Configuration of extension modules
Prog. no.
Level Standard value
Contact type H2/H21 module 1
NC | NO
7322
C
NO
Input value 1 H2/H21 module 1
7324
E
0
Funct value 1 H2/H21 module 1
7325
E
0
Input value 2 H2/H21 module 1
7326
E
10
Funct value 2 H2/H21 module 1
7327
E
1000
Funct input EX21 module 1
None | Limit thermostat HC
7342
C
None
Funct output UX21 module 1
0: None | 1: Boiler pump Q1 | 2: DHW pump Q3 | 3: DHW interm circ pump Q33
| 4: Heat circuit pump HC1 Q2 | 5: Heat circuit pump HC2 Q6 | 6: Heat circuit
pump HC3 Q20| 7: Collector pump Q5 | 8: Solar pump ext exch K9 | 9: Solar
pump buffer K8 | 10: Solar pump swi pool K18
7348
E
None
Sign logic out UX21 module1
0: Standard | 1: Inverted
7349
C
Standard
Signal output UX21 module 1
0: 10 V | 1: PWM
7350
E
PWM
Funct output UX22 module 1
See
Parameters see Funct output UX21 module 1 (prog. no. 7348)!
7355
E
None
Sign logic out UX22 module1
0: Standard | 1: Inverted
7356
C
Standard
Signal output UX22 module 1
0: 10 V | 1: PWM
7357
E
PWM
Function extension module 2
See
Parameters see Function extension module 1 (prog. no.
7300).
7375
C
Heating circuit 3
Relay output QX21 module 2
See
Parameters see Relay output QX21 module 1 (prog. no.
7301)!
7376
C
None
Relay output QX22 module 2
See
Parameters see Relay output QX21 module 1 (prog. no.
7301)!
7377
C
None
Relay output QX23 module 2
See
Parameters see Relay output QX21 module 1 (prog. no.
7301)!
7378
C
None
Sensor input BX21 module 2
See
Parameters see Sensor input BX21 module 1 (prog. no. 7307)!
7382
C
None
Sensor input BX22 module 2
See
Parameters see Sensor input BX21 module 1 (prog. no. 7307)!
7383
C
None
Function input H2/H21 module 2
See
Parameters see Function input H2/H21 module 1 (prog. no.
7321)!
7396
C
Optg mode change
HCs+DHW
9 Settings
76
Paramount five 30 – 115
7703046 - 01 - 23072018
Содержание Paramount five 115
Страница 55: ...For more information see Technical data page 15 7 Commissioning 7703046 01 23072018 Paramount five 30 115 55 ...
Страница 138: ...For more information see Status page 132 State page 132 9 Settings 138 Paramount five 30 115 7703046 01 23072018 ...
Страница 150: ...Gas pressure not stable 11 Troubleshooting 150 Paramount five 30 115 7703046 01 23072018 ...