47
15.0 FAULT FINDING
Publication No. 5111813
Check and correct if necessary
1. Electrical and pressure tube connections
2. Blockage of pressure tubes
3. Restriction in flue
4. Venturi
NO
E
Replace air
pressure switch
Gas at burner
Ensure gas is on and purged
Replace main PCB
Replace gas valve
neon flashing
PCB - A1 connector has 230V
across terminals 2 & 4
YES
Turn selector switch
to reset position
YES
NO
NO
NO
F
Replace main PCB
G
Check and correct if necessary
1. Ignition electrode and lead
2. Electrode connection
3. Spark gap and position
230V at Main PCB - A1
connector across terminals
3 & 5. Check wiring
YES
NO
Replace gas valve
electrical plug &
igniter assembly
YES
H
YES
Check the burner setting pressure at the gas
valve (see Section 9.2 of Commissioning)
1.
Voltage at modulating coil of gas valve is:
Max. burner press.approx 9V DC (13V DC LPG)
Min. burner press.approx 1V DC
Current at modulating coil of gas valve is:
(Use an instrument with average function for this
measure)
30 ÷ 230 mA DC (45 ÷ 310 mA DC - LPG gas)
Replace gas valve
NO
Replace main PCB
2.
Fault Finding Solutions
Содержание Performa 24i HE
Страница 49: ...49 16 0 NOTES Publication No 5111813 ...
Страница 50: ...16 0 NOTES 50 Publication No 5111813 ...
Страница 51: ...51 Publication No 5111813 ...