PostProcess Technologies, Inc. • www.postprocess.com • REV A | page 12
1. Operation
1.3.1 Auto Setup Controls
Three settings can be configured on the
Auto Setup
screen
(Figure 6. Auto Setup Screen)
. The settings must be
properly configured based on the unique properties of the parts to be processed by the DECI and are discussed
in greater detail below.
At the upper, left are four buttons that control the
Agitation (Energy) Level
by configuring the spray nozzles
to operate in a predetermined sequence. These settings are configured by
PostProcess
personnel during the
installation process. For detailed information about configuring the settings, see the
DECI Appendix A
.
Run Time
- To set the desired run time for
the automatic cycle use the
+ / -
to adjust
the Hours (Left) and Minutes (Right).
Temperature Control
– Use the slider to set the desired
temperature of the detergent in the tank. The operator can
also use the
+ / -
to adjust the temperature.
Figure 6.
Auto Setup
Screen
Press
(4)
for
High Agitation
– bottom spray nozzles and the upper narrow-angle nozzles all
operate
for
the
highest
agitation.
Press
(3)
for
Medium Agitation
– bottom spray nozzles, one upper narrow-angle nozzles and
the upper wide angle nozzles operate for higher agitation.
Press
(2)
for
Low Agitation
– spray nozzle configuration for low level combination of bottom
nozzles and upper nozzles.
Press
(1)
for
Ultra-Low Agitation
–bottom spray nozzles only.
The selected
Agitation Level
turns
ORANGE
while non-selected levels remain
BLUE
.