Ponovo PAC60Bi Скачать руководство пользователя страница 1

                                               PAC60Bi (PAC60Ci)/PAV120Bi POWER AMPLIFIER USER MANUL

 

 
 

 

PONOVO POWER CO., LTD

 

 

No. 139 Jinghai Third Road, BDA, Beijing, China, 100176 

 

Office 

TEL. +86 (10) 59089666 

 

E-Mail 

[email protected] 

 

Website 

www.relaytest.com / www.ponovo.com.cn 

 

 
 

PAC60Bi (PAC60Ci)/ PAV120Bi 

POWER AMPLIFIER USER MANUAL 

 
 

 
VERSION: 

 

 

 

 

PAC60Bi (PAC60Ci)/ PAV120Bi-AE-1.10

 

DATE: 

 

 

 

 

 

16/01/2017  

 

 
 
 
 

This manual is the publication of PONOVO POWER CO.,LTD. Any form of copy should obtain the 
consent of it. 

 

The manual represents the technology status at publication time. The product information, 
directions and all technical specifications do not have contract binding. The company subjects to 
changing the technical and configuration information without notice. The company is not 
responsible for possible errors occurred in the manual.

 

 
 
 
 

 

Содержание PAC60Bi

Страница 1: ...PAC60Bi PAC60Ci PAV120Bi AE 1 10 DATE 16 01 2017 This manual is the publication of PONOVO POWER CO LTD Any form of copy should obtain the consent of it The manual represents the technology status at...

Страница 2: ...60Ci Amplifier 6 30A RMS 450VA phase 4U 3 phase 380VAC 10 47 63Hz PAV120Bi Amplifier 6 x 120v RMS 60VA phase 4U 3 phase 380VAC 10 47 63Hz Accessories PAP02 Optional accessories Three phase main power...

Страница 3: ...keep dry and protect from shaking 5 Generally it s not necessary to depress high power button high power button light should be off also 6 Never operate live signal and load wires with voltage output...

Страница 4: ...14 2 1 Basic Principle 14 2 2 Function 14 2 3 High Power Current Output 15 2 4 Front and Rear Panels 16 2 5 Terminal Definition of Rear Panel 18 3 PAV120Bi Voltage Amplifier 19 3 1 Basic Principle 19...

Страница 5: ...PAC60Bi PAC60Ci PAV120Bi POWER AMPLIFIER USER MANUAL 5 1 Main Technical Performance 1 1 Dimension and Weight 1 1 1 Dimension...

Страница 6: ...PAC60Bi PAC60Ci PAV120Bi POWER AMPLIFIER USER MANUAL 6 1 1 2 PAC60Ci 1 1 3 PAV120Bi...

Страница 7: ...PAC60Bi PAC60Ci PAV120Bi POWER AMPLIFIER USER MANUAL 7 1 1 4 PAD24...

Страница 8: ...PAC60Bi PAC60Ci PAV120Bi POWER AMPLIFIER USER MANUAL 8 1 1 5 PSS01B...

Страница 9: ...PAC60Bi PAC60Ci PAV120Bi POWER AMPLIFIER USER MANUAL 9 1 1 6 PSS02B or PSS05B...

Страница 10: ...PAC60Bi PAC60Ci PAV120Bi POWER AMPLIFIER USER MANUAL 10 1 1 7 PAT01...

Страница 11: ...e with care during transportation 1 4 Power Input Power supply 380 420V phase phase Type Item PAC60Bi PAC60Ci PAV120Bi Power supply 3 phase 380V 10 50 60Hz 3 phase 380V 10 50 60Hz Supply capacity 2500...

Страница 12: ...Current Precision 0 2 0 5A 60A 0 2 0 5A 30A Linearity 0 2 Phase Precision 0 2 Distortion 0 2 Frequency Range DC 5kHz 1dB Step Response 20 s Input output Delay 20 s 1 7 PAV120Bi Voltage Amplifier Outpu...

Страница 13: ...C60Bi PAC60Ci PAV120Bi POWER AMPLIFIER USER MANUAL 13 1 8 Current Voltage Amplitude Display There are 3 and a half digits of true RMS values displayed for output current voltage with the precision of...

Страница 14: ...e of the amplifier is quite low the fan will work at low speed for it s better for prolonging the service life and reducing the operation noise of the fan 2 2 Function 1 The differential input circuit...

Страница 15: ...utions 1 Generally it s not necessary to activate the high power output function because it may cause extra heat generated from amplifier 2 High power output function must be inactivated as soon as th...

Страница 16: ...PAC60Bi PAC60Ci PAV120Bi POWER AMPLIFIER USER MANUAL 16 2 4 Front and Rear Panels PAC60Bi Front and Rear Panels...

Страница 17: ...PAC60Bi PAC60Ci PAV120Bi POWER AMPLIFIER USER MANUAL 17 PAC60Ci Front and Rear Panels...

Страница 18: ...n Overheat alarm signal output Voltage output overload short circuit alarm signal Pause signal output Inverse time limit signal output Control Signal Input Terminal No 1 2 3 4 5 6 Output Mode COM Func...

Страница 19: ...ow speed if amplifier temperature is certain low which is benefit for prolonging its service life and reducing working noise 3 2 Function 1 The differential input circuit can reduce the influence of t...

Страница 20: ...20 Overheat alarm light on the front panel will turn on 5 3U0 accumulation function Ua Ub and Uc can be added up to form a 3U0 signal to be outputted via Ud channel 6 Two gain options User can accord...

Страница 21: ...PAC60Bi PAC60Ci PAV120Bi POWER AMPLIFIER USER MANUAL 21 3 3 Front and Rear Panels...

Страница 22: ...USER MANUAL 22 3 4 Terminal Definition of Rear Panel Terminal No 0 1 2 3 4 5 6 7 8 9 A B C Function Definition Low pass Filtering 12V Low pass filtering NC Test signal input Test signal GND Test contr...

Страница 23: ...test signal of each phase output to the inverse time limit control which should be activated by biggest output current Initial selection for current output with time limit For 1ACT 10A For 5ACT 20A T...

Страница 24: ...PAC60Bi PAC60Ci PAV120Bi POWER AMPLIFIER USER MANUAL 24 4 2 PAT01 Front and Rear Panels PAT01 Front Panel PAT01 Rear Panel...

Страница 25: ...23 White Blue 2 Voltage amplifier s rectification signal of group I 24 White Blue 3 Amplifier s rectification control of group I 25 White Blue 4 Current amplifier s rectification signal of group II 26...

Страница 26: ...t output s test signal 35 White Blue 6 Ia current output s test signal 36 White Blue 7 Ia current output s test signal 37 White Blue 8 Ib current output s test signal 38 White Blue 9 Ib current output...

Страница 27: ...anel or operate the remote control to send the pause signal connect current voltage output terminals to corresponding terminals of the tester respectively and then inactivate the pause function and in...

Страница 28: ...AV120Bi POWER AMPLIFIER USER MANUAL 28 5 4 Amplifier Off If you want to turn off the amplifier please terminate the simulator signal input pull off all wires between amplifier and loads and turn off t...

Страница 29: ...nd high power output running test before delivery The test items include function test linearity load stability total harmonic distortion maximum output power amplitude and frequency characteristic in...

Страница 30: ...s are shown as follow 1 Standard Chassis Dimension W D H 600mm 800mm 1600mm 600mm 800mm 1800mm Weight 50kg 60kg Maximum load of caster 300kg 2 PAP 02B Power Control Device Input 3 phase 380V 10 50Hz P...