Powered by Safety
®
54
Recommended Renewal Parts and Replacement Procedures
PowlVac® ARG & ARM Series 4 Vacuum Circuit Breakers
5kV & 15kV - 1200A, 2000A, & 3000A - 25kA, 36kA, 50kA, & 63kA
01.4IB.60306
8) Anti-Pump Relay Assembly
Refer to service manual
01.4SM.1000
Anti-Pump Relay Assembly
for replacement
and installation procedures.
9) Latch Check Switch
Refer to service manual
01.4SM.1400 Latch
Check Switch Assembly
for replacement and
installation procedures.
10) Motor Cutoff Switch Assembly
Refer to service manual
01.4SM.1500 Motor
Cutoff Switch Assembly
for replacement and
installation procedures.
11) Auxiliary Switch
Refer to service manual
01.4SM.1100
Auxiliary Switch Assembly
for replacement
and installation procedures.
12) Ground Connection Assembly
This assembly is located at the rear edge
of the floor pan of the circuit breaker,
between the center and right poles of the
circuit breaker (
).
a. Elevate and secure the circuit breaker so
there is at least 6 inches of clear space
under the circuit breaker base pan.
b. Remove the bolt holding the retaining
clip to the ground connection mounting
bracket, and remove the retaining clip.
c. Slide the assembly slightly forward,
so that the ends of the mounting rods
on each side of the assembly is clear
of the holes in the ground connection
mounting bracket. Press down on the
assembly and remove it from bottom of
circuit breaker.
d. Remove the two red spacer tubes from
the socket head screws which holds the
assembly together.
e. Assemble the new assembly with the
red spacer tubes and torque to
8-12 ft-lb.
f. Wipe the old lubricant off the ground
connection mounting bracket on the
circuit breaker, and apply a thin coat
contact lubricant Mobilgrease 28 to
the mounting bracket. Insert the new
assembly from below the circuit breaker
floor pan and press up and slide back
until the mounting rods can be inserted
into the holes in the ground connection
mounting bracket.
g. Reinstall the retaining clip
13) Racking Motor
The racking motor should only be replaced
by a qualified person or a Powell Service
technician. Contact Powell for further
assistance at 1.800.480.7273.