
Prog. no.
Level Standard value
304:Controller stop
Boiler temp
Outside temp
Domestic water temperature
Collector temp B6
24-hour yield solar energy
Total yield solar energy
Solid fuel boiler temp
Buffer temperature
Swimming pool temp
State heating circuit 1
State heating circuit 2
State heating circuit 3
State DHW
State boiler
State solar
State solid fuel boiler
State buffer
State swimming pool
Year
Date
Time
Telephone customer service
Water pressure
(1) The display of the information values depends on the operating Status!
9.2
Description of the parameters
9.2.1
Time and date
Time and date (1–3)
The regulator has a year clock with setting possibilities for time, day/month
and year. Time and date must be correctly set, so that the heating
programs can operate to previously carried out programming.
Summer time (5/6)
The start of summer time can be set under prog. no. 5; the end of summer
time is set under prog. no. 6. The time changing is carried out on the
Sunday following the set date.
9.2.2
Operator section
Language (20)
This is where you can change the language of the users prompts.
Info (22)
Temporarily: The information display returns to the basic display after 8
minutes.
Permanently: The information display remains permanently displayed
after call-up with the information button.
Display of errors (23)
Program no. 23 can be used to select whether errors are displayed
showing just the error code ("Code" option) or the error code with text
("Code and text" option).
9 Settings
84
Paramount five 30 – 115
7703046 - 01 - 23072018
Содержание Paramount five 115
Страница 55: ...For more information see Technical data page 15 7 Commissioning 7703046 01 23072018 Paramount five 30 115 55 ...
Страница 138: ...For more information see Status page 132 State page 132 9 Settings 138 Paramount five 30 115 7703046 01 23072018 ...
Страница 150: ...Gas pressure not stable 11 Troubleshooting 150 Paramount five 30 115 7703046 01 23072018 ...