background image

 

  

 

BRX Power Injector Installation Guide 

32 

180-0192-001-R01 

6  Regulatory Compliance and Safety 

FCC Declaration of Conformance 

The BRX Power Injector models comply with part 15 class A of the FCC Rules. Operation is subject to 
the following two conditions (1)  This device may not cause harmful interference,  and (2)  this device 
must accept any interference received, including interference that may cause undesired operation. 

15 Class A Information 

This  equipment  has  been  tested  and  found  to  comply  with  the  limits  for  a  Class  A  digital  device, 
pursuant  to  Part  15  of  the  FCC  rules.  These  limits  are  designed  to  provide  reasonable  protection 
against  harmful  interference  when  the  equipment  is  operated  in  a  commercial  environment.    This 
equipment generates; uses and can radiate radio frequency energy and, if not installed and used in 
accordance  with  the  instruction  manual,  may  cause  harmful  interference  to  radio  communications.  
Operation of this equipment in a residential area is likely to cause harmful interference in which case 
the user will be required to correct the interference at his own expense. 

Industry Canada 

The  BRX  Power  Injector  models  comply  with  ICES-003  of  the  Industry  Canada  Rules.  Operation  is 
subject  to  the  following  two  conditions:  (1)  This  device  may  not  cause  harmful  interference,  and  (2) 
this  device  must  accept  any  interference  received,  including  interference  that  may  cause  undesired 
operation. 

Les  produits  BRX  Power  Injector  sont  conformes  à  la  norme  NMB-003  d'Industrie  Canada.  Leur 
fonctionnement  est  sujet  aux  deux  conditions  suivantes:  (1)  le  dispositif  ne  doit  pas  produire  de 
brouillage préjudiciable, et (2) ce dispositif doit accepter tout brouillage reçu, y compris un brouillage 
susceptible de provoquer un fonctionnement indésirable. 

Europe - EU Declaration of Conformity 

The  BRX  Power  Injector  models  comply  with  the  essential  requirements  of  the  EMC  Directive 
2014/30/EU and Low Voltage Directive 2014/35/EU. The following test methods have been applied in 
order  to  prove  presumption  of  conformity  with  the  essential  requirements  of  the  EMC  Directive 
2014/30/EU and Low Voltage Directive 2014/35/EU: 

CSA  C22.2#60950-1:  Issued:  2007/03/27  Ed:  2  (R2012)  Information  Technology  Equipment  Safety 
Part 1: General Requirements; Amendment 1: 2011, Amendment 2: 2014 
UL  60950-1:  Issued:  2007/03/27  Ed:  2  Rev:  2014/10/14  Information  Technology  Equipment  Safety 
Part 1: General Requirements 
IEC  60950-1:  Issued:  2013/05/28  Ed:  2.2  Information  Technology  Equipment  -  Safety  -  Part  1: 
General Requirements; Consolidated Edition. Ed. 2: 2005 
IEC  60950-22  Issued:  2005/10/20  Ed:  1  Information  Technology  Equipment  -Safety  -Part  22: 
Equipment to be Installed Outdoors 
CSA  22.2  No.  60950-22-07  (R2016)  Issued:  2007/04/23  Ed:  1  Information  Technology  Equipment  -
Safety -Part 22: Equipment to be Installed Outdoors (Bi-National standard, with UL 60950-22) 
UL  60950-22  Issued:  2007/04/23  Ed:  1  Information  Technology  Equipment  -Safety  -Part  22: 
Equipment to be Installed Outdoors 

Содержание BRX

Страница 1: ...BRX Power Injector Installation Guide 180 0192 001 R01 Broadband Reach eXtender Power Injector BRX PWR Installation Guide Document 180 0192 001 March 2020...

Страница 2: ...By Positron Access Solutions Corporation 5101 Buchan Street Suite 220 Montreal Quebec Canada H4P 2R9 Telephone US and Canada 1 888 577 5254 International 1 514 345 2220 Product names other than Posit...

Страница 3: ...Local 110 220Vac Source 11 3 1 3 Express RFT V Power Pairs 15 3 2 Grounding the BRX Power Injector 16 3 3 Using Bypass Section for POTS pairs 17 3 4 Installing Copper Cables into BRX Power Injector 1...

Страница 4: ...AM POTS SPLITTER 31 FIGURE 10 CONNECTING THE BRX POWER INJECTOR TO A HUAWEI MA5116S SERIES DSLAM 31 List of Tables TABLE 1 BRX POWER INJECTOR POWERING OPTIONS AND ORDERING CODES 9 TABLE 2 CONNECTING A...

Страница 5: ...power the BRX devices installed on xDSL pairs requiring amplification The BRX Power Injector installs adjacent to the DSLAM where its power pairs connect to the POTS port of the DSLAM where the CO tel...

Страница 6: ...s Power to the BRX and Error Condition if any The following block diagram figure 2 highlights the inside of the BRX Power Injector Figure 2 Inside the BRX Power Injector The power source of the BRX Po...

Страница 7: ...connection to the DSLAM It is also possible to use the BRX Power Injector as a basic cross connect when having to combine POTS and BRX Power pairs on the same cable binder s and in the absence of a c...

Страница 8: ...ia punch down blocks POTS pairs in input to the BRX Power Injector shall be punched into the bypass section The output blocks of the bypass section allow you to mix POTS and BRX Power pairs into their...

Страница 9: ...with local 48Vdc input BRX PWR 24 24 pair BRX Power Injector with local 48Vdc input Local 110 220Vac BRX PWR 8 AC 8 pair BRX Power Injector with local 110 220Vac input BRX PWR 16 AC 16 pair BRX Power...

Страница 10: ...ne or two DC Power cable Be careful when cutting an opening in the rubber grommet since you will need to apply a silicon sealant in step 2 NOTE you can refer to steps 7 to 12 for the installation of t...

Страница 11: ...ower source Figure 6 AC cable pre installed and terminated in the BRX Power Injector Here is the procedure to follow should you need to install a longer AC power cord Step 1 You will need a set of pli...

Страница 12: ...st to secure the AC Power Cable in the BRX Power Injector enclosure Step 4 secure the ground wire green to the pre installed grounding lug of the BRX Power Injector enclosure Do not over tighten Step...

Страница 13: ...er grommet from the enclosure of the BRX Power Injector You will need to lift the light grey sealant of the enclosure to loosen the rubber grommet Step 8 using a sharp box cutter or similar tool follo...

Страница 14: ...rough the opening Step 10 re insert the rubber grommet back into its original position Step 11 re install the grey sealant gasket back into place to ensure the IP65 rating of the enclosure of the BRX...

Страница 15: ...leftmost opening slice open the rubber grommet and insert the binder cable with the dedicated RFT V Express Power Pairs 190Vdc IMPORTANT NOTE make sure the pairs are unpowered before manipulating the...

Страница 16: ...ounding lug to the ground wire You should use wire gauge of at least 10 AWG and up to 6 AWG Step 2 Use the lock washer and nut pre installed on the grounding post of the BRX Power Injector Step 3 inse...

Страница 17: ...ort s of the DSLAM Step 1 insert the cable binders with the POTS pairs into the second from the left connector As per the installation of the AC Power Cable remove the rubber grommet and cut an openin...

Страница 18: ...to connect the pairs of each cable binder that require the 48Vdc power to feed BRX devices on otherwise dry pairs You are now ready to connect the binder cables of the rightmost opening to the nearby...

Страница 19: ...ng the Rubber Grommets before Installation Once you have mounted the BRX Power Injector in its final location you will need to apply a silicon sealant to ensure the IP65 rating of the enclosure We rec...

Страница 20: ...on Sealant to the rubber grommets in use 3 6 Installing additional BRX PWR M Module s When initially installing an 8 pair or 16 pair version of the BRX Power Injector it is possible to install one or...

Страница 21: ...nting screws Step 3 when installing the BRX PWR M module make sure you align the connector on the bottom surface of the BRX PWR M with the connectors on the motherboard of the BRX Power Injector Step...

Страница 22: ...making good contact with the matching connectors on the motherboard Step 6 use the four 4 mounting screws to secure the BRX PWR M to the motherboard Step 7 the newly installed BRX PWR M is now ready...

Страница 23: ...se 4 1 LED Descriptions The BRX Power Injector incorporates status LEDs to confirm its proper operation and report any problems with the loops Table 10 Power LED Table 11 BRX Power Pair Status LED PAI...

Страница 24: ...at the red return wire connects to the 48VRTNA for the first DC Power Cable For the optional second DC Power cable make sure that the black live 48Vdc wire connects to the 48VB and that the red return...

Страница 25: ...electrician Case 4 Express Power Pairs 190Vdc Make sure that the Power Status LEDs at the top end of the factory installed GE or ALPHA down converter module is ON If it is OFF you should inspect fuse...

Страница 26: ...r cabling to the BRX Power Injector is properly installed and that the local 48Vdc or 112 220VAc power source is activated If using RFT V make sure there is current on the Express Power pairs SYMPTOM...

Страница 27: ...f a BRX Power Pair is RED Case 1 pair has a shorted path between TIP and RING Make sure the pair is properly inserted in the punch down block You should also verify the pairs are properly connected to...

Страница 28: ...no longer has a Dial Tone Make sure that the POTS pair from the Voice Switch CO is properly inserted in the Punch down Block connector in the BYPASS IN left section You should then make sure the POTS...

Страница 29: ...rate the POTS dial tone and the 48Vdc sealing current internally and do not require a BRX Power Injector 5 1 Adtran 1148V The Adtran 1148 family uses a pair of Amphenol connectors to connect to the te...

Страница 30: ...48Vdc current to flow through the DSLAM it is important to insert a 5 pin Gas Tube Discharge device Bourns or similar in the corresponding socket for each pair requiring BRX amplification Figure 8 Co...

Страница 31: ...one on each pair along with the 48Vdc sealing current The POTS Splitter integrated in the Huawei MA 5116S series DSLAM will merge the 48Vdc from the POTS pairs with the DSL signal from the DSLAM onto...

Страница 32: ...ference that may cause undesired operation Les produits BRX Power Injector sont conformes la norme NMB 003 d Industrie Canada Leur fonctionnement est sujet aux deux conditions suivantes 1 le dispositi...

Страница 33: ...BRX PWR 24 AC BRX PWR 8 A BRX PWR 16 A BRX PWR 24 A BRX PWR 8 G BRX PWR 16 G and BRX PWR 24 G Les mod les BRX Power Injector suivants sont conformes aux normes IEC 60950 1 UL 60950 1 CAN C22 2 60950 1...

Страница 34: ...anty information can be found in your Positron Access customer web portal http www positronaccess com Portal php Positron Access Solutions Sales Pricing Availability and Technical Support US and Canad...

Отзывы: