7.4.5
Gas valve
Fig.18
Gas valve
2
6
3
1
4
RA-0001307
1
2
3
4
6
x
2:
3:
1 Measuring nozzle for injector pressure
2 Setting for full load
3 Setting for low load (remove protective plug in
advance (5))
4 Measuring nozzle for connecting pressure
5 Protective plug
6 Fan pressure
x Flow direction
Setting of jet pressures:
Paramount 30 - 60: Torx T15
Paramount 80: Allen key 2,0 mm
Paramount 95 - 115: Allen key 2,5 mm
Important
The Torx-key is located in the accessory bag.
7.4.6
Manual adjustment of burner output (controller stop
function)
For controlling the CO
2
values theParamount operated in the control stop
function
7 Commissioning