Power Fist 8626632 Скачать руководство пользователя страница 1

V4.0 

8626632 

Please read and understand all instructions before use. Retain this manual for future reference. 

SPECIFICATIONS 

Amperage Rating 

15A 

Voltage Rating 

125V 

Pole-Wire 

2 Pole, 3 Wire 

NEMA Configuration  5-15R 
Material 

PBT body (white) and nylon 
housing (black). 

The 15A 125V female plug is a replacement for damaged 
plugs. 

SAFETY 

WARNING! Read and understand all instructions before 
using this tool. The operator must follow basic precautions 
to reduce the risk of personal injury and/or damage to the 
equipment. 

Keep this manual for safety warnings, precautions, operating or 
inspection and maintenance instructions. 
1.  Operate in a safe work environment. Keep your work area 

clean, well-lit and free of distractions. Place lights so you are 
not working in a shadow. 

2.  Control the tool, personal movement and the work 

environment to avoid personal injury or damage to tool. 

3.  Do not operate any tool when tired or under the influence of 

drugs, alcohol or medications. 

4.  Always wear impact safety goggles that provide front and side 

protection for the eyes. Eye protection equipment should 
comply with CSA Z94.3-07 or ANSI Z87.1 standards based on 
the type of work performed. 

5.  Wear protective clothing designed for the work environment 

and tool.  

6.  When wiring an electrically driven tool, follow all electrical 

and safety codes, as well as the most recent Canadian 
Electrical Code (CE) and Canadian Centre for Occupational 
Health and Safety (CCOHS). 

7.  Never modify the plug in any way, as this will render the 

tool unsafe.  

8.  Keep all connections dry and off the ground to reduce the risk 

of electric shock. Do not touch the wiring with wet hands. 

UNPACKING  

WARNING! Do not operate the tool if any part is missing. 
Replace the missing part before operating. Failure to do so 
could result in a malfunction and personal injury. 

Remove the parts and accessories from the packaging and 
inspect for damage. 

IDENTIFICATION KEY 

A  Opening, Neutral  
B  Opening, Live  
C  Plug Housing 
D  Clamp  
E  Opening, Ground 
F  Body 
G  Terminal Screw 

ASSEMBLY & INSTALLATION 

1.  Remove both terminal screws (G). 
2.  Separate both halves of the plug body (C). 
 
 
 

3.  Strip the cable jacket (Fig. 2-1) 

from the last inch of a 
SJT#14AWG electrical cable.  

4.  Strip a 1/2 in. of wire insulation 

off each wire (Fig. 2-2), leaving 
bare copper wire (Fig. 2-3). 

5.  Connect each wire to the appropriate terminal. Do not use 

solder or tin on the connection.  
a.  Connect the black wire to the live terminal receiver (B). 
b.  Connect the blue or white wire to the neutral receiver (A). 
c.  Connect the green or green and yellow wire to the 

ground receiver (E). 

6.  Push both halves of the plug body together so the 

electrical cable jacket is secured in the clamp (D). 

7.  Tighten both terminal screws to 14 in-lb (1.6 N-m). 

CARE & MAINTENANCE  

1.  Maintain the tool with care. A tool in good condition is 

efficient, easier to control and will have fewer problems. 

2.  Inspect the tool components periodically. Repair or replace 

damaged or worn components. Only use identical 
replacement parts when servicing. 

WARNING! Only qualified service personnel should repair the 
tool. An improperly repaired tool may present a hazard to the 
user and/or others. 

15A 125V Female Connector 

Fig. 1

 

Fig. 2

 

Отзывы: