10
2.7.
pH regulation
2.7.1.
Manual injection
Menu
Functions
Possible
settings
Setting
by default
Instructions
pH regulation
Manual injection
•
Primes the pump and fills
the semi-rigid pipes
•
pH corrector injection
•
Means of checking that the
pump is working properly
From 1 to 59, in
1 min
increments
10 min
•
To start injecting:
Confirm
the
selected
setting.
(The
pump
is
running, and the timer
countdown is displayed in
real time).
•
To pause,
and to restart injection:
Press
OK
.
•
To stop injection:
Press
.
2.7.2.
Activation/deactivation of pH regulation
Menu
Possible settings
Default setting
pH regulation
Mode XXX
•
ON
(to activate)
•
OFF
(to disable)
ON
2.7.3.
Calibration of the pH measurement
Menu
Possible settings
Default setting
pH regulation
Adjustment
From 6.5 to 7.5, in increments of 0.1
7
2.7.4.
Calibrating the pH probe
→
The original pH probe provided is already calibrated. It is therefore not necessary to calibrate the pH probe when
putting the equipment into service for the first time.
I
However, the pH sensor must be calibrated:
-
at the start of each season when the equipment is re-commissioned,
-
each time the probe is replaced.
1)
Open the pH 7 and pH 10 calibration solutions (use only single-use calibration solutions).
2)
Close the measuring chamber’s 2 supply valves.
3)
If the probe is already installed:
Take the probe out of the measuring chamber, without disconnecting the probe.
If the probe is not already installed:
Connect the probe to the electronics unit.
4)
Go to the ‘
pH Regulation - Calibration
’ menu.