34
Operating Manual
DE
EN
FR
IT
ES
PT
NL
SV
FI
DA
NO
EL
CZ
HU
PL
HR
SR
SK
SL
ET
LT
LV
RO
BG
MK
Vehicle Charge Ports and Vehicle
Plugs
Different vehicle charge ports
A
and vehicle plugs
B
are available depending on the vehicle equipment.
Selecting a Supply Cable
For regular charging with optimum charging speed,
use only the supply cables listed below.
The maximum achievable charging power is up to
11 kW (depending on the type of device, national
regulations, mains supply/domestic connection and
on-board charger).
Supply cables for industrial electrical outlets
NOTICE
Damage to the charger
The charger must only be operated within a temper-
ature range from –30 °C to +50 °C.
e
To prevent overheating during operation, avoid
continuous exposure of the charger to direct
sunlight. If the charger overheats, the charging
power is reduced until the temperature has
returned to the normal range.
e
If the charger is too hot or too cold, allow it to
return slowly to the operating temperature range
and do not actively cool it down or heat it up.
Connection or plug
Standard and designation
IEC 62196-2/
SAE-J1772-2009
Type 1 UL/IEC and type 1/
PSE
IEC 62196-2
Type 2
Information
In Japan and Uruguay
1)
, the charger must only be
operated using a fixed connection (Wallbox mode).
Operation using a household or industrial electrical
outlet (mode 2) is prohibited.
1) Time of printing. Further information is available from
a qualified specialist workshop. Porsche recommends
a Porsche partner as they have trained workshop personnel
and the necessary parts and tools.
NOTICE
Use only supply cables approved for the country you
are in. When driving abroad, always carry the appro-
priate supply cable with you for use in the country
you are visiting.
Only the supply cables listed below are permitted in
the following countries:
Country
Supply cable
Argentina
5, 6, 7, 8, E
Russia, Ukraine
5, 6, 7, 8, C
Abu Dhabi, Israel,
Singapore
5, 6, 7, 8
Electrical socket Plug
Standard and
designation
1
NEMA 14-30
2
NEMA 14-50
3
NEMA 6-30
4
NEMA 6-50
5
IEC 60309-2
CEE 230 V/16 A
6 h
6
IEC 60309-2
CEE 230 V/32 A
6 h
7
IEC 60309-2
CEE 400 V/16 A
6 h