background image

 

 

Part 5 

type 

Finger Print Sensor 

f) 

Customer display:

 Pole mount 2 x 20 VFD display PD-2601

 

or LCD 

pole display PD-7321 or 

2

nd

 LCD Screen:

 LM-2010

 

g) 

Audio amplifier and internal speakers 

h) 

Wireless LAN Adaptor:

 inside back cable cover, IEEE 802.11b/g

 

i) 

UPS Battery: 

2.3 AH 12V lead acid maintenance free battery

 

j) 

2-in-1 Cash Drawer Control Cable: 

Cable CCBLA-238, when added 

to the CR port of the HT-2212 Pro series, can be used to control two 
Posiflex printer drive type cash drawers.

 

k) 

Preload OS: 

Win 2000, Win XP pro or WEPOS.

 

l) 

Cash drawer:

 

Printer (Direct) drive type Posiflex cash drawers. Model 

numbers coded as CR-3100, CR-3200, CR-4000 or CR-4210

 

m) 

Programmable Keyboard:

 Various types of Posiflex programmable 

keyboards. Most recommended: KB-6000, KB-6200 series or KB-6600.

 

n) 

Bar Code Scanner:

 Short range type (near contact) and long range type 

(250 mm for CD-3830) CCD scanners.

 

o) 

POS printer:

 Posiflex 9 pin dot matrix impact printer or Posiflex 

thermal printer of RS232 serial interface, parallel interface,  USB 
interface or even wireless interface.

 

SYSTEM BOX CONTENTS 

When you receive the system box you will find it contains several items: 

HT-2212 Pro system unit with the 12.1” LCD panel integrated on top 

This user’s manual 

Recovery CD for preloaded OS or Posiflex Product Information CD 

for driver utilities without OS 

Optional components installed to system unit as ordered 

Power adaptor with power cord (1 set) 

Содержание HT-2212 Pro Series

Страница 1: ... without limitation loss of data or profits resulting from the furnishing performance or use of this material This information is provided as is and Posiflex Inc expressly disclaims any warranties expressed implied or statutory including without limitation implied warranties of merchantability or fitness for particular purpose good title and against infringement The information in this manual cont...

Страница 2: ...hole system till completely exhausted Repeatedly using it up or improper maintenance reduces the battery life dramatically Always fully recharge the battery at least once every 3 months if the battery is not connected Always disconnect the UPS battery from the system if the system is to be left OFF for more than 72 hours to prevent possible damage Only connect the UPS battery back right before you...

Страница 3: ... ECR and has avoided the wiring spaghetti associated with more traditional PC solutions This Open Standard Architecture ensures that this terminal can use the PC application software and development tools that are now inexpensively available and abundant The terminal is powered by most up to date CPU and provides a color TFT LCD screen with a resistive type touch control panel on sturdy and easily...

Страница 4: ...awers through use of optional cable Modem Ring Up LAN Or Alarm Wake Up The HT 2212 Pro series can be turned on automatically upon an incoming COM port Modem call or LAN status or data packet received on LAN or a preset time day week month Built in UPS function to support the system from intermittent power failure battery itself is an option Accidental power off protection The power switch is safel...

Страница 5: ... CR 3100 CR 3200 CR 4000 or CR 4210 m Programmable Keyboard Various types of Posiflex programmable keyboards Most recommended KB 6000 KB 6200 series or KB 6600 n Bar Code Scanner Short range type near contact and long range type 250 mm for CD 3830 CCD scanners o POS printer Posiflex 9 pin dot matrix impact printer or Posiflex thermal printer of RS232 serial interface parallel interface USB interfa...

Страница 6: ...The whole installation operation of a half length PCI extension card involves cautiously accessing the interior of the system replacing the slot window metal plate applying the card and installing its driver Therefore only a computer expertcan perform this operationon his own risk MAIN CONNECTION AREA The HT series is constructed for very easy maintenance Press inward both plastic buttons at lower...

Страница 7: ... wireless LAN option is ordered with the HT system this option is already installed in the delivery inside the back cable cover with its cable connected to one of the USB port This cable must be disconnected first if installed whenever the back cable cover is opened for any operation UPS BATTERY OPTION When the HT system is installed with the UPS battery the UPS battery is in the carton at deliver...

Страница 8: ...ay monitor However the port for LM 2010 is the VGA connector SIDE MOUNT UPGRADE KIT SD 300 BC 300 KP 200 OPTION When a side mount upgrade kit option SD 300 or BC 300 is ordered with the HT system this option is already installed in the delivery If they were to be later installed or if the side mount upgrade kit is KP 200 they have to be mounted to the right edge of LCD display at the 2 screws poin...

Страница 9: ...lem in application phase When a KB interface barcode scanner is installed in HT 2212 Pro system a connection of a normal PS 2 keyboard or the Posiflex programmable keyboard could become obligatory by some OS Therefore if there will be no keyboard installed for such OS it is advisory to use an USB interface type barcode scanner instead of the PS 2 KB interface type PRINTER OPTION There are many mod...

Страница 10: ...ists in the HDD in top of the system unit Once the software system on HDD collapses it is possible to restore the operating system onto a physically intact HDD with use of the Recovery CD that comes with the preloaded operating system Please follow the instruction from your system integrator for system software restoration Follow the instructions below for operating system recovery only if your sy...

Страница 11: ...cilities to accomplish such a task Therefore installation of an OS into a system without preloaded OS is highly discouraged Posiflex shall not be responsible for any technical support to questions arisen due to non preloaded OS When the 2nd screen is installed on HT 2012H or HT 2212H the operation of a PS 2 interface mouse will be limited in the area of 1st screen Please use an USB interface mouse...

Страница 12: ...s must conform to local safety regulations UPS Battery option General care The UPS battery is consumable beyond product warranty Please definitely observe the alerts in beginning of this manual If the equipment is to be powered off for more than few days please always disconnect the battery from the system Reconnect it and turn on the system to recharge the battery for 1 2 hours every 3 months for...

Страница 13: ...ion Serial Port COM1 For the HT system with the UPS function a COM1 terminator will also be supplied Please always occupy COM1 serial port by a suitable serial device or this terminator If this port is left vacant or connected with something like a mouse the power switch management and the cash drawer control may fail to work correctly An RS232 MODEM is not applicable to this port It is recommende...

Страница 14: ...r On Control The system may also turn on according to some preset conditions such as Modem Ring Up and Alarm Clock Wake Up or LAN Wake Up To utilize Modem Ring Up or Alarm Clock Wake Up function the user should enter the CMOS setup by pressing Del key at system boot up choose for PM Wake Up Events in Power Management Setup and make the Ring Power Up Control enabled for Modem Ring Up or select the ...

Страница 15: ...t Turning this knob up or down changes the brightness of screen display accordingly Display Utility Driver The end user of the HT terminals is not supposed to install the utility drivers personally If an optional preloaded OS is ordered the required driver will be already installed in the preloaded OS However the driver will always be available over our web site http www posiflex com Touch Functio...

Страница 16: ...op Touch the right button in this drawing Any touch on the screen after this action will result in a right button mouse click at the point touched After touching the left button in this drawing the screen touch will resume the left button function This program also controls the beep generated when the touch panel is touched the detail in right button click emulation and also provides touch panel r...

Страница 17: ...d This function will remain operating even after system restart To disable this function you have to pop up this window again and click Disable then Apply and restart the system If system hang due to CPU overheat occurs please review the ventilation condition and environment temperature check if the fan is stuck by contaminants such as dry grease or threads and try to correct the situation when th...

Страница 18: ...t cover Pull the front cover out from this opening to release the left side hook of front cover from the chassis as indicated by the hollow arrow in the picture above Please then pull the bottom side of front cover forward to release the bottom hooks of front cover from the chassis as indicated by hollow arrow in left picture Now pull the left side of front cover down a little to free it from the ...

Страница 19: ...entions must be taken throughout the further cleaning operations below When the main unit is opened there must be no liquid spill no electro conductive material no electric charged device come into the area of the main unit Please also note that not to touch any component or cable inside Please first disconnect every cable from the main unit and turn the LCD panel to straight up position Prepare e...

Страница 20: ...hreads accumulation away from outsides of both ventilation grids on chassis exposed after removal of the front cover as in pictures below and close back the top cover when done 警告使用者 這是甲類的資訊產品 在居住的環 境中使用時 可能會造成射頻干 擾 在這種情況下 使用者會被要 求採取某些適當的對策 T31454 Side Ventilation Grids on Chassis ...

Отзывы: