6.5.5
Protection against contact
Danger of electric shock
Danger to life due by missing shock-proof protection.
To ensure shock-proof protection, all parts of the boiler to be
screwed on – the casing parts in particular – must be screwed on
correctly after work has been completed.
6.5.6
IP rating IPx4D
Tighten the cable entries to comply with the IPx4D rating and to safeguard
the specified air-tight sealing of the air chamber, so that the grommets
tighten around the cables.
6.5.7
Circulating pumps
The permissible current load per pump output is I
N max
= 1A.
6.5.8
Appliance fuses
Appliance fuse in the control unit ISR:
Mains fuses: T 6.3A H 250V
6.5.9
Connecting sensors/components
Danger
Risk of electric shock! Danger to life through incorrect work!
The wiring diagram must be followed! Optional accessories must
be fitted and connected according to the instructions provided.
Connect to the mains. Check earthing.
Outdoor temperature sensor (included in delivery)
The outdoor temperature sensor is located in the accessory bag. It should
be connected according to the wiring diagram.