AK355 System

 

Installation and User's Guide

 

 
 

  
 
 
 
 
 
 
 

Содержание AK355

Страница 1: ...AK355 System Installation and User s Guide...

Страница 2: ...es with part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 this device must accept any interference received including...

Страница 3: ...3 4 System 21 2 3 5 Inventory 22 2 3 6 Provisioning 24 2 3 7 Alarms 55 2 3 8 Performance Monitoring PM 59 2 3 9 Tools 76 2 3 10 Diagnostic 79 2 3 11 License 83 Chapter 3 85 AktinoView Management Soft...

Страница 4: ...ions 4 180 0037 002 R01 Chapter 5 153 Maintenance 153 5 1 AK355 Fans and Filters 154 Chapter 6 155 Safety and Warnings 155 Chapter 7 159 Warranty and Customer Service 159 Chapter 8 161 Positron Produc...

Страница 5: ...AK355 System Installation and User s Guide Positron Access Solutions 5 180 0037 002 R01 Chapter 1 ______________________________________ AK355 System...

Страница 6: ...ic or asymmetric high bandwidth link capable of delivering up to 100 Mbps out to 12 Kft 3 7 Km 24 AWG or 45 Mbps out to 17 Kft 5 2 Km 24 AWG Positron s signature FlexStream functionality enables the A...

Страница 7: ...ovided for flush or mid mount Note that the mid mount flange can be mounted forward or backward for either 5 or 6 inch recess Figure 1 shows examples of 19 inch flanges attached to the flush position...

Страница 8: ...nstallation and User s Guide Positron Access Solutions 8 180 0037 002 R01 Figure 2 Wall Mounting NOTE The fan filter should be replaced every six months Ordering information can be found at the end of...

Страница 9: ...gement Connections The RJ 45 port located on the front panel can be used for local or remote management access The Ethernet port automatically is set to either 10BaseT or 100BaseT and auto sense the p...

Страница 10: ...Alarm PAIR STATUS Off Solid Green Flashing Green Solid Red Pair Is Disabled Pair Is Up Pair Is Acquiring Pair LOS Open Circuit Short BAT A BAT B Off Solid Green External DC Power Has Not Been Applied...

Страница 11: ...of the back panel see Figure 4 can accommodate up to 6 AWG wire Use a wire gauge for grounding at least as heavy as the power wiring Attach the grounding wire to the AK355 Ground Lug to a nearby groun...

Страница 12: ...A and B The two power inputs are identical and can be used for redundant power configurations Insert the ends of the 48 Vdc and Return power wires 16 AWG wire is recommended into the A and B holes on...

Страница 13: ...2 27 2 Pair 3 28 3 Pair 4 29 4 Pair 5 30 5 Pair 6 31 6 Pair 7 32 7 Pair 8 33 8 Pair 9 34 9 Pair 10 35 10 Pair 11 36 11 Pair 12 37 12 Pair 13 38 13 Pair 14 39 14 Pair 15 40 15 Pair 16 41 16 The CO MSPA...

Страница 14: ...onnection SysID connections can be used to identify the equipment in alarm SysID is active during any alarm activation Aux1 and Aux2 are input alarm dry contact delay point The Alarm CutOff ACO connec...

Страница 15: ...AK355 System Installation and User s Guide Positron Access Solutions 15 180 0037 002 R01 Chapter 2 ______________________________________ AktinoView Management Software Ethernet Mode...

Страница 16: ...oView from Positron s portal located at http www positronaccess com Open Windows Explorer and click on the CD drive Double click on install exe in the AktinoView folder Follow the instructions on the...

Страница 17: ...will result with the RT rebooting 4 Right click on the CO once the RT disappears 5 Select Switch to Ethernet Mode from the CO drop down box and then select OK This will initiate a process that will re...

Страница 18: ...to your PC so that you may retrieve and restore the configuration at a later date System Restore Opens a dialog box to import and apply a previously saved System Configuration file The process of res...

Страница 19: ...system it will display several additional tabs appropriate for the selected system In this case AktinoView displays the following tabs for the system in Ethernet mode System Inventory Provisioning Al...

Страница 20: ...0037 002 R01 Alarm Details AktinoView displays detailed alarm information for each system It displays counters for the active Critical Major and Minor alarms as well as detailed alarm information for...

Страница 21: ...AK355 System Installation and User s Guide Positron Access Solutions 21 180 0037 002 R01 2 3 4 System The System tab provides a front panel representation of the system...

Страница 22: ...AK355 System Installation and User s Guide Positron Access Solutions 22 180 0037 002 R01 2 3 5 Inventory The Inventory tab provides details for the CO and RT Units comprising the system...

Страница 23: ...feature options See the following table for Parameters and Values Parameter Values Slot Slot number Unit Location Description Detailed description Serial Serial Number CLEI Code Telcordia assigned CL...

Страница 24: ...ning Clicking the Provisioning tab displays all the provisioning sub sections supported by the system 2 3 6 1 Equipment Selecting the Equipment tab under Provisioning allows equipment provisioning of...

Страница 25: ...AK355 System Installation and User s Guide Positron Access Solutions 25 180 0037 002 R01...

Страница 26: ...AK355 System Installation and User s Guide Positron Access Solutions 26 180 0037 002 R01...

Страница 27: ...Disable local management accessfor CRU Repeater Type For Regenerator Applications Other Span IP Address For Regenerator Applications indicate the Other Span IP Address Do not use the same IP Address a...

Страница 28: ...AK355 System Installation and User s Guide Positron Access Solutions 28 180 0037 002 R01 2 3 6 2 Ethernet Selecting the Ethernet tab under Provisioning allows Ethernet provisioning of the system...

Страница 29: ...AK355 System Installation and User s Guide Positron Access Solutions 29 180 0037 002 R01 Double click on an Ethernet Port to bring up an Ethernet provisioning dialog box...

Страница 30: ...for the Ethernet data where 0 means no Ingress Rate Limit is set VLAN Trust Mode For CRUs in TunneledVLAN mode only YES RT Ingress packets which have a VLAN ID matching a provisioned VLAN ID will be...

Страница 31: ...r s Guide Positron Access Solutions 31 180 0037 002 R01 2 3 6 3 SNMP Selecting the SNMP tab allows setting SNMP receiver parameters Double clicking on the Index brings up the SNMP Trap Receivers dialo...

Страница 32: ...AK355 System Installation and User s Guide Positron Access Solutions 32 180 0037 002 R01...

Страница 33: ...urable string of up to 20 characters Contact User configurable string of up to 64 characters Location User configurable string of up to 64 characters Read Community String The SNMP Read Community Stri...

Страница 34: ...ns 34 180 0037 002 R01 2 3 6 4 MSPAN Selecting the MSPAN tab under Provisioning allows MSPAN provisioning of the system Note Configuring Line Powering on an AK355RP is done by connecting to the Aktino...

Страница 35: ...e Positron Access Solutions 35 180 0037 002 R01 Double clicking on the Slot number entry in either the General Parameters area or the Advanced Parameters area provides the MSPAN Parameters dialog box...

Страница 36: ...the MSPAN Rate in Symmetric Mode Rate Upstream Sets the Upstream MSPAN Rate in Asymmetric Mode Rate Downstream Sets the Downstream MSPAN Rate in Asymmetric Mode Line Powering Sets Line Powering to Of...

Страница 37: ...20 32msec Latency Downstream Sets the Downstream Latency 0 1 2 4 8 12 16 20 32msec Impulse Protection Upstream Length of Upstream Impulse Noise Protection 50 125 250 500 750 1000 2000 4000 sec Impulse...

Страница 38: ...AK355 System Installation and User s Guide Positron Access Solutions 38 180 0037 002 R01 2 3 6 5 Pair Selecting the Pair tab under the Provisioning tab allows Pair provisioning of the system...

Страница 39: ...licking on the Pair brings up the following Pair provisioning dialog box See the following table for Pair Provisioning Parameters and Values Pair Parameters Values Circuit ID User configurable string...

Страница 40: ...allation and User s Guide Positron Access Solutions 40 180 0037 002 R01 2 3 6 6 Ethernet Services 2 3 6 6 1Type of Service Selecting the Ethernet Type of Services tab allows type of service provisioni...

Страница 41: ...AK355 System Installation and User s Guide Positron Access Solutions 41 180 0037 002 R01 Double clicking on a slot brings up the following Ethernet Service provisioning dialog box...

Страница 42: ...Pause frames are not sent forflow control Lossless Pause frames are used as the flow control mechanism The Port VLAN and DiffServ priorities are also active RT QoS Mode QoS Port VLAN and DiffServ prio...

Страница 43: ...em Installation and User s Guide Positron Access Solutions 43 180 0037 002 R01 2 3 6 6 2 Quality of Service Selecting the Quality of Service tab unit allows Global Quality of Service provisioning of t...

Страница 44: ...and User s Guide Positron Access Solutions 44 180 0037 002 R01 Double clicking on any area in the VLAN Priority or IP Differential Service Priority brings up the following Ethernet Quality of Service...

Страница 45: ...e MAC Address table Service Ether Type Value for Ether Type Field thatis used when adding a service VLAN tag VLAN Priority Allows for the mapping of priority levels for each of the AK355 System s eigh...

Страница 46: ...User s Guide Positron Access Solutions 46 180 0037 002 R01 2 3 6 6 3 VLAN Selecting the VLAN tab allows the VLAN provisioning of the system Note that this menu is available when the System is provisio...

Страница 47: ...eate VLAN dialog box See the following table for the VLAN Parameters and Values VLAN Parameters Values VLAN ID Enter a VLAN ID from 1 to 4092 VLAN Name User configurable string of up to 31 characters...

Страница 48: ...ss Solutions 48 180 0037 002 R01 2 3 6 6 4 VLAN Administration Selecting the VLAN Administration tab allows you to provision a management VLAN The VLAN can be transparently passed through to RT ports...

Страница 49: ...tion Parameters and Values VLAN Administration Parameters Values VLAN ID Enter a VLAN ID from 1 to 4092 a value of 0 disables the Management VLAN IP Address The IP Address for the Management VLAN Subn...

Страница 50: ...User s Guide Positron Access Solutions 50 180 0037 002 R01 2 3 6 7 Craft Access Selecting the Craft Access tab under Provisioning allows management administration Click on Create to display the follo...

Страница 51: ...AK355 System Installation and User s Guide Positron Access Solutions 51 180 0037 002 R01...

Страница 52: ...tallation and User s Guide Positron Access Solutions 52 180 0037 002 R01 2 3 6 8 IP Route The IP Route tab allows you to provision static routes for the CO unit Click the Create button to display the...

Страница 53: ...AK355 System Installation and User s Guide Positron Access Solutions 53 180 0037 002 R01...

Страница 54: ...itron Access Solutions 54 180 0037 002 R01 See the following table for the IP Route Parameters and Values IP Route Parameters Values Network Destination Destination Network Address Network Mask Networ...

Страница 55: ...de Positron Access Solutions 55 180 0037 002 R01 2 3 7 Alarms 2 3 7 1 CO Alarm Log The CO Alarm Log tab displays a list of all the alarms observed on the AK355C including time stamp information as to...

Страница 56: ...Solutions 56 180 0037 002 R01 2 3 7 2 CO Alarm History The CO Alarm History tab displays the alarms that have been observed by the CO unit and how many times each of the alarms has been observed as we...

Страница 57: ...s Guide Positron Access Solutions 57 180 0037 002 R01 2 3 7 3 RT Alarm Log The RT Alarm Log tab displays a list of all the alarms observed on the RT unit including time stamp information as to when t...

Страница 58: ...Solutions 58 180 0037 002 R01 2 3 7 4 RT Alarm History The RT Alarm History tab displays the alarms that have been observed by the RT unit and how many times each of the alarms has been observed as we...

Страница 59: ...formation for the system s Ethernet Ports MSPAN interfaces and individual MSPAN Pairs This PM data is provided for both the CO and RT sides of the system 2 3 8 1 CO Ethernet Summary The Summary tab di...

Страница 60: ...ccess Solutions 60 180 0037 002 R01 2 3 8 2 CO Ethernet Detail The Detail tab displays detailed Ethernet counters for the Ethernet Ports The page can be provisioned to refresh automatically and time s...

Страница 61: ...tions 61 180 0037 002 R01 2 3 8 3 CO Ethernet MAC Addresses The MAC Addresses tab displays the Ethernet MAC Addresses learned by the selected port The page can be provisioned to refresh automatically...

Страница 62: ...e sections 1 The heading section provides summary information for the MSPAN including upstream MSPAN Capacity Rate and SNR Margin values 2 The 15 Minutes section provides PM data for 15 Minute interva...

Страница 63: ...s 63 180 0037 002 R01 2 3 8 5 CO Pair Summary The Summary tab displays the upstream Pair Summary information for all the Pairs supported by the MSPAN The page can be provisioned to refresh automatical...

Страница 64: ...002 R01 2 3 8 6 CO Pair Current 15 Minutes The 15 Minutes tab displays the upstream Pair PM information for all the Pairs supported by the MSPAN for the last 15 minute interval The page can be provisi...

Страница 65: ...2 R01 2 3 8 7 CO Pair Current 24 Hours The Current 24 Hours tab displays the upstream Pair PM information for all the Pairs supported by the MSPAN for the current day The page can be provisioned to re...

Страница 66: ...the PM can be displayed for each of the Pairs of the MSPAN 1 The heading section provides summary information for the MSPAN including upstream Pair Capacity Rate and SNR Margin values 2 The 15 Minutes...

Страница 67: ...olutions 67 180 0037 002 R01 2 3 8 9 RT Ethernet Summary The Summary tab displays Ethernet Link information and counters for the Ethernet Ports The page can be provisioned to refresh automatically and...

Страница 68: ...cess Solutions 68 180 0037 002 R01 2 3 8 10 RT Ethernet Detail The Detail tab displays detailed Ethernet counters for the Ethernet Ports The page can be provisioned to refresh automatically and time s...

Страница 69: ...K355 System Installation and User s Guide Positron Access Solutions 69 180 0037 002 R01 2 3 8 11 RT Ethernet Circuit The Circuit tab shows performance monitoring traffic from the RT Port to the CO Por...

Страница 70: ...ions 70 180 0037 002 R01 2 3 8 12 RT Ethernet MAC Addresses The MAC Addresses tab displays the Ethernet MAC Addresses learned by the selected port The page can be provisioned to refresh automatically...

Страница 71: ...ree sections 1 The heading section provides summary information for the MSPAN including upstream MSPAN Capacity Rate and SNR Margin values 2 The 15 Minutes section provides PM data for 15 Minute inter...

Страница 72: ...0037 002 R01 2 3 8 14 RT Pair Summary The RT side Pair Summary tab displays the downstream Pair Summary information for all the Pairs supported by the MSPAN The page can be provisioned to refresh aut...

Страница 73: ...1 2 3 8 15 RT Pair Current 15 Minutes The Current 15 Minutes tab displays the downstream Pair PM information for all the Pairs supported by the MSPAN for the last 15 minute interval The page can be pr...

Страница 74: ...R01 2 3 8 16 RT Pair Current 24 Hours The Current 24 Hours tab displays the downstream Pair PM information for all the Pairs supported by the MSPAN for the current day The page can be provisioned to r...

Страница 75: ...d the PM can be displayed for each of the Pairs of the MSPAN 1 The heading section provides summary information for the MSPAN including upstream Pair Capacity Rate and SNR Margin values 2 The 15 Minut...

Страница 76: ...ch component of the system The Active partition contains the firmware version currently running The Standby partition is used for firmware upgrades and provides a means of having a backup firmware ver...

Страница 77: ...Log Resets only the Alarm Logs in the CO unit Reset to Factory Defaults Resets the CO to factory defaults Switch to Ethernet Mode DS3 Mode for Systems supporting DS3 Switches the CO to the desired mo...

Страница 78: ...esets only the Performance Monitoring data in the RT Reset Logs Resets only the Alarm Logs in the RT Reset PM Logs Resets only the Alarm Logs in the RT Reset to Factory Defaults Resets the RT to facto...

Страница 79: ...get distance from the chassis remove the MSPAN connector from the chassis If removal of the MSPAN connector is not possible calibration can be done at any point in the loop including the MDF This poi...

Страница 80: ...iagnostic If there are large differences in the line length of the pairs it indicates possibly a short open ground fault or bridge tap If the pair is open in the middles of a loop the length will indi...

Страница 81: ...test The Status of the DELT test is indicated to run the test 3 The results can be exported to an Excel csv file by clicking on the Export Test Result button The results of the DELT test are indicate...

Страница 82: ...180 0037 002 R01 numbers should be close in value Large differences in the current flow values indicate a problem with that pair No current should be flowing between pairs If there is current flowing...

Страница 83: ...Solutions 83 180 0037 002 R01 2 3 11 License The License tab displays the features that are activated for the AK355 System Click on the CO unit to bring up the Software License dialog box Contact cust...

Страница 84: ...See the following table for the Features and Values Feature Values Asymmetric 2 2 Mhz Line Powering Activated Thisfeature is activated on the selected slot Not Activated This feature is not activated...

Страница 85: ...AK355 System Installation and User s Guide Positron Access Solutions 85 180 0037 002 R01 Chapter 3 ______________________________________ AktinoView Management Software DS3 Mode...

Страница 86: ...w from Positron s portal located at http www positronaccess com Open Windows Explorer and click on the CD drive Double click on install exe in the AktinoView folder Follow the instructions on the scre...

Страница 87: ...sult with the RT rebooting 4 Right click on the CO Unit once the RT Unit disappears 5 Select Switch to DS3 Mode from the CO drop down box and then select OK This will initiate a process that will resu...

Страница 88: ...to your PC so that you may retrieve and restore the configuration at a later date System Restore Opens a dialog box to import and apply a previously saved System Configuration file The process of res...

Страница 89: ...given system it will display several additional tabs appropriate for the selected system In this case AktinoView displays the following tabs for an AK355 System System Inventory Provisioning Alarms P...

Страница 90: ...0037 002 R01 Alarm Details AktinoView displays detailed alarm information for each system It displays counters for the active Critical Major and Minor alarms as well as detailed alarm information for...

Страница 91: ...AK355 System Installation and User s Guide Positron Access Solutions 91 180 0037 002 R01 3 3 4 System The System tab provides a front panel representation of the AK355 System...

Страница 92: ...AK355 System Installation and User s Guide Positron Access Solutions 92 180 0037 002 R01 3 3 5 Inventory The Inventory tab provides details for the AK355C and the AK355R comprising the AK355 System...

Страница 93: ...ee the following table for Parameters and Values Parameter Values Slot Slot number Unit Location Description Detailed description Serial Serial Number CLEI Code Telcordia assigned CLEI code MAC Addres...

Страница 94: ...g Clicking the Provisioning tab displays all the provisioning sub sections supported by the AK355 System 3 3 6 1 Equipment Selecting the Equipment tab under Provisioning allows equipment provisioning...

Страница 95: ...AK355 System Installation and User s Guide Positron Access Solutions 95 180 0037 002 R01...

Страница 96: ...AK355 System Installation and User s Guide Positron Access Solutions 96 180 0037 002 R01...

Страница 97: ...Disable local management accessfor CRU Repeater Type For Regenerator Applications Other Span IP Address For Regenerator Applications indicate the Other Span IP Address Do not use the same IP Address a...

Страница 98: ...tab under CO unit allows DS3 provisioning of the system Double click on the CO or the RT to bring up the provisioning dialog box for the selected unit Note that some of the parameters changed on the C...

Страница 99: ...AK355 System Installation and User s Guide Positron Access Solutions 99 180 0037 002 R01 The following is the DS3 CO unit provisioning dialog box...

Страница 100: ...AK355 System Installation and User s Guide Positron Access Solutions 100 180 0037 002 R01 The following is the DS3 RT unit provisioning dialog box See the following table for parameters and values...

Страница 101: ...yload Type Channelized DS3 TDM ATM Scrambled ATM Clear Channel Loopback Timeout 0 20 60 3600 24 hours minutes FEAC Pass Through YES DS3 FEAC loopback messages from the network are reacted upon by the...

Страница 102: ...Selecting the DS1 tab under the CO unit allows DS3 tributary provisioning of the system Double click on the Index to bring up the DS1 provisioning dialog box Note that this screen is only active if D...

Страница 103: ...rs and values DS1 Provisioning Parameters and Values Parameter Values Circuit ID Circuit ID of DS1 up to 48 characters Priority 0 Low through 7 High When system needs to downshift the MSPAN rate durin...

Страница 104: ...002 R01 3 3 6 4 ATM Inband Selecting the ATM Inband tab under Provisioning allows ATM Inband Management provisioning of the system The DS3 Payload Type must be in an ATM mode to allow provisioning th...

Страница 105: ...rs and values ATM Inband Parameters and Values Parameters Values VPI Virtual Path Identifier VCI Virtual Circuit Identifier IP Address IP Address of the Positron unit must be in a different subnet vs...

Страница 106: ...180 0037 002 R01 3 3 6 5 AUX Alarms Selecting the AUX Alarms tab under Provisioning allows external alarm provisioning of the system These parameters determine how the AUX1 and AUX2 input pins on the...

Страница 107: ...ovisioning dialog See the following table for Parameters and Values AUX Alarm Parameters and Values Parameters Values Alarm Type This value is reported as alarm type in the TL 1 alarm message up to 16...

Страница 108: ...r s Guide Positron Access Solutions 108 180 0037 002 R01 3 3 6 6 SNMP Selecting the SNMP tab allows setting SNMP receiver parameters Double clicking on the Index brings up the SNMP Trap Receivers dial...

Страница 109: ...AK355 System Installation and User s Guide Positron Access Solutions 109 180 0037 002 R01...

Страница 110: ...gurable string of up to 20 characters Contact User configurable string of up to 64 characters Location User configurable string of up to 64 characters Read Community String The SNMP Read Community Str...

Страница 111: ...ns 111 180 0037 002 R01 3 3 6 7 MSPAN Selecting the MSPAN tab under Provisioning allows MSPAN provisioning of the system Note Configuring Line Powering on an AK355RP is done by connecting to the Aktin...

Страница 112: ...Guide Positron Access Solutions 112 180 0037 002 R01 Double clicking on a Slot entry in either the General Parameters area or the Advanced Parameters area provides the MSPAN Parameters dialog box for...

Страница 113: ...the MSPAN Rate in Symmetric Mode Rate Upstream Sets the Upstream MSPAN Rate in Asymmetric Mode Rate Downstream Sets the Downstream MSPAN Rate in Asymmetric Mode Line Powering Sets Line Powering to Of...

Страница 114: ...20 32msec Latency Downstream Sets the Downstream Latency 0 1 2 4 8 12 16 20 32msec Impulse Protection Upstream Length of Upstream Impulse Noise Protection 50 125 250 500 750 1000 2000 4000 sec Impulse...

Страница 115: ...AK355 System Installation and User s Guide Positron Access Solutions 115 180 0037 002 R01 3 3 6 8 Pair Selecting the Pair tab under the Provisioning tab allows Pair provisioning of the system...

Страница 116: ...clicking on the Pair entry to bring up the Pair provisioning dialog box See the following table for Pair Provisioning Parameters and Values Pair Parameters Values Circuit ID User configurable string o...

Страница 117: ...3 3 6 9 DS3 Loopback Selecting the DS3 Loopback tab under Provisioning allows you to enable DS3 loopbacks on either the CO or RT unit Right click on the Unit to select the type of DS3 Loopback desire...

Страница 118: ...AK355 System Installation and User s Guide Positron Access Solutions 118 180 0037 002 R01 The following screen shot from the System tab reveals a loopback set Toward Network...

Страница 119: ...r s Guide Positron Access Solutions 119 180 0037 002 R01 3 3 6 10 Craft Access Selecting the Craft Access tab under Provisioning allows User Management Administration Click on Create to bring up the f...

Страница 120: ...AK355 System Installation and User s Guide Positron Access Solutions 120 180 0037 002 R01...

Страница 121: ...lation and User s Guide Positron Access Solutions 121 180 0037 002 R01 3 3 6 11 IP Route The IP Route tab allows you to provision static routes for the AK355C Click the Create button to display the fo...

Страница 122: ...itron Access Solutions 122 180 0037 002 R01 See the following table for the IP Route Parameters and Values IP Route Parameters Values Network Destination Destination Network Address Network Mask Netwo...

Страница 123: ...de Positron Access Solutions 123 180 0037 002 R01 3 3 7 Alarms 3 3 7 1 CO Alarm Log The CO Alarm Log tab displays a list of all the alarms observed on the AK355C including time stamp information as to...

Страница 124: ...Solutions 124 180 0037 002 R01 3 3 7 2 CO Alarm History The CO Alarm History tab displays the alarms that have been observed by the AK355C and how many times each of the alarms has been observed as we...

Страница 125: ...s Guide Positron Access Solutions 125 180 0037 002 R01 3 3 7 3 RT Alarm Log The RT Alarm Log tab displays a list of all the alarms observed on the AK355R including time stamp information as to when t...

Страница 126: ...s Solutions 126 180 0037 002 R01 3 3 7 4 Alarm History The RT Alarm History tab displays the alarms that have been observed by the AK355R and how many times each of the alarms has been observed as wel...

Страница 127: ...mation for the AK355 System s Ethernet Ports MSPAN interfaces and individual MSPAN Pairs This PM data is provided for both the CO and RT sides of the system 3 3 8 1 CO DS3 DS3 performance monitoring s...

Страница 128: ...owing out of either CO or RT Positron DS3 port ATM modes only CVL Line Code Violations ESL Line Errored Seconds SESL Line Severly Errored Seconds LOSSL Line Loss of Signal Seconds CVP Path Code Violat...

Страница 129: ...ee sections 1 The heading section provides summary information for the MSPAN including upstream MSPAN Capacity Rate and SNR Margin values 2 The 15 Minutes section provides PM data for 15 Minute interv...

Страница 130: ...s 130 180 0037 002 R01 3 3 8 3 CO Pair Summary The Summary tab displays the upstream Pair Summary information for all the Pairs supported by the MSPAN The page can be provisioned to refresh automatica...

Страница 131: ...002 R01 3 3 8 4 CO Pair Current 15 Minutes The 15 Minutes tab displays the upstream Pair PM information for all the Pairs supported by the MSPAN for the last 15 minute interval The page can be provisi...

Страница 132: ...2 R01 3 3 8 5 CO Pair Current 24 Hours The Current 24 Hours tab displays the upstream Pair PM information for all the Pairs supported by the MSPAN for the current day The page can be provisioned to re...

Страница 133: ...the PM can be displayed for each of the Pairs of the MSPAN 1 The heading section provides summary information for the MSPAN including upstream Pair Capacity Rate and SNR Margin values 2 The 15 Minute...

Страница 134: ...utions 134 180 0037 002 R01 3 3 8 7 RT DS3 DS3 performance monitoring shows the errors coming INTO the RT unit Ninety six fifteen minute time period bins and seven 24 hour time period bins display the...

Страница 135: ...ee sections 1 The heading section provides summary information for the MSPAN including upstream MSPAN Capacity Rate and SNR Margin values 2 The 15 Minutes section provides PM data for 15 Minute interv...

Страница 136: ...80 0037 002 R01 3 3 8 9 RT Pair Summary The RT side Pair Summary tab displays the upstream Pair Summary information for all the Pairs supported by the MSPAN The page can be provisioned to refresh auto...

Страница 137: ...R01 3 3 8 10 RT Pair Current 15 Minutes The Current 15 Minutes tab displays the upstream Pair PM information for all the Pairs supported by the MSPAN for the last 15 minute interval The page can be pr...

Страница 138: ...2 R01 3 3 8 11 RT Pair Current 24 Hours The Current 24 Hours tab displays the upstream Pair PM information for all the Pairs supported by the MSPAN for the current day The page can be provisioned to r...

Страница 139: ...the PM can be displayed for each of the Pairs of the MSPAN 1 The heading section provides summary information for the MSPAN including upstream Pair Capacity Rate and SNR Margin values 2 The 15 Minute...

Страница 140: ...tandby Firmware versions for each components of the AK355 System Right Clicking on an AK355C allows you to select the following system management options Software Upgrade CO Only Upgrades the firmware...

Страница 141: ...faults Resets the CO to factory defaults Switch to Ethernet Mode DS3 Mode for Systems supporting DS3 Switches the CO to the desired mode Export Logs Opens a dialog box enabling you to export the CO Sy...

Страница 142: ...y the Performance Monitoring data in the RT Reset Logs Resets only the Alarm Logs in the RT Reset PM Logs Resets only the Alarm Logs in the RT Switch to Factory Defaults Resets the RT to factory defau...

Страница 143: ...o get distance from the chassis remove the MSPAN connector from the chassis If removal of the MSPAN connector is not possible calibration can be done at any point in the loop including the MDF This po...

Страница 144: ...iagnostic If there are large differences in the line length of the pairs it indicates possibly a short open ground fault or bridge tap If the pair is open in the middles of a loop the length will indi...

Страница 145: ...h pair Follow this procedure to run DELT 1 DELT is service effecting The remote unit must be connected 2 Click on Start Testing button to run the DELT test The Status of the DELT test is indicated to...

Страница 146: ...the AK355 System The screen shot above shows a normal result There should be current flowing between Pair1 and T1and R1 between Pair 2 and T2 and R2 The current flow numbers should be close in value...

Страница 147: ...47 180 0037 002 R01 3 3 11 License The License tab displays the features that are activated for the various units of the AK355 System Click on the CO unit to bring up the Software License dialog box C...

Страница 148: ...1 See the following table for the Features and Values Feature Values Asymmetric 2 2 Mhz Line Powering Activated Thisfeature is activated on the selected slot Not Activated This feature is not activate...

Страница 149: ...AK355 System Installation and User s Guide Positron Access Solutions 149 180 0037 002 R01 Chapter 4 ______________________________________ Technical and Regulatory Specifications...

Страница 150: ...10 Standard Interfaces DS3 12 Number of BNC Ports 2 Per Card Line Code Rate B3ZS 44 736 Mbps 20 ppm Framing C bit Parity or M13 Payload Mode Clear Channel TDM ATM Scrambled ATM Timing Internal or Lin...

Страница 151: ...Watts AK355R and AK355R E units Line Powered by CO Unit or Local Power Input 42 to 56 7 Vds Max Heat Dissipation 60 Watts Provides 48 Vdc 15 Watt output AK355CPS Unit Line Powered by by the AK355RP U...

Страница 152: ...arm Contacts Critical Major Minor SysID Alarm Cutoff Pushbutton Auxiliary alarm inputs 2 Network Management TL1 SNMP EMS or AktinoView DS3 ATM Inband Management Ethernet VLAN Inband Management Regulat...

Страница 153: ...AK355 System Installation and User s Guide Positron Access Solutions 153 180 0037 002 R01 Chapter 5 ______________________________________ Maintenance...

Страница 154: ...ld be replaced as needed Ordering information for fans can be found at the end of this document The filters for the systems should be replaced every six months Care should be taken when replacing filt...

Страница 155: ...AK355 System Installation and User s Guide Positron Access Solutions 155 180 0037 002 R01 Chapter 6 ______________________________________ Safety and Warnings...

Страница 156: ...personnel should service this system The equipment must be connected to a protective ground in accordance with the instructions provided in this manual Improper grounding may result in an electrical s...

Страница 157: ...ould be maintained Particular attention should be given to supply connections other than direct connections to the branch circuit e g use of power strips During installation and service do not connect...

Страница 158: ...te for the normal Positron unit s circuit voltage together with superimposed transients At the time of installation it shall be checked that all multi pair span circuits to be connected together are a...

Страница 159: ...AK355 System Installation and User s Guide Positron Access Solutions 159 180 0037 002 R01 Chapter 7 ______________________________________ Warranty and Customer Service...

Страница 160: ...on customer web portal http portal positronaccess com login asp Positron Sales Pricing Availability 949 258 0545 Positron Technical Support Pre Sales Applications Post Sales Technical Assistance 949 2...

Страница 161: ...AK355 System Installation and User s Guide Positron Access Solutions 161 180 0037 002 R01 Chapter 8 ______________________________________ Positron Products...

Страница 162: ...ernet 45Mbps DS3 and up to 100Mbps Ethernet at CSA Local Powered or Line Powered AK355RP AK355 RT Unit DS3 Ethernet Unit 45Mbps DS3 and up to 100Mbps Ethernet at CSA with Line Power Option AK355R E AK...

Страница 163: ...AK355 System Installation and User s Guide Positron Access Solutions 163 180 0037 002 R01 Appendices...

Страница 164: ...AK355 System Installation and User s Guide Positron Access Solutions 164 180 0037 002 R01 Appendix A ______________________________________ System Software Upgrade...

Страница 165: ...e version 7 Select the corresponding self extracting exe file and store the file in the place of your choice on your PC 8 Extract the files from the self extracting exe file to a location of your choi...