background image

USER MANUAL :: 

ENGLISH

:: XSTREAM

Содержание XSTREAM

Страница 1: ...USER MANUAL ENGLISH XSTREAM...

Страница 2: ...0 s The same ideas motivate us now The name Poseidon represents constant development and improvement of diving equipment where everything is positioned correctly and everything functions even in the m...

Страница 3: ...Type approvement certificate no 020341 020342 and 020343 is issued by SGS United Kingdom Ltd Unit 202b Worle Parkway Weston super mare BS22 6WA United Kingdom Notified body number 0120 Production qua...

Страница 4: ...ng greater than 21 oxy gen up to 50 Enriched Air Nitrox IP Interstage pressure the pressure existing between the 1st stage and the 2nd stage valve HP High pressure the pressure inside the SCUBA cylind...

Страница 5: ...oxy gen content than 99 95 by volume Xstream Deep models only for use with air or Trimix with a maximum oxygen content of 21 and a maximum Helium content of 77 Xstream Dive and octopus only for use wi...

Страница 6: ...r than 18 m 59 ft or in overhead environment requires special train ing regarding practices equipment physical and medical understanding This manual assumes the reader has some basic knowledge in thos...

Страница 7: ...must be used exclusively with Nitrox or Oxygen and should be kept O2 clean at all times If a Oxygen Deco or Duration regulator is contaminated or used with a contaminated fill then the regulator must...

Страница 8: ...medical effects or even death if used incorrectly Use recognised tables for oxygen exposure Xstream Oxygen EN 144 3 Deco Deco EN 144 3 is approved for oxygen service directly from the box i e it is cl...

Страница 9: ...if it gets lost during the operation the regulator will continue to function but must only be used for immediate ascent In case of a malfunction in the 1st stage causing excessive intermediate pressur...

Страница 10: ...extreme leaktightness Conventional designs are sensitive to wear misalignment and manufacturing precision A ball always finds its correct place Combined with the 2nd stage the enormous capacity of the...

Страница 11: ...r of 0 C 32 F for at least 10 minutes and after wards still be completely unaffected DEEP DEEP90 1 ST STAGE TRIMIX AIR All materials in Xstream Deep are chosen and tested to be optimised for Helium an...

Страница 12: ...d NVR levels less than ASTM G63 Level C 50 mg m2 hydrocarbons The Xstream Oxy90 1st stage is only used on the Mk VI Discovery Rebreather The Xstream Deco was discontinued in 2005 DURATION DURATION EN...

Страница 13: ...e gas by as much as 12 C 22 F under certain conditions Using a long hose requires some basic knowledge in its use and routing to take the full advantages Poseidon does not recommend the use of hose pr...

Страница 14: ...nnection areas with your fingers since fingerprints are a combustible con tamination OXYGEN ALERT PRE DIVE The procedure described below only describes the manner in which the regulator is assembled a...

Страница 15: ...n the knob back half turn When the 2nd stage is pressurised and the servo mechanism engages a maximum of 3 litres of gas vents from the 2nd stage Slow opening of the cylinder valve is the best way to...

Страница 16: ...ck for the regulator being used The mouth region can become numb from cold and you risk loosing the regulator DIVING What is most distinctive about the Xstream is that it is easy to use there aren t a...

Страница 17: ...that the pro tective cap is free from water and debris then mount the protective cap onto the connection The regulator should not be stored in direct sunlight and or at high temperatures Make sure it...

Страница 18: ...stream neck strap surgical cord Poseidon Jetstream 2nd stage and hose EN 250 Poseidon Jetstream 1st stage EN 250 All CE marked or EN 250 designated cylinder valves Yoke clamp All CE marked approved pr...

Страница 19: ...t gas mix Always follow established calculation methods and mixing procedures for mixing a breathable gas These are not des cribed herein WARNING WARNING Approved gas mixes for Xstream Deep If air is...

Страница 20: ...4351 psi Cold water perfor mance Exceeding EN 250 requirements for cold water use Approvals Type Approved acc to EU Direc tive Personal Protective Equipment 89 686 EEC Applicable Performan ce Standard...

Страница 21: ...gical cord Silicone Dismountable w o tools Yes Anatomic Mouthpiece Poseidon AIR 1st stage Flowrate l min 4000 l min 141 scfm Nominal inter stage pres 8 5 bar 123 psi Anti Freeze protec tion Built in T...

Страница 22: ...22 XSTREAM USER MANUAL ENGLISH M I S C E L L A N E O U S EXPLODED VIEWS With over pressure valve built in to the 1st stage No over pressure valve built in to the 1st stage...

Страница 23: ...of the cylinder capa city The diagram above show a calculated graph for Work of Breathing in Joules litre at Qaverage 62 5 litres min The equation behind it is extracted from hundreds of tests from wh...

Страница 24: ...regula tor free flows breaking the surface Check the cracking pressure see sec tion 6 2 If the crack ing pressure is too low it i n c r e a s e s the risk for free flow Have the re gulator cor rectly...

Страница 25: ...room environment made up by materials chosen to expose lowest possible risk x failure effect product and are tested and approved for oxygen use It is strictly prohibited to use the Poseidon Xstream O...

Страница 26: ...ised service loca tions Look for the POSEIDON Authorised Service Center sign SERVICE CENTER AUTHORIZED Because of the robustness and simplicity of the Xstream construction the amount of servicing is k...

Страница 27: ...uct are prohibited Modifications can impair the function of the regulator and transfers the responsibility to the person who does the mo dification Adding decals and other outer means for oxygen Nitro...

Страница 28: ......

Страница 29: ...421 08 V stra Fr lunda SWEDEN t 46 0 31 7342900 f 46 0 31 7342901 www poseidon se Art no 4695 ISSUE 040924 3 WE INTEND TO CONTINUE TO PRODUCE DIVING EQUIPMENT AS LONG AS A SINGLE DROPOFWATERREMAINSINT...

Отзывы: