![Pool Technologie PRO DOSING ORP Скачать руководство пользователя страница 22](http://html1.mh-extra.com/html/pool-technologie/pro-dosing-orp/pro-dosing-orp_instructions-for-use-manual_1579402022.webp)
5
3.
ELECTRONICS UNIT
3.1.
First commissioning
The first time you power up the electronics unit, carry out the programming below.
Successive
menus
Possible settings
Navigation
Languages
ENGLISH
•
French
•
English
•
Deutsch
•
Español
•
Italiano
•
Nederlander
•
Portugués
For each menu, select a setting with the buttons,
then confirm with the
OK
button.
ORP setpoint
From 200 to 900 mV, in 10 mV
increments
Prop. range ORP
From 30 to 50 mV, in 10 mV increments
Upper Limit
From (
ORP setpoint
+ 60 mV) to 990 mV,
in 10 mV increments
Lower Limit
From 10 mV to (
ORP setpoint
–
60 mV),
in 10 mV increments
pH setpoint
From 6.8 to 7.6, in increments of 0.1
pH Prop. Range
From 0.05 to 0.15, in increments of
0.05
Upper Limit
From (
pH setpoint
+ 0.2) to 8, in
increments of 0.1
Lower Limit
From 6 to (
pH setpoint
- 0.2), in
increments of 0.1
Date
01/01/01
Day/Month/Year
Time
XX:XX
Hour/Minute
Software Version
XX.XX
None (read-only display for a few
seconds)
3.2.
LEDs
Colour
Status
Possible meanings
Green
Continuously on
Electronics unit on
Flashing
•
Chlorine injection in progress
•
pH corrector injection in progress
Red
Continuously on
•
Electronics unit powered off
•
Alert activated
Flashing
Alarm activated
I
BEFORE FIRST START-UP, carefully read the manual provided with the amperometric probe. This manual contains
instructions that are essential for successful start-up and optimal operation of the equipment. It is imperative
that you follow and strictly comply with all of this manual.
Содержание PRO DOSING ORP
Страница 36: ......