Ponovo PA60BI Скачать руководство пользователя страница 1

 

 

 
 
 
 
 

PONOVO POWER CO., LTD 

 

No. 139 Jinghai Third Road, BDA, Beijing, China, 100176 

 

Office 

TEL. +86 (10) 59089666 

 

E-Mail 

[email protected] 

 

Website 

www.relaytest.com / www.ponovo.com.cn 

 

 
 

 

PA60BI 

POWER AMPLIFIER USER MANUAL 

 
 

 

 

 

VERSION:   

 

 

 

PA60BI-AE-1.20 

DATE:   

 

 

 

 

MARCH 2021   

 
 
 
 

This manual is the publication of PONOVO POWER CO.,LTD. Any form of copy should 
obtain the consent of it. 

 

The manual represents the technology status at publication time. The product information, 
directions and all technical specifications do not have contract binding. The company 
subjects to changing the technical and configuration information without notice. The 
company is not responsible for possible errors occurred in the manual. 

 

Содержание PA60BI

Страница 1: ...2021 This manual is the publication of PONOVO POWER CO LTD Any form of copy should obtain the consent of it The manual represents the technology status at publication time The product information dir...

Страница 2: ...3 High Power Output 15 5 Function and Features of Voltage Amplifier 17 5 1 Basic Principle 17 5 2 Function 17 6 Panels 19 6 1 Front Panel 19 6 2 Rear Panel 20 6 3 Terminal Definition 21 7 How to Use...

Страница 3: ...shaking 4 Generally it s not necessary to depress high power button high power button light should be off also 5 Never operate live signal and load wires with voltage or current output to protect the...

Страница 4: ...and operate the equipment in the place having explosive gas or water vapor 14 The 500V dangerous voltage can be in the equipment and please don t remove the cover by yourself 15 Please contact the man...

Страница 5: ...authorized by local country could be used Ground The Instrument The instrument must be grounded safely with the supplied ground cable Observe All Terminal Ratings To avoid fire or shock hazard observ...

Страница 6: ...ther operations Any maintenance adjustment or replacement especially to circuits or accessories must be performed by authorized personnel Keep Well Ventilation Inadequate ventilation may cause increas...

Страница 7: ...d towards the air outlet Electrostatic Prevention Operate in an electrostatic discharge protective area environment to avoid damages induced by static discharges Always ground both the internal and ex...

Страница 8: ...ul interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the ins...

Страница 9: ...e available to all kinds of capacitive inductive and resistive loads Generally power amplifier consists of two types of amplifiers linear power amplifier and switching power amplifier The linear power...

Страница 10: ...total power It is suggested the total power supply by PAP02 should be not less than 5 times of the total power of all the amplifiers installed on the same panel It is suggested power on each amplifie...

Страница 11: ...ounding conditions No dust vibration or serious electromagnetic field interferes The equipment is not recommended to be used out of laboratory Avoid the equipment to be used online out of laboratory i...

Страница 12: ...ndard 0 7 07V RMS 10Vpek Gain 9A V Option 0 11 31V RMS 16Vpek Gain 6A V Input signal Digital optional Support Aurora protocol Current accuracy 0 2 0 5 60A Current typical accuracy 0 1 Differential inp...

Страница 13: ...t Input signal Gain Standard 0 7 07V RMS 10Vpek Gain 20V V Option 0 11 31V RMS 16Vpek Gain 12V V Voltage accuracy 0 1 5V 120V Voltage typical accuracy 0 05 Differential input impedance 20k Harmonic di...

Страница 14: ...PA60Bi Power Amplifier User Manual 13 3 6 Digital Display of Voltage Current Output The RMS of current or voltage output can be displayed in real time on the panel...

Страница 15: ...ion detection circuit 4 Protection circuit by which the amplifier can be terminated when its temperature is too high and will resume working when it is cooled down to a reasonable degree 5 Cooling fan...

Страница 16: ...eat alarm light on the front panel will be on 4 3 High Power Output With high power control button is pressed after several seconds the high power control button light will be on By then the current a...

Страница 17: ...A60Bi Power Amplifier User Manual 16 4 Never apply the high power output function when DC current is produced 5 Never switch to off the high power output function when amplifier is producing any outpu...

Страница 18: ...rtion detection circuit When the overload or short circuit situation disappears the amplifier will resume to work automatically 4 Temperature protection circuit It will terminate the amplifier as soon...

Страница 19: ...isappears the amplifier can resume to work automatically If overload or short circuit occurs the amplifier will be terminated automatically and the overload alarm light on the front panel will turn on...

Страница 20: ...ge output will be shown based on the switch 5 High power button Press it and light in red to output high power 6 Pause button Press it and light in red The current and voltage output will be paused Th...

Страница 21: ...h the current input of the test object 12 Voltage output It is connected with the voltage input of the test object 13 Contact signal output Please refer to the terminal definition below 14 Control sig...

Страница 22: ...signal output Voltage output overload short circuit alarm signal Pause signal output Inverse time limit signal output Control Signal Input Terminal No 1 2 3 4 5 6 Output Mode COM Function Definition...

Страница 23: ...Definition VA signal input VA signal input VB signal input VB signal input VC signal input VC signal input VZ signal input VZ signal input Current Signal Input Terminal No 1 2 3 4 5 6 Channel IA IB IC...

Страница 24: ...that power supply is normal and polar of input signal wires is correct before energizing the amplifier When all things are ready turn on the power of PAP02 first and then turn on the power on amplifi...

Страница 25: ...he high power function for a short time Inactivate the high power function as soon as this high current test was done Note 1 Normally high power button is not activated high power switch light is off...

Страница 26: ...ower output running test before delivery The test items include function test linearity load stability total harmonic distortion maximum output power amplitude and frequency characteristic input outpu...

Страница 27: ...e Amount 4 pieces The current cables to connect the amplifier output to other safety sockets of generally the current parts Colour coded voltage cables SAW0202 colour coded voltage cable Amount 5 piec...

Страница 28: ...rs are shown as follow 10 1 Standard Chassis Dimension W D H 600 800 1800mm Weight 50kg Maximum load 300kg 10 2 PAP 02B Power Control Device Input 3 phase 380V 10 50Hz Protection function Open phase s...

Страница 29: ...02 please carefully check if the power on each amplifier is turned off 1 Turn on the power of PAP02 first 2 Turn on the individual amplifier power in testing 3 After testing is finished please turn of...

Отзывы: