Teleline HVI Single 5-card Shelf Cabinet, model 751960/13CU5
Table 15: Positron Shelf to Protector Block
Shelf Ring
Cable Tip
Shelf
Slot #
Cable Pair # Protector
Block
Position
Shelf Tip
Connector
Shelf Ring
Connector
1
Not Used
2
Not Used
3
Not Used
4
Not Used
BLUE/WHITE
WHITE/BLUE
5
1
5
TB1-14
TB2-14
1
Not Used
2
Not Used
3
Not Used
4
Not Used
ORANGE/WHITE WHITE/ORANGE
5
2
13
TB1-7
TB2-7
GREEN/WHITE
WHITE/GREEN
3-GND
18
TB1-2
TB1-2
Not Used
BROWN/WHITE
WHITE/BROWN
4-24 Vdc
20
TB2-1
TB2-1
Not Used
SLATE/WHITE
WHITE/SLATE
5-48 Vdc
22
TB2-2
TB2-2
Not Used
BLUE/RED
RED/BLUE
6-RUGEN
24
TB1-1
TB1-1
Not Used
Connections
3.9.6
Utilization of the NIU Shelf Positions
The four NIU shelf slots are wired to the first four shelf slots in the Teleline shelf.
Deployment of a circuit utilizing Teleline shelf slots 1 - 4 will require either an NIU
terminating unit or a cut through card. This will then provide a communication
circuit path for the circuit from the Teleline shelf to the protector block.
3.9.7
Using a Teleline Shelf Without Deploying an NIU Device
Any of the Teleline shelf slots can be used for any circuit type. However, if the
circuit does not utilize a NIU card in the NIU shelf, a cut-through card must be
utilized in the NIU shelf to provide connectivity through the NIU shelf.
Содержание Teleline 751960/13CU5
Страница 2: ......
Страница 6: ......
Страница 7: ...Chapter 1 General Information...
Страница 14: ......
Страница 15: ...Chapter 2 Overview...
Страница 17: ...17 Introduction Figure 1 HVI Pre configured Unit 751960 13CU5...
Страница 20: ......
Страница 21: ...Chapter 3 Installation...
Страница 51: ...Chapter 4 Thermal Considerations...
Страница 57: ...Appendix A Acronyms...