROXIMITY SWITCHS 5 OPEN GROUND...

Страница 12: ... position of the Cam b Pull the Cam up as shown on the diagram to turn c Turn the Red Cam to a position where user wishes to operate limit switches and push the Cam down to adjust d Blue Cam can be turned by pulling downward and place it on a positioner where user wishes to operate limit switches ...

Страница 13: ...LSB 1000 Series jjautomation com 13 9 Dimensions Bracket Size ...

Страница 14: ...00 Series jjautomation com 14 J J Automation UK Ltd Units 5 6 Lime Tree Business Park Matlock Derbyshire DE4 3EJ U K Tel 44 1629 55577 Home Page http www powergenex com Subject to change without prior notice ...