background image

Generator

  Instruction 

Manual

To learn more about Porter-Cable 

visit our website at:

http://www.porter-cable.com

The Model and Serial No. plate is located on the frame.  Record these

numbers in the spaces below and retain for future reference.

Model No. 

Type 

Serial No. 

IMPORTANT

Please make certain that the person who is to use this equipment

carefully reads and understands these instructions before starting

operations.

Model

BSV750

PROFESSIONAL POWER TOOLS

Copyright © 2000 PORTER-CABLE Corporation

Part No. D24130-023-1

Shown with optional portability kit

Allparts Equipment Inc   1-877-475-5660                

                    www.allpartsinc.com  

Содержание BSV750

Страница 1: ...and retain for future reference Model No Type Serial No IMPORTANT Please make certain that the person who is to use this equipment carefully reads and understands these instructions before starting o...

Страница 2: ...d in section 4442 and maintained in effective working order Spark arresters are also required on some U S Forest service land and may also be legally required under other statutes and ordinances This...

Страница 3: ...ve humidity corrosive environments and materials or other contaminants Expendable items that become worn during normal use such as fuel filters air cleaners spark plugs and engine oil Cosmetic defects...

Страница 4: ...ize this information we use symbols to the right Please read the manual and pay attention to these sections URGENT SAFETY INFORMATION A HAZARD THAT WILL CAUSE SERIOUS INJURY OR LOSS OF LIFE IMPORTANT...

Страница 5: ...rical current could charge conductive surfaces in contact with the generator Exceeding the load capacity of the generator by attaching too many items or items with very high load ratings to it could r...

Страница 6: ...rovide safe operation Tampering with the engine speed adjustment could re sult in overheating of attachments and could cause a fire Spilled fuel and its vapors can become ignited from hot surfaces or...

Страница 7: ...nsporting Generator If generator is equipped with a fuel shut off valve turn the valve to the off position before transporting to avoid fuel leaks If generator is not equipped with a fuel shut off val...

Страница 8: ...ge variations causing damage to voltage sensitive appliances or could result in fire Operation of voltage sensitive appli ances without a voltage surge protec tor RISK OF UNSAFE OPERATION HAZARD HOW T...

Страница 9: ...guarding to prevent injury Contact with moving parts can result in serious injury RISK OF BURN EXPLOSION HAZARD Wear NIOSH approved goggles and protective gloves when handling battery Explosive chemi...

Страница 10: ...ith the generator for use when required by local electrical ordinances Refer to article 250 of the National Electrical Code to clarify any needed grounding information Your local electric com pany or...

Страница 11: ...ian should also install a sub panel to isolate the circuits you would want to use during an emergen cy or electrical power outage Your generator will not be large enough to handle the load of all the...

Страница 12: ...y sen sitive You must fill the engine to the full mark on the dipstick to inactivate this safety device OFF RUN START SWITCH Placed in the START position to start engine and the OFF position to stop e...

Страница 13: ...d result in overheating of attach ments and could cause a fire Never attempt to speed up the engine to obtain more perfor mance Both the output voltage and frequency will be thrown out of standard by...

Страница 14: ...generator Failure to connect and operate equipment in this sequence can cause damage to equipment and will void the warranty on your generator Follow the wattage calculation table in the Wattage Calc...

Страница 15: ...ND FAULT CIRCUIT INTERRUPTER GFCI RECEPTACLE MONTHLY For maximum protection against electrical shock the GFCI should be tested monthly To test 1 Depress the TEST button The RESET button should extend...

Страница 16: ...forming on these parts and causing possible malfunction of the engine Generator 1 Clean the generator as outlined in the Maintenance Section on this manual 2 Check that cooling air slots and openings...

Страница 17: ...or wattage Example a 5000 rated wattage generator 2500 maximum starting wattage DETERMINING WATTAGE REQUIREMENTS Before operating this generator list all of the appliances and or tools that are going...

Страница 18: ...ulb requires only 100 watts to start Most resistive loads will be listed in wattage WATTAGE CALCULATIONS The wattage ratings shown are averages Wattage requirements may vary with different brands of a...

Страница 19: ...00 CAUTION WATTS DEVICES WITH HIGH STARTING INDUCTIVE LOADS RUN WATTS TIMES X START FACTOR DO NOT CONNECT VOLTAGE SENSITIVE ELECTRONIC EQUIPMENT TV SET COMPUTER ETC DIRECTLY TO YOUR GENERATOR IF YOU U...

Страница 20: ...Have an Authorized Service Center replace 4 Repair or replace cord 5 Depress and reset 1 Overload 2 Faulty cords or equipment 1 Reduce load 2 Check for damaged bare or frayed wires on equipment Repla...

Страница 21: ...21 ENG NOTES...

Страница 22: ...hing connected to the generator Be sure a volt amp surge protector is used when sensitive electronic equipment is used such as televisions computers stereos and etc The damage of such equipment withou...