background image

PORTACOOL 

CYCLONE

 

OWNER’S 

MANUAL

PAC2KCYC01, PACCYC02, 

PACCYC03, PACCYC04, 

PACCYC06

Содержание CYCLONE PAC2KCYC01

Страница 1: ...PORTACOOL CYCLONE OWNER S MANUAL PAC2KCYC01 PACCYC02 PACCYC03 PACCYC04 PACCYC06...

Страница 2: ...a should appear wet before starting the fan The water adjustment valve on each Portacool portable evaporative cooler is set at max flow However ensure the knob is turned completely to the right before...

Страница 3: ...st the GFCI GLCI receptacle or breaker monthly to ensure it is functioning properly Remove the plug from the electrical receptacle by pulling on the plug not the power cord Operation near open flames...

Страница 4: ...Adjustable louvers Control panel Control panel Water adjustment valve Water adjustment valve Hose connection Control panel Water adjustment valve Hose connection Hose connection Power cord Power cord...

Страница 5: ...ath Casters Casters Water level sight tube Adjustable louvers Adjustable louvers Control panel Control panel Water adjustment valve Water adjustment valve Hose connection Hose connection Power cord Po...

Страница 6: ...tank may drop suddenly and restart the flow of supply water This is a normal condition as the KUUL evaporative media requires a large amount of water for proper wetting New KUUL evaporative media req...

Страница 7: ...he water adjustment valve and removing the drain plug will accomplish this Once the tank is drained and the power disconnected the KUUL evaporative media may be removed to allow cleaning of the tank w...

Страница 8: ...f damaged If condition persists call electrician 2 Replace motor 1 Move evaporative cooler at least three feet from the wall 2 Replace fan motor 3 Replace capacitor 1 Replace float valve 2 Tighten plu...

Страница 9: ...tank 2 KUUL evaporative media is mildewed or clogged 1 Too much water delivered to KUUL evaporative media 2 Leaking hose 1 Switch boot is too tight REMEDY 1 Drain flush and clean tank 2 Replace KUUL e...

Страница 10: ...aced at the option of Portacool All transportation charges for shipment of the Equipment and or its component parts that are submitted for replacement or repair under this warranty must be borne by th...

Страница 11: ...the water flow with the water adjustment valve Third make sure there is water in the tank It should be allowed to fill before you turn the pump on Q What is the best environment to product the most c...

Страница 12: ...evaporate in a filled tank within two to 10 hours of operation depending on the water capacity of the evaporative cooler ambient conditions temperature and humidity A water source for refilling the ta...

Страница 13: ...be removed before accessing the inside of the evaporative cooler Remove the center set of KUUL evaporative media first by grasping at the top and tilting it out and away from the evaporative cooler Wh...

Страница 14: ...NL CASTER 3 NL CASTER 3 NL CASTER 3 NL LOUVERS FRNTPNL C1 7112 LOUVERS CYC 11 LOUVERS CYC 11 LOUVERS CYC 16 LOUVERS CYC 16 CONTROLS CTRL 2SPD 01 CTRL 2SPD 01 CTRL 2SPD 01 CTRL 2SPD 01 CTRL 2SPD 01 HO...

Страница 15: ...ped envelope to Portacool 711 FM 2468 Center TX 75935 or register online at www portacool com support PRIMARY USE PRIMARY REASON FOR PURCHASE DESCRIBE YOUR PURCHASE Auto Aviation Safety Purchased befo...

Страница 16: ...NOTES...

Страница 17: ...NOTES...

Страница 18: ...NOTES...

Страница 19: ...tive media 711 FM 2468 Center Texas 75935 936 598 5651 www portacool com www theKUULeffect com MANR0002 The manual is available in other languages To download a digital copy please visit www portacool...

Отзывы: