Before placing the pump into operation the operator must make sure that
• the pump and all other components were not damaged during
the carriage.
• the information on the nameplate concerning equipment group
and category, zone, temperature class and explosion group
accords with the permissible use in the particular hazardous
location.
• the air temperature of the ambience of the pump is observed.
• the maximum temperature of the pumping media is not
exceeded.
• +60°C continuous operation
• +80°C short-time operation (operating time max. 1 h)
• pump hose, clamping rings and connecting sockets are mounted properly
and the pump hose is greased sufficiently with Ponndorf special grease
(as described in chapter 6.4).
In case of any discrepancies the pump must not be placed into operation!
While placing the pump into operation the characteristics (pump speed, pressure)
which are prescribed in the manual and on the nameplate must not be exceeded.
3.4
Qualification and training of personnel
The technical personnel responsible for operation, maintenance, inspection and
installation must be qualified for this work. Fields of responsibility, competencies and
the supervision of the personnel have to be exactly regulated by the operator. If the
personnel is inadequately skilled it must be trained and instructed. If necessary, this
may be effected by order of the operator by the manufacturer/supplier.
Furthermore the operator has to make sure that the personnel did absolutely catch
the contents of the operation manual.
3.5
Dangers in case of non-observance of the safety instructions
Non-observance of the safety instructions can endanger people, environment and
equipment and can result in losing any claim for damages.