Installation
01.4IB.48041
B. S
ecure
p
roBe
to
l
ocAtion
of
i
ntereSt
The most common probe mounting fixture for
use with the BriteSpot® Plus system is based on
industry standard ring-style cable termination
lugs. These lugs have proven to be reliable,
easy to install, and virtually maintenance free.
In addition, if installed at locations with existing
hardware, no modifications to hardware
lengths or specifications are needed. The fiber
probe has a special feature, called the “probe-
lock” which secures the probe to the lug
without crimping, allowing lugs to be installed
first, then the attachment of the probe.
Figure 7
FIber-Optic Probe with Probe Lock
Probe Lock Setscrew
1. Select the proper lug of the application
based on the existing hardware (if present)
or planned hardware. If purchased in kit
form, ½ inch lugs have been included.
Other sizes are also available as seen in
. When selecting the lug for a
given location, ensure that the lug with the
tightest fit around the hardware is selected
- this aids in proper thermal conduction and
will result in more accurate readings.
Figure 8
Tyco/Amp Ring Style Lugs
a
b
c
a.
½
” Hardware (Tyco/Amp PN 36808)
b.
3
/
8
” Hardware (Tyco/Amp PN 36807
c.
¼
” Hardware (Tyco/Amp PN 33465)
2. To make probe installation easier,
consideration must first be given to the
rotational orientation of the lug prior to
mounting. When the probe is eventually
installed, the fiber will need to have a
relatively unobstructed path to be inserted
into the lug. For example, in some situation
protective boots are placed over bolted
connections, posing an inconvenience
when routing the fiber. Align the fixture
to allow the fiber to be threaded through
existing seams in the dielectric boot. The
lug must also be placed such that the
“probe-lock” is accessible to an Allen key for
tightening.
3. Mount the lug so that it is directly
contacting the surface to be measured.
Washers should NOT be placed between
the lug and the surface to be measured;
instead they should be placed on the other
side of the lug, as shown in
.
shows the proper installation
when Belleville washers are used.
Absolutely no greases and/or pastes should
be used between the lug and the surface
it is contacting. Ensure the orientation of
the lug is such that the probe and fiber run
parallel to the bus.
Содержание BriteSpot Plus
Страница 4: ...Powered by Safety 01 4IB 48041 BriteSpot Plus This page is left blank intentionally ...
Страница 29: ...Powered by Safety 19 Installation 01 4IB 48041 Figure 20 Panel Mount Clip Installation X X ...
Страница 57: ...Powered by Safety 47 Appendix A 01 4IB 48041 Figure 64 10250 BSPL 18C1P1E0X0 Dimensions ...
Страница 58: ...Powered by Safety 48 Appendix A 01 4IB 48041 BriteSpot Plus Figure 65 10251 BSPL 09C1P E0X0 Dimensions ...