- 61 -
0602-GB-ELEKTRoHYDRAULIK_563
GB
Function check for ”Select Control”
operating unit and job calculator
* Checking the ”Select Control” operating unit!
- Connect power supply with12V on-board voltage
- Turn operating unit on by pressing ”I/O”.
- LED (1) in I/O button lights up for 2 seconds.
- If properly linked to job calculator, LED (1) lights up
in I/O button
- If improperly linked to job calculator, LED begins to
blink after 2 seconds.
- If LED (!) does not light up
- check voltage supply (cable)
- operating unit is defective.
* Checking the Job calculator
- Connect power supply with 12V on-board
voltage
- Blinking LED (2) on job calculator board lights up
for 1 second
- Software version appears on display for 5
seconds
- After that there are alternate displays of the
- operating hours (if sensors are provided) and
- status of the sensors
- Activate job calculator by pressing I/O button on
the operating unit
- Blinking LED (2) on job calculator board blinks in 2
second phases
- Press relative function button on job calculator
board
- Function display through LEDs (X7.1 to X8.7) for
each power outlet
Sensor diagnostic function
- For every sensor a vertical bar is shown on the
display
- long bar = active sensor (sensors recognizes
metal)
- short bar (sensor has no contact to metal)
Example: Sensor X1.11 is active = large bar (2 lines)
zB.:
Display for Software version
- after power has been connected
- software version is displayed for 5 seconds
(codification)
number of software version
Type: L = LW Select Control
P = LW Direct Control
Jobrechner
Attention!
Take care! When
opening the
casing do not
damage the seal.
elecTro-hydraulics