Parts Lists 

The following table illustrates the component parts contained within the specific kit sets: 

Cotton Mat Kit - Product Code TBA 

Plastic Mat Kit - Product Code TBA 

SensorMATe 3 - Product Code 034-892 

SensorMATe 3 - Product Code 034-892 

Enuresis Mat Connecting Lead - Product Code 034-859 

Enuresis Mat Connecting Lead -Product Code 034-859 

Enuresis Sensor (Cotton Mat) - Product Code 1010003 

Enuresis Sensor (Plastic Mat) - Product Code 1010015 

 

Setting up Procedure 

1.

 

Locate the sensing mat in the area of the bed or chair where soiling is likely to occur. 

2.

 

Connect the two connecting lead press-studs to the sensing mat.  

3.

 

Plug the Enuresis Connecting cable into the right hand RJ22 Socket located on the top of the 
unit (See figure 2 over). 

4.

 

Insert the AA batteries (supplied) into the SensorMATe 2. Ensure correct polarity is as shown 
in the battery compartment case (See figure 3 over) 

5.

 

Switch on the SensorMATe 3 using the membrane keypad “On/Off” Switch. 

6.

 

Set the Time and date if required.  

7.

 

Press the enter key and scroll to the “System Settings” menu using the navigation keys. 

8.

 

Scroll to and select the “Set Factory Defs.” To “Yes” and press “enter”.  

9.

 

Once the unit has reset navigate to the “Enuresis Sens.” menu in the “Configure Right Input” 
menu  and adjust accordingly. Note: It is possible to adjust the sensitivity between 1 -9. 
Setting 1 being the least sensitive with respect to moisture detection. 

10.

 

Scroll to and configure the “Std. Alarm Count” as desired. If the unit is transmitting to a 
Carephone leave this set to “1”. 

11.

 

Set the “Alarm Repeat delay” (if required) 

12.

 

Set the “Upscale  Alarm” (If required) 

13.

 

Select the “Left arrow” and scroll to and enter the “Radio Settings” Page.  

14.

 

Set the “Single Receiver” mode accordingly. Note: If the unit is transmitting to a Carephone 
this should be set to “Yes”. If the unit is transmitting to a multi receiver system, it should be 
set to “No”. 

15.

 

Select the “Left arrow” and scroll down to and enter the “Test Mode” Page.  

16.

 

Use the “Up arrow” to select “Tx ID# 3”. 

17.

 

Configure the target receiver to capture the radio code then select the SensorMATe “Enter” 
key. 

18.

 

Once the code has been captured momentarily press the “standby button” to reset back to 
the home page. 

SensorMATe 3 – Enuresis solution Quick Start Guide                

(Product Codes TBA Cotton Mat and TBA Plastic Mat Kits) 

Watch the video here

 