4
2.
ELECTRONICS UNIT
2.1.
First commissioning
The first time you power up the electronics unit, carry out the programming below.
Successive
menus
Possible settings
Navigation
Languages
ENGLISH
•
French
•
English
•
Deutsch
•
Español
•
Italiano
•
Nederlander
•
Portugués
For each menu, select a setting with the buttons,
then confirm with the
OK
button.
CL setpoint
From 0.5 to 8 ppm, in increments of 0.1
ppm
Prop. range CL
From 0.1 to 0,3 ppm, in increments of
0.1 ppm
Upper Limit
From (
CL setpoint
+ 0.2 ppm) to 10 ppm
in increments of 0.1 ppm
Lower Limit
From 0.1 ppm to (
CL setpoint
- 0.2
ppm), in increments of 0.1 ppm
pH setpoint
From 6.8 to 7.6, in increments of 0.1
pH Prop. Range
From 0.05 to 0.15, in increments of
0.05
Upper Limit
From (
pH setpoint
+ 0.2) to 8, in
increments of 0.1
Lower Limit
From 6 to (
pH setpoint
- 0.2), in
increments of 0.1
Date
01/01/01
Day/Month/Year
Time
XX:XX
Hour/Minute
Software Version
XX.XX
None (read-only display for a few
seconds)
I
BEFORE FIRST START-UP, carefully read the manual provided with the amperometric probe. This manual contains
instructions that are essential for successful start-up and optimal operation of the equipment. It is imperative
that you follow and strictly comply with all of this manual.