GB
5 Multitronic II main menu for VITASEM
Three different functions can be activated via this menu:
Seed drill unit default settings <
Grnd
>
Sensor test <
SEns
>
Calibration assistance <
Abdr
>
Press the F key and use arrow key
A
or
V
to select the desired function.
Press the
F
key again to activate the selected function.
5.1 Default settings
The default settings must be established before the seed drill monitor can be used for the
first time. This operation allows the seed drill monitor to receive data on the configuration
of the seed drill unit.
Erroneous default settings lead to functioning errors and incorrectly
calculated readouts.
Press the
F
key and use
A
or
V
to select the default setting. Press the F key again to
activate the default setting. This operation displays the tramline rhythm setting.
5.1.1 Tramline rhythm
This menu allows adjustment of the symmetric and asymmetric tramline rhythms, or
deactivation of the tramline circuit.
Symmetric tramline rhythms:
<
SY:02
>,
03
,
04
,
05
,
06
,
07
,
08
,
09
,
10
,
11
,
12
Asymmetric tramline rhythms:
<
AS:02
>,
04
,
06
,
08
,
10
,
12
Deactivated tramline circuit: <
FG:00
>
Use
A
or
V
to select the tramline rhythm and press F to save. (See sect. 5.1.7)
The next stage is adjustment of the seed drill unit operating width
5.1.2 Operating width
The operating width symbol <
LArG
> is now displayed and, after three seconds, the
previously set operating width.
Use
A
or
V
to select the operating width and press
F
to save. (See sect. 5.1.7)
The following stage is hectare meter calibration.