PM605A Hardware Instruction Manual
17
2.8 Optional Accessories
2.8.1 Separated 300V DC Voltage (Optional)
Output range: 0
~
300V;
Output resolution and min. adjustment step: 1mV;
Accuracy:
≤±0.1%
(The relative error is no more than ±0.1% within 30V
~
300V. The absolute error
is no more than ±30mV within 0
~
30V.)
Stability:
≤±0.05%/3min
;
Max. output power: 30W; Max load current: 100mA;
Ripple content:
≤0.2%
2.9 Fault Protection
Current output overload protection function: when the voltage output is short circuit or overloaded,
the kit will make alarm and the light flash.
Over hot protection function: when it is over hot, the kit will make alarm and the light will flash.
After alarm, it will stop output automatically.
Auto current open circuit protection and current open circuit inspection function.
When the DC voltage input is connected with AC voltage output incorrectly, the kit will make alarm
and the light flash.