- 63 -
1100-GB SERVICE_2441
GB
SERVICE
Emergency menu
Menu function:
If the control is in an indefinable situation (e.g. defective sensor) all valves can be selected key wise through the
emergency menu.
ISOBUS
T1
Lift all rotary units to transport position
T2
Lower all rotary units to working position
T3
Reset button
T4
Hardware information
T5
Decrease working width
T6
Stop
T7...T9
Preselect – rotary unit(s)
T10
Increase working width
• Select working position or transport position
manually:
- Press “Stop” button for 10 secs. to come to
emergency menu.
- Preselect required rotary unit (buttons T7…T9)
- Button (T5) to minimize working width
(Minimizing rear rotary units additionally opens
transport locking brackets)
- Button (T10) to increase working width
- Button (T1) to lower to working position
- Button (T2) to lift to transport position
- Button (T3) to reset. Job calculator accepts current
port position as the working position.
- Press (T6) button for 10 secs. to leave emergency
menu.
T6
T7
T8
T9
T10
SET
T1
T2
T3
T4
T5
Power Control
• Select working position manually:
-
Press “Stop” button for 10 secs. to come
to emergency menu.
- Preselect required rotary unit
-
Button (-) to minimize working width
(Minimizing rear rotary units additionally
opens transport locking brackets)
-
Button (+) to increase working width
-
Button (1) to lift to transport position
-
Button (2) to lower to working position
-
Press button “Menu” for 5 seconds. Job
calculator accepts current position as the
working position.
-
Press “Stop” button for 10 secs. to leave
emergency menu
Hinweis:
Wenn die Kreiselarme noch mit dem Transportverriegelungshaken gesichert sind, so müssen die Kreisel
vorher kurz gehoben werden. Damit ist sichergestellt, dass die Kreisel nicht mit dem Eigengewicht
im Verriegelungshaken hängen und dieser zuverlässig öffnen kann.