SDRIVE 700
POWER ELECTRONICS
40
VISUALIZATION AND STATUS PARAMETERS. GROUP G0
9.
VISUALIZATION AND STATUS
PARAMETERS. GROUP G0
These parameters constantly indicate the input signal status and dynamic parameter status of the SD700.
Visualization lines are the second and the third lines. The user can select the parameter to be displayed in
each line from the different visualization options.
To select a display parameter you should move to the cursor to the second or third line. For this, you need
to press
ESC /
↑
↓
key for approx two seconds. The cursor moves from one line to the next. Once
located on the second or third line you can navigate like the programming line (line 4) and select the
desired parameter to be displayed. Once selected these parameters are saved into memory. These
parameters are then displayed on lines 2 and 3 whenever the drive is powered up.
Thanks to these lines user can display desired parameters and obtain additional information easily.
Figure 9.1 Visualization Lines Description
9.1.
Parameters SV.1 – Motor Visualization
Screen
Units
Description
Sp Ref =+100%
% motor
speed
It shows the preset reference value of speed which is applied to the motor.
Mtr Speed = +0rpm
rpm
It shows the motor speed in revs per minute.
Mtr Freq = +0Hz
Hz
It shows the frequency being applied to the motor.
Mtr Vout = 0V
V
It shows the present voltage applied to the motor.
Mtr Iout = 0.0A
A
It shows the present current flowing to the motor.
Mtr Torqe = 0.0%
% Motor
torque
It shows the present torque applied to the motor.
Mtr Pfactr = 0.0
-
It shows the power factor of the motor.
Mtr Pwr = +0.0kW
kW
It shows the instantaneous power consumption of the motor.
0.0A 0.0A 0.0A
A
It shows the instantaneous current of each phase of the motor (U, V and W).
Vmt= 0 0 0V
V
It shows the instantaneous voltage applied to the motor terminals.
PTC Motor = 0
-
It shows if the motor PTC (temperature sensor) is connected.
X: PTC Connected.
0: PTC Not Connected.
Motor Temp = 0.0%
% Motor heat
It shows the estimated motor temperature. A level of 110% will cause an F25 trip
(motor overload).