background image

ENGLISH | 11

PROPER STORAGE

Preparing your Portable Power Steam Cleaner for storage is quick and simple. When you have fin-

ished your steaming tasks, follow the steps listed below.

1.

 Set Lighted On/Off Switch to “

O

” (off) position and unplug power cord from electrical outlet.

2.

 Allow unit to cool (30 minutes for complete cooling).

3.

 Press and hold Steam Trigger to release all remaining steam pressure.

4.

 Remove all accessories from unit.

5.

 Unscrew and remove Reservoir Cap. Drain any remaining water from Reservoir into a sink or tub – 

    this will help to minimize mineral build-up and prevent over-filling during your next use.  

    Loosely replace Reservoir cap.
    

NOTE: Do not overtighten Reservoir Cap when storing, as this may make it difficult to remove 

    during next use.
6.

 Store accessories safely away - smaller accessories can be conveniently stored in the storage 

    compartment located on the Cord Wrap.

7.

 Loosely wrap power cord around Cord Wrap and store Portable Power Steam Cleaner in a cool, 

    dry location.

CARE & MAINTENANCE

A common maintenance need for steam appliances is the removal of build-up caused by high

mineral content in many municipal water supplies. This mineral build-up may limit the

effectiveness and reduce the life of your Portable Power Steam Cleaner.

The best way to minimize mineral build-up is to use distilled or de-mineralized water when

using your Portable Power Steam Cleaner.

 If you are unable to use distilled water, it is recommended 

that the following procedure be followed monthly to help remove any mineral build-up:

To remove mineral build-up:

1.

 Set Lighted On/Off Switch to “

O

” (off) position and unplug power cord from electrical outlet.

2.

 Allow unit to cool (30 minutes for complete cooling).

3.

 Press and hold Steam Trigger to release all remaining steam pressure.

4.

 Remove all accessories from unit.

5.

 Unscrew and remove Reservoir Cap, and drain any remaining water from Reservoir into a sink or 

tub.

6.

 Fill Measuring Cup with 16 oz (474 ml) distilled vinegar. Carefully pour vinegar into Reservoir.

7.

 Slowly shake or move unit around to agitate vinegar.

8.

 Allow to stand for at least 40 minutes, or more if possible.

9.

 Drain vinegar from Reservoir.

10.

 Rinse Reservoir with fresh water, drain and repeat until vinegar odor dissipates.

11.

 Loosely replace Reservoir Cap and continue with normal storage procedure, as outlined in 

      

Proper Storage

 section above.

Storage & Care

Содержание PP270

Страница 1: ...P O R T A B L E P O W E R S T E A M C L E A N E R O W N E R S G U I D E PP270...

Страница 2: ...k do not immerse unit in water or other liquids Do not use power cord as handle let it hang over edges of counters or be crimped or closed in doors 6 Never yank power cord to disconnect from outlet in...

Страница 3: ...osely when storing 23 Always allow unit to cool at least 30 minutes for complete cooling and empty Reservoir before storing Do not store unit with a damp Microfiber Pad still attached 24 This product...

Страница 4: ...for Consumer Service contact information UNIT FEATURES ACCESSORIES Steam Hose Main Nozzle Steam Trigger Steam Trigger Lock Steam Handle Handle Cradle Cord Wrap Reservoir internal Reservoir Cap Lighted...

Страница 5: ...the first Wand Both Exten sion Wands should now be connected to the Main Nozzle MOP HEAD 1 Align Mop Head with open end of Extension Wand so that hole in Mop Head aligns with yel low lock release but...

Страница 6: ...heat or air dry setting is acceptable as well The Mop Head and Microfiber Pads are perfect for use on these hard floor surfaces IMPORTANT Do not use on unsealed hardwood or unglazed ceramic surfaces...

Страница 7: ...be connected to the end of an Extension Wand for reaching high or difficult spots Connect the Extension Wand or Wands as outlined on Page 8 then connect your Jet Nozzle to the Wand in the same way as...

Страница 8: ...picuous spot before proceeding Jet Nozzle Dirt Grease Grime Cracks and Crevices Golf Clubs Tread of Running Shoes Nylon Utility Brush and Round Brush Ovens Stove Tops Faucet Fixtures Microwaves Sports...

Страница 9: ...mineral build up 6 Carefully pour water from Measuring Cup into Reservoir through fill hole 7 Depending on how long you intend to steam you may repeat steps 5 6 up to two more times up to a maximum o...

Страница 10: ...e Steam Trigger until Steam Indicator Light turns blue again 7 To effectively kill bacteria and other microorganisms hold Main Nozzle and any connected accessories approximately 1 2 inch from surface...

Страница 11: ...used by high mineral content in many municipal water supplies This mineral build up may limit the effectiveness and reduce the life of your Portable Power Steam Cleaner The best way to minimize minera...

Страница 12: ...nance section on Page 11 for details Excessive amount of water in steam NOTE Unit produces moist steam it is normal for steam to contain some amount of water Water condensation in Steam Hose Point noz...

Страница 13: ...fast a division of Vornado Air LLC Steamfast Subject to the terms and conditions of this 2 Year Limited Warranty Warranty as set forth below Steamfast warrants to the original consumer or purchaser Bu...

Страница 14: ...arranty within sixty 60 days following date of purchase Buyer may either visit Steamfast s website at www Poulan Prosteam com and complete an online application or mail a completed application to Stea...

Страница 15: ...Poulan Pro 415 East 13th Andover KS 67002 1 800 711 6617 poulanprosteam com help poulanprosteam com T270 005 R V01...

Отзывы: