Ponovo PAV120Bip Скачать руководство пользователя страница 1

PAV120BIP Power Amplifier User Manual 

 

 

PONOVO POWER CO., LTD

 

 

No. 139 Jinghai Third Road, BDA, Beijing, China, 100176 

 

Office 

TEL. +86 (10) 59089666 

 

E-Mail 

[email protected] 

 

Website 

www.relaytest.com / www.ponovo.com.cn 

 

 

 

 

PAV120Bip 

POWER AMPLIFIER USER MANUAL 

 

 

 

 

 

VERSION:   

 

 

 

PAV120Bip-AE-1.40

 

DATE:   

 

 

 

 

JULY 2020  

 

 

 

 

 

This manual is the publication of PONOVO POWER CO.,LTD. Any form of copy should 

obtain the consent of it. 

 

The manual represents the technology status at publication time. The product information, 
directions and all  technical specifications do not have contract binding. The company 

subjects to changing the technical and configuration information without notice. The 
company is not responsible for possible errors occurred in the manual. 

 

Содержание PAV120Bip

Страница 1: ...0Bip AE 1 40 DATE JULY 2020 This manual is the publication of PONOVO POWER CO LTD Any form of copy should obtain the consent of it The manual represents the technology status at publication time The p...

Страница 2: ...and Weight 12 2 4 Technical Specifications 12 4 Functions and Features 13 4 1 Basic Principle 13 4 2 Functions and Features 13 4 3 PAV120Bip Front Panel 15 4 4 PAV120Bip Rear Panel 17 5 How to Use Amp...

Страница 3: ...PAV120BIP Power Amplifier User Manual 3 7 Parameter definition 25...

Страница 4: ...m shaking 4 Generally it s not necessary to depress high power button high power button light should be off also 5 Never operate live signal and load wires with voltage or current output to protect th...

Страница 5: ...and operate the equipment in the place having explosive gas or water vapor 14 The 500V dangerous voltage can be in the equipment and please don t remove the cover by yourself 15 Please contact the ma...

Страница 6: ...trument is grounded through the Protective Earth lead of the power cord To avoid electric shock it is essential to connect the earth terminal of power cord to the Protective Earth terminal before any...

Страница 7: ...e instrument have it inspected by qualified service personnel before further operations Any maintenance adjustment or replacement especially to circuits or accessories must be performed by authorized...

Страница 8: ...Environment The best condition for optimal measurement is 5 to 40 less than 2 hour changing 20 to 80 RH and the instrument should not be placed towards the air outlet Electrostatic Prevention Operate...

Страница 9: ...al area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense 2 General Description The power amplifier for digital simulator i...

Страница 10: ...r User Manual 10 PAV120Bip is specially designed for R D of power system simulation It is adapt to various capacitive and inductive load There are 6 phase voltage outputs with max 120VRms per phase an...

Страница 11: ...Storage temperature 25 70 C Related humidity 20 RH 85 RH Pressure 86 kPa 106kPa EMC Emission IEC 61000 3 2 3 EMC immunity IEC 61000 4 2 3 4 5 6 11 Safety IEC EN 61010 1 2010 UL 61010 1 2012 CAN CSA C2...

Страница 12: ...put power 60VA 120V output Input signal Gain Standard 0 5V RMS 7 07Vpek Gain 25V V Option 1 0 7 07V RMS 10Vpek Gain 20V V Option 2 0 11 31V RMS 16Vpek Gain 12V V Voltage accuracy 0 1 5V 120V Voltage t...

Страница 13: ...ure is too high It will resume working when it is cooled down to a reasonable degree e Cooling fan when the temperature is quite low the fan will work at a low speed for prolonging the fan s life span...

Страница 14: ...ights After overload and short circuit disappear it restores to working status 4 2 3 Pause control function The pause button on the front panel can cut off the amplifier s signal output The Pause indi...

Страница 15: ...4 3 PAV120Bip Front Panel 1 3 4 5 6 2 1 Ground protection 2 Amplifier input for the low level for example the output of RTDS etc Please refer to definition below with the internal pins 3 Voltage outp...

Страница 16: ...PAV120BIP Power Amplifier User Manual 16 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 Definition Pin Lead definition 1 U1 2 U1 3 U2 4 U2 7 U3 8 U3 12 U4 13 U4 16 U5 17 U5 18 U6 19 U6...

Страница 17: ...PAV120BIP Power Amplifier User Manual 17 4 4 PAV120Bip Rear Panel 1 3 2 1 Power socket 2 Ventilation 3 Ventilation...

Страница 18: ...ectly turn on the amplifier the power supply indicator will light and run indicator will flicker It indicates the amplifier works normal 5 3 Voltage Output First press Pause button and connect the vol...

Страница 19: ...f amplifier and load lastly turn off power 5 5 Amplifier Test Items Before putting into market the amplifier is required to have strictly inspections The test items are function inspection linearity l...

Страница 20: ...stance Users should take the consequence without prior notice to manufacturer or agent Pictures for reference only 6 1 Soft Bag for Test Leads The amplifier Wiring Accessory Package contains the follo...

Страница 21: ...mplifier with power supply socket PONOVO will provide relevant plug socket according to different countries NOTE D03 Adapter is mainly used in German Finland France Norway Sweden Poland South Korean A...

Страница 22: ...unt 1 piece Earthing lead connects the amplifier with ground to ensure kit safety Notes In order to avoid static induction users should connect the equipment with ground reliably before testing 4 Cont...

Страница 23: ...PAV120BIP Power Amplifier User Manual 23 5 Crocodile clip SAW0208 Crocodile clips Amount 8 pieces Crocodile clip is connected with the current cable...

Страница 24: ...Transportation Case The large size case with wheels is designed for heavy transport stress with folding hand it is made of fireproof materials and smooth rolling rubber tires SAC0105 Transportation ca...

Страница 25: ...Relative error 100 ue ulationval Outputcalc ue ulationval outputcalc tputvalue Measuredou 4 Linearity 2 max ror negativeer rror positivvee Max 5 Voltage amplifier load stability No load voltage U1 50...