Check tensioner pulley run
Check the tensioner pulley running after the initial operation
and after every change to the drive. The tensioner pulley
must run parallel to the drive belt (see illustration).
Lubricating the drive:
After every 50 operating hours: with grease
• SP1
• SP 2
224-16-05
Gear oil:
(After every 100 operating hours)
The gearing is located on the right side of the conditioner.
CS
AS
• Open drain plug (AS) and drain oil
• Pour gear oil (700ml) in filling screws (BS)
• (CS) = Filling level screw
(Fully synthetic lubricating oil for high-
temperature lubrication, ISO-VG class 220)
- 33 -